A More Efficient and Safer Improved Percutaneous Pedicle Screw Insertion Technique—Trajectory Dynamic Adjustment Technique, Technical Note, and Clinical Efficacy
Orthopaedic Surgery · 2025
DOI: 10.1111/os.14260 ↗Kurz gefasst
Fachartikel in der Zeitschrift Orthopaedic Surgery, 2025. Verfasst von Hao Li und 8 weiteren Autor:innen. Beteiligte Einrichtung: Department of Orthopedics, Beijing Jishuitan Hospital, Capital Medical University, Beijing, China. Hauptthemen laut MEDLINE: Pedicle Screws, Lumbar Vertebrae, Spinal Fusion, Spondylolisthesis. Die Arbeit nennt 35 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Natural Science Foundation of Shandong Province.
Abstract (Originalsprache)
Objective
Percutaneous pedicle screw fixation (PPSF) technique requires a very precise entry point of the Jamshidi needle, which leads to repeated adjustments, damaging the pedicle and increasing radiation exposure. This study was designed to propose an improved percutaneous pedicle screw fixation technique‐trajectory dynamic adjustment (TDA) technique, and evaluate its feasibility and assess the clinical outcomes.
Method
A total of 445 patients with lumbar spondylolisthesis or lumbar spinal stenosis associated with instability from June 2017 to May 2022 were included in the retrospective study. They were randomly separated into two groups. Two hundred thirty‐one patients underwent TDA technique (TDA group). Two hundred fourteen patients underwent traditional PPSF technique (PPSF group). All patients underwent postoperative CT to assess the accuracy of screw placement, superior facet joint violation (FJV). The evaluated clinical outcomes were needle insertion time, radiation exposure, blood loss, hospital stay, the Japanese Orthopedic Association (JOA) score, the Visual Analogue Scale (VAS) scores for lower back pain (LBP), and leg pain, lumbar interbody fusion rate, and postoperative complications. The independent‐sample t test and paired t‐test were used for continuous data. The contingency table and Mann–Whitney U test were used for categorical data.
Results
The time of the insertion in TDA group was significantly lower than that in PPSF group ( p < 0.05). Similarly, the fluoroscopy frequency in TDA group was significantly lower than that in PPSF group ( p < 0.05). There was no difference in intraoperative blood loss and hospital stay between the two groups ( p > 0.05). Overall, there was no significant difference in the proportion of clinically acceptable screws between the two groups ( p > 0.05). In addition, the lateral screw misplacement in TDA group was higher. Moreover, FJV rate was significantly lower than that in PPSF group ( p < 0.05). In both TDA group and PPSF group, postoperative back and leg pain and the JOA score were significantly improved ( p < 0.05). However, there were no significant differences in the pre‐ and postoperative VAS score for back and leg pain and the JOA score, JOA recovery rate, intervertebral fusion rate, and complications rate between the two groups ( p > 0.05).
Conclusion
Compared to traditional PPSF technique, TDA technique is a safer and more effective procedure which has shorter surgical time, lower radiation exposure, and lower facet joint violation rate.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Orthopedics, Beijing Jishuitan Hospital, Capital Medical University, Beijing, China.
- Department of Orthopedics, Qilu Hospital of Shandong University, Jinan, Shandong, People's Republic of China.
- Department of Orthopedics, Shouguang People's Hospital, Weifang, Shandong, People's Republic of China.
- Shandong Provincial Maternal and Child Health Care Hospital Affiliated to Qingdao University, Jinan, China.
- Department of Dermatology, The Second Affiliated Hospital of Xi'an Jiaotong University, Xi'an, Shanxi, People's Republic of China.
Förderung
- Natural Science Foundation of Shandong Province
Zitieren
APA
Li, H., Ding, Z., Wei, B., Ma, Z., Xie, J., Tian, Y., Wang, L., Liu, X., & Yuan, S. (2025). A More Efficient and Safer Improved Percutaneous Pedicle Screw Insertion Technique—Trajectory Dynamic Adjustment Technique, Technical Note, and Clinical Efficacy. Orthopaedic Surgery. https://doi.org/10.1111/os.14260
Vancouver
Li H, Ding Z, Wei B, Ma Z, Xie J, Tian Y, et al. A More Efficient and Safer Improved Percutaneous Pedicle Screw Insertion Technique—Trajectory Dynamic Adjustment Technique, Technical Note, and Clinical Efficacy. Orthopaedic Surgery. 2025. doi:10.1111/os.14260
BibTeX
@article{Li2025,
author = {Li, Hao and Ding, Zhiguo and Wei, Bin and Ma, Zhihao and Xie, Jing and Tian, Yonghao and Wang, Lianlei and Liu, Xinyu and Yuan, Suomao},
title = {A More Efficient and Safer Improved Percutaneous Pedicle Screw Insertion Technique—Trajectory Dynamic Adjustment Technique, Technical Note, and Clinical Efficacy},
journal = {Orthopaedic Surgery},
year = {2025},
doi = {10.1111/os.14260}
}
EUVIMED