Clinical Outcomes of RA FE ‐ TLIF Compared to FE ‐ TLIF in Patients With Lumbar Spondylolisthesis: A Retrospective Study
Orthopaedic Surgery · 2025-11 · 17 (11) · 3201-3210
DOI: 10.1111/os.70166 ↗Kurz gefasst
Vergleichsstudie in der Zeitschrift Orthopaedic Surgery, online erschienen am 04.09.2025. Verfasst von Lin Zhao und 7 weiteren Autor:innen. Beteiligte Einrichtung: Orthopedics Department, Gansu Provincial People's Hospital, Lanzhou, China. Hauptthemen laut MEDLINE: Spondylolisthesis, Spinal Fusion, Lumbar Vertebrae, Robotic Surgical Procedures. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 43 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0). Gefördert von: Special Project of Key Laboratory of National Health Commission, Natural Science Foundation in Gansu.
Abstract (Originalsprache)
Background
Lumbar spondylolisthesis (LS) is a spinal disorder that often necessitates surgical intervention. However, evidence on the comparative clinical value of robot‐assisted full‐endoscopic transforaminal lumbar interbody fusion (RA FE‐TLIF) versus conventional FE‐TLIF in early‐grade (Grades I and II) LS remains limited, leaving uncertainty about its true clinical value in this patient population. This study aims to compare the clinical efficacy and safety of FE‐TLIF with RA FE‐TLIF in patients with Grade I and II LS.
Methods
A retrospective analysis was conducted on 47 patients who underwent surgical treatment for LS between April 2022 and April 2023 at our hospital. Patients were divided into two groups: 22 underwent RA FE‐TLIF, and 25 underwent FE‐TLIF. Key outcomes measured included operative time, intraoperative blood loss, postoperative recovery time, fusion rate, screw placement accuracy, Visual Analogue Scale (VAS), the Japanese Orthopaedic Association (JOA) scores, and the incidence of postoperative complications. Statistical analyses were performed using the independent‐sample t test for continuous variables and the chi‐square test for categorical variables, with a significance threshold of p < 0.05.
Results
The RA FE‐TLIF group exhibited significantly shorter operative times and lower intraoperative blood loss compared to the FE‐TLIF group ( p < 0.05). Postoperative recovery, as measured by hospital stay, was also shorter in the RA FE‐TLIF group ( p = 0.001). VAS and JOA scores indicated greater pain relief and functional improvement in the RA FE‐TLIF group, with statistically significant differences observed at both 1 month and final follow‐up ( p < 0.05). The incidence of postoperative complications was lower in the RA FE‐TLIF group, though this difference was not statistically significant ( p = 0.144). Complete fusion rates were 95.45% in the RA FE‐TLIF group and 88.00% in the FE‐TLIF group, with no significant difference ( p > 0.05). Screw placement accuracy was higher in the RA FE‐TLIF group (97.73%) than in the FE‐TLIF group (89.00%), with a significant difference ( p < 0.05).
Conclusion
RA FE‐TLIF demonstrates superior clinical outcomes compared to FE‐TLIF in the treatment of LS. These findings support the broader adoption of RA FE‐TLIF as a preferred surgical technique for this condition.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Orthopedics Department, Gansu Provincial People's Hospital, Lanzhou, China.
- Radiology Department, Gansu Provincial People's Hospital, Lanzhou, China.
- Department of Pediatric Neurology, Gansu Maternal and Child Health Hospital, Lanzhou, Gansu, China.
ORCID-Profile: Jie Liu
Förderung
- Special Project of Key Laboratory of National Health Commission
- Natural Science Foundation in Gansu
Zitieren
APA
Zhao, L., Peng, Z., Cao, L., Lu, M., Wu, Z., Ding, N., Zhou, S., & Liu, J. (2025). Clinical Outcomes of RA FE ‐ TLIF Compared to FE ‐ TLIF in Patients With Lumbar Spondylolisthesis: A Retrospective Study. Orthopaedic Surgery, 17(11), 3201-3210. https://doi.org/10.1111/os.70166
Vancouver
Zhao L, Peng Z, Cao L, Lu M, Wu Z, Ding N, et al. Clinical Outcomes of RA FE ‐ TLIF Compared to FE ‐ TLIF in Patients With Lumbar Spondylolisthesis: A Retrospective Study. Orthopaedic Surgery. 2025;17(11):3201-3210. doi:10.1111/os.70166
BibTeX
@article{Zhao2025,
author = {Zhao, Lin and Peng, Zhengxuan and Cao, Lei and Lu, Mingdong and Wu, Zhanxiang and Ding, Ning and Zhou, Sheng and Liu, Jie},
title = {Clinical Outcomes of RA FE ‐ TLIF Compared to FE ‐ TLIF in Patients With Lumbar Spondylolisthesis: A Retrospective Study},
journal = {Orthopaedic Surgery},
year = {2025},
volume = {17},
number = {11},
pages = {3201--3210},
doi = {10.1111/os.70166}
}