EUVIMEDEUVIMED entdecken
VergleichsstudieOpen Access · CC BY 4.0

Biomechanical Effects of Two Types of 3D ‐Printed Prosthesis Reconstruction After Single‐Segmental Total En Bloc Spondylectomy: A Finite Element Analysis

Jiasheng Chen iD, Ben Wang, Yang Luo, Xiang Li, Yanchao Tang, Zihe Li, Hua Zhou, Panpan Hu iD, Xiaoguang Liu, Zhongjun Liu, Feng Wei iD

Orthopaedic Surgery · 2026-07 · 18 (7) · 1437-1447

DOI: 10.1111/os.70336 ↗

Kurz gefasst

Vergleichsstudie in der Zeitschrift Orthopaedic Surgery, online erschienen am 21.05.2026. Verfasst von Jiasheng Chen und 10 weiteren Autor:innen. Beteiligte Einrichtung: Department of Orthopaedics, Peking University Third Hospital, Beijing, China. Hauptthemen laut MEDLINE: Printing, Three-Dimensional, Lumbar Vertebrae, Prosthesis Design, Spinal Neoplasms. Die Arbeit nennt 39 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: National Key Research and Development Program of China, Peking University Third Hospital.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Total en bloc spondylectomy (TES) has emerged as an effective surgical intervention for spinal tumor management. The selection of prosthesis for spinal reconstruction significantly influences patient's postoperative outcomes. This study aims to analyze and compare the biomechanical effects of two types of 3D‐printed prostheses and titanium mesh cage (TMC) after TES.

Methods

An intact finite element model (FEM) of L1–L5 segment was developed and validated for simulation. Three L3 TES models were constructed. Model A utilized a 3D‐printed prosthesis with an artificial pedicle, model B employed a stand‐alone 3D‐printed prosthesis, and model C used a TMC. Following parameters were recorded and analyzed to evaluate the biomechanical effects of the three models: (1) the range of motion (ROM), (2) stress of the internal fixation systems, and (3) stress of the L2 inferior endplate and L4 superior endplate.

Results

The ROMs of all three models were significantly restricted in all directions. Compared with TMC, the implantation of 3D printed prosthesis significantly enhanced spinal stability during extension. The ROMs of models A and B were significantly lower than that of model C during extension, decreasing by 15.2% and 36.4%, respectively. The use of 3D‐printed prosthesis for anterior column reconstruction could reduce the stress of prosthesis itself and adjacent endplates. Compared with model C, the maximal decrease in the stress of the endplate of models A and B was 41.5% during flexion and 49.1% during right lateral bending, respectively. In all directions, the stress of the prosthesis was largest in model C, followed by model A and smallest in model B, with statistically significant differences observed.

Conclusion

After single‐segmental TES, 3D‐printed prosthesis with favorable endplate matching could obtain better biomechanical effects, thereby reducing the risk of internal fixation failure and increasing the postoperative spinal stability.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Printing, Three-DimensionalLumbar VertebraeProsthesis DesignSpinal NeoplasmsProstheses and ImplantsPlastic Surgery ProceduresFinite Element AnalysisHumansBiomechanical PhenomenaRange of Motion, ArticularTitaniumSurgical Mesh

Stichwörter der Autor:innen

TESTMC3D‐printed prosthesisbiomechanicsfinite element analysis

Substanzen

Titanium

Autor:innen und Institutionen

  • Department of Orthopaedics, Peking University Third Hospital, Beijing, China.
  • Ministry of Education, Engineering Research Center of Bone and Joint Precision Medicine, Beijing, China.
  • Beijing Key Laboratory of Spinal Disease Research, Beijing, China.

ORCID-Profile: Jiasheng Chen, Panpan Hu, Feng Wei

Förderung

  • National Key Research and Development Program of China
  • Peking University Third Hospital

Zitieren

APA

Chen, J., Wang, B., Luo, Y., Li, X., Tang, Y., Li, Z., Zhou, H., Hu, P., Liu, X., Liu, Z., & Wei, F. (2026). Biomechanical Effects of Two Types of 3D ‐Printed Prosthesis Reconstruction After Single‐Segmental Total En Bloc Spondylectomy: A Finite Element Analysis. Orthopaedic Surgery, 18(7), 1437-1447. https://doi.org/10.1111/os.70336

Vancouver

Chen J, Wang B, Luo Y, Li X, Tang Y, Li Z, et al. Biomechanical Effects of Two Types of 3D ‐Printed Prosthesis Reconstruction After Single‐Segmental Total En Bloc Spondylectomy: A Finite Element Analysis. Orthopaedic Surgery. 2026;18(7):1437-1447. doi:10.1111/os.70336

BibTeX
@article{Chen2026,
  author = {Chen, Jiasheng and Wang, Ben and Luo, Yang and Li, Xiang and Tang, Yanchao and Li, Zihe and Zhou, Hua and Hu, Panpan and Liu, Xiaoguang and Liu, Zhongjun and Wei, Feng},
  title = {Biomechanical Effects of Two Types of 3D ‐Printed Prosthesis Reconstruction After Single‐Segmental Total En Bloc Spondylectomy: A Finite Element Analysis},
  journal = {Orthopaedic Surgery},
  year = {2026},
  volume = {18},
  number = {7},
  pages = {1437--1447},
  doi = {10.1111/os.70336}
}
Kostenlos starten →