EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Correlation Between Functional Scores and Objective Gait Parameters Following Rotating Hinge Knee Megaprosthesis Reconstruction

Meng-Yu Chen iD, Ming-Yong Gu, Sheng-Rui Chu, Chong Li, Xue-Fei Fu, Kuan Zhang, Ji-Zhou Zeng, Yan-Cheng Liu

Orthopaedic Surgery · 2026-05 · 18 (5) · 1042-1053

DOI: 10.1111/os.70300 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Orthopaedic Surgery, online erschienen am 26.03.2026. Verfasst von Meng-Yu Chen und 7 weiteren Autor:innen. Beteiligte Einrichtung: Department of Bone and Joint Surgery, Beijing Luhe Hospital, Capital Medical University, Beijing, China. Hauptthemen laut MEDLINE: Gait, Arthroplasty, Replacement, Knee, Knee Prosthesis. Die Arbeit nennt 39 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Tongzhou district science technology foundation Beijing, China, Science and Technology Program of Jinan Health Commission, Wu Jieping Foundation.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objective

Although the Musculoskeletal Tumor Society (MSTS) score, Toronto Extremity Salvage Score (TESS), and Knee Society Score (KSS) are widely used for postoperative functional evaluation in patients undergoing rotating hinge knee (RHK) megaprosthesis reconstruction, their accuracy in reflecting objective gait performance remains uncertain. The study aimed to analyze the correlations between these scoring systems and gait parameters.

Methods

This retrospective study included 21 patients who underwent RHK between April 2023 and April 2025. At one‐year follow‐up, functional outcomes were assessed using MSTS, TESS, and KSS. Gait parameters were collected using the Intelligent Device for Energy Expenditure and Activity (IDEEA v3.1, MiniSun LLC). All functional assessments were completed on the same day as the gait analysis. Linear regression analyzed correlations between each scoring system and gait parameters. Friedman and Wilcoxon signed‐rank tests compared median coefficients of determination across scoring systems. Stepwise multiple linear regression was used to examine the relationships between the scoring system subitems and gait parameters.

Results

Significant correlations were observed between all three scoring systems and multiple gait parameters after RHK ( p < 0.05). The TESS had a significantly greater median R 2 than did the MSTS score and KSS ( p < 0.05), especially for walking velocity ( R 2 = 0.76), step length ( R 2 = 0.75), initial contact phase ( R 2 = 0.65), and stride length ( R 2 = 0.58). Multiple linear regression analysis revealed that the MSTS “walking” and KSS “function” subitems independently or jointly predicted key gait parameters, including walking velocity, step length, and cadence ( R 2 > 0.48).

Conclusions

All three scoring systems showed correlations with multiple key gait parameters in patients who underwent RHK. However, TESS demonstrated stronger and more consistent correlations and therefore appeared to be a more representative score of gait recovery.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

GaitArthroplasty, Replacement, KneeKnee ProsthesisHumansRetrospective StudiesFemaleMaleMiddle AgedAgedGait AnalysisAdultRecovery of Function

Stichwörter der Autor:innen

IDEEAfunctional scoregait analysismegaprosthesis

Autor:innen und Institutionen

  • Department of Bone and Joint Surgery, Beijing Luhe Hospital, Capital Medical University, Beijing, China.
  • Department of Bone and Soft Tissue Oncology, Tianjin Hospital, Tianjin, China.
  • Department of Sports Medicine, Third People's Hospital of Jinan City, Jinan City, Shandong Province, China.
  • Tianjin Medical University, Tianjin, China.
  • Department of Orthopedics, Provincial People's Hospital, Hefei, China.
  • School of Biomedical Engineering, Capital Medical University, Beijing, China.

ORCID-Profile: Meng-Yu Chen

Förderung

  • Tongzhou district science technology foundation Beijing, China
  • Science and Technology Program of Jinan Health Commission
  • Wu Jieping Foundation

Zitieren

APA

Chen, M. Y., Gu, M. Y., Chu, S. R., Li, C., Fu, X. F., Zhang, K., Zeng, J. Z., & Liu, Y. C. (2026). Correlation Between Functional Scores and Objective Gait Parameters Following Rotating Hinge Knee Megaprosthesis Reconstruction. Orthopaedic Surgery, 18(5), 1042-1053. https://doi.org/10.1111/os.70300

Vancouver

Chen MY, Gu MY, Chu SR, Li C, Fu XF, Zhang K, et al. Correlation Between Functional Scores and Objective Gait Parameters Following Rotating Hinge Knee Megaprosthesis Reconstruction. Orthopaedic Surgery. 2026;18(5):1042-1053. doi:10.1111/os.70300

BibTeX
@article{Chen2026,
  author = {Chen, Meng-Yu and Gu, Ming-Yong and Chu, Sheng-Rui and Li, Chong and Fu, Xue-Fei and Zhang, Kuan and Zeng, Ji-Zhou and Liu, Yan-Cheng},
  title = {Correlation Between Functional Scores and Objective Gait Parameters Following Rotating Hinge Knee Megaprosthesis Reconstruction},
  journal = {Orthopaedic Surgery},
  year = {2026},
  volume = {18},
  number = {5},
  pages = {1042--1053},
  doi = {10.1111/os.70300}
}
Kostenlos starten →