Comparison of Suture Anchor Repair and Suture Tape Augmentation for Reconstruction of the Anterior Talofibular Ligament: A Biomechanical Study
Orthopaedic Surgery · 2025-01 · 17 (1) · 244-251
DOI: 10.1111/os.14284 ↗Kurz gefasst
Vergleichsstudie in der Zeitschrift Orthopaedic Surgery, online erschienen am 10.11.2024. Verfasst von Qingfeng Shao und 8 weiteren Autor:innen. Beteiligte Einrichtung: Department of Sports Medicine, The First Affiliated Hospital, Guangdong Provincial Key Laboratory of Speed Capability, The Guangzhou Key Laboratory o…. Hauptthemen laut MEDLINE: Suture Anchors, Lateral Ligament, Ankle, Surgical Tape, Ankle Injuries. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 34 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0). Gefördert von: Medical Joint Fund of Jinan University, Science and Technology Innovation and Sports Culture Development Research Project of Guangdong Provincial Sports Bureau, Fundamental Research Funds for the Central Universities.
Abstract (Originalsprache)
Objectives
Currently, there are various surgical options for the treatment of lateral ankle sprains, and deciding which surgical option to use is a question worth considering. Furthermore, there is a relative scarcity of mechanical research comparing suture anchor repair (SAR) and suture tape augmentation (STA) internal brace for the repair of the anterior talofibular ligament (ATFL). Therefore, this study aimed to compare the efficacy of arthroscopically all‐inside ATFL SAR and STA for reconstruction to treat lateral ankle sprains through biomechanical testing.
Methods
Eighteen fresh‐frozen cadaver ankles were used for the study and divided into one of three groups: (1) intact ATFL group, (2) arthroscopically reconstructed with suture tape augmentation internal brace of the ATFL (STA group), and (3) arthroscopically repaired ATFL with suture anchors (SAR group). We used custom fixtures to test the specimens for loading to ultimate failure and stiffness.
Results
The mean load to failure of the STA group (311.20 ± 52.56 N) was significantly higher than that of the intact ATFL group (157.37 ± 63.87 N; p = 0.0016) and the SAR group (165.27 ± 66.81 N; p = 0.0025). The mean stiffness of the STA group (30.10 ± 5.10 N/mm) was significantly higher than that of the intact ATFL (14.17 ± 6.35 N/mm; p = 0.0012) and the SAR group (15.15 ± 6.89 N/mm; p = 0.0021). The suture anchor repair withstood failure loads and stiffness similar to the intact ATFL.
Conclusions
In terms of failure load and stiffness, the reconstructive outcome of ATFL reconstruction with STA is markedly superior to that of SAR reconstruction of the ATFL and the intact ATFL. Additionally, the novel technique of the SAR was a reliable technique that offered biomechanical properties similar to intact ATFL.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Sports Medicine, The First Affiliated Hospital, Guangdong Provincial Key Laboratory of Speed Capability, The Guangzhou Key Laboratory of Precision Orthopedics and Regenerative Medicine, Jinan University, G…
- Department of Joint Surgery and Sports Medicine, The First People's Hospital of Zhaoqing, Zhaoqing, China.
- The Biomedical Translational Research Institute, Jinan University, Guangzhou, China.
Förderung
- Medical Joint Fund of Jinan University
- Science and Technology Innovation and Sports Culture Development Research Project of Guangdong Provincial Sports Bureau
- Fundamental Research Funds for the Central Universities
- Science and Technology Projects in Guangzhou
- Project of China University Sports Association
- Project of Clinical Medical Research in the First Affiliated Hospital of Jinan University
- Medical Scientific Research Foundation of Guangdong Province
- The Research Fund Program of Guangdong Provincial Key Laboratory of Speed Capability Research
Zitieren
APA
Shao, Q., Hu, D., Chen, X., Wang, H., Xiao, L., Teng, Q., Hong, J., Hou, H., & Zheng, X. (2025). Comparison of Suture Anchor Repair and Suture Tape Augmentation for Reconstruction of the Anterior Talofibular Ligament: A Biomechanical Study. Orthopaedic Surgery, 17(1), 244-251. https://doi.org/10.1111/os.14284
Vancouver
Shao Q, Hu D, Chen X, Wang H, Xiao L, Teng Q, et al. Comparison of Suture Anchor Repair and Suture Tape Augmentation for Reconstruction of the Anterior Talofibular Ligament: A Biomechanical Study. Orthopaedic Surgery. 2025;17(1):244-251. doi:10.1111/os.14284
BibTeX
@article{Shao2025,
author = {Shao, Qingfeng and Hu, Dahai and Chen, Xinru and Wang, Huajun and Xiao, Lei and Teng, Qiang and Hong, Jinsong and Hou, Huige and Zheng, Xiaofei},
title = {Comparison of Suture Anchor Repair and Suture Tape Augmentation for Reconstruction of the Anterior Talofibular Ligament: A Biomechanical Study},
journal = {Orthopaedic Surgery},
year = {2025},
volume = {17},
number = {1},
pages = {244--251},
doi = {10.1111/os.14284}
}
EUVIMED