EUVIMEDEUVIMED entdecken
VergleichsstudieOpen Access · CC BY-NC 4.0

Bone Transport for Large Segmental Tibial Defects Using Taylor Spatial Frame versus the Ilizarov Circular Fixator

Bowen Shi, Zhongli Zhang, Guoqi Ji, Chengkuo Cai, Hengsheng Shu, Xinlong Ma iD

Orthopaedic Surgery · 2024

DOI: 10.1111/os.14192 ↗

Kurz gefasst

Vergleichsstudie in der Zeitschrift Orthopaedic Surgery, 2024. Verfasst von Bowen Shi und 5 weiteren Autor:innen. Beteiligte Einrichtung: Clinical School of Orthopedics, Tianjin Medical University, Tianjin, China. Hauptthemen laut MEDLINE: Ilizarov Technique, External Fixators. Die Arbeit wurde bisher 15-mal zitiert (Crossref) und nennt 24 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0). Gefördert von: National Key Research and Development Program of China.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objective

Bone transport has become the gold standard for treating large segmental tibial bone defects. The technique for application the Ilizarov circular fixator (ICF) has a long learning curve and is associated with many complications. There are few clinical studies on bone transport via the Taylor spatial frame (TSF). The main purpose of this study was to compare the radiological and clinical and outcomes of bone transport by using the TSF and the ICF.

Methods

There were 62 patients included in this retrospective study from June 2011 to June 2021 and distributed to two groups according to the fixation method: a TSF group consisting of 30 patients and an ICF group consisting of 32 patients. Demographic information, surgical duration, external fixation times, external fixation index, final radiographic results, complications, and clinical outcomes were recorded and examined. The clinical outcomes were assessed using the ASAMI criteria during the most recent clinical visit. Then, statistical analysis such as independent‐samples t tests or chi‐Square test was performed.

Results

The mean surgical duration in the TSF group was 93.8 ± 7.3 min, which was shorter than that in the ICF group (109.8 ± 1.4 min) ( p < 0.05). Compared to the ICF group (10.2 ± 2.0 months), the TSF group (9.7 ± 1.8 months) had a shorter average external fixation time ( p > 0.05). The external fixation index was 1.4 ± 0.2 m/cm and 1.5 ± 0.1 m/cm in the two groups. Moreover, there was no significant difference between the two groups. At the last follow‐up visit, the medial proximal tibial angle (MPTA) and posterior proximal tibial angle (PPTA) in the TSF group were 88.1 ± 12.1° and 80.9 ± 1.3°, respectively. The MPTA and PPTA in the ICF group were 84.4 ± 2.4° and 76.2 ± 1.9°, respectively. There were statistically significant differences between the two groups (all p < 0.05). The complication rate was 50% in the TSF group and 75% in the ICF group. Moreover, the ASAMI score between the two groups was no statistically significant difference ( p > 0.05).

Conclusion

No statistically significant difference was found in clinical outcomes between the use of Taylor spatial frame and Ilizarov circular fixator for treating large segmental tibial bone defects. However, TSF is a shorter and simpler procedure that causes fewer complications and improves limb alignment.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Ilizarov TechniqueExternal FixatorsHumansRetrospective StudiesMaleFemaleAdultMiddle AgedTibial FracturesTibiaAged

Stichwörter der Autor:innen

Bone defectsBone transportExternal fixatorsIlizarov techniqueTibial fractures

Autor:innen und Institutionen

  • Clinical School of Orthopedics, Tianjin Medical University, Tianjin, China.
  • Department of Orthopedic Traumatology, Tianjin Hospital, Tianjin, China.
  • Department of Pediatric Orthopedics, Tianjin Hospital, Tianjin, China.

ORCID-Profile: Xinlong Ma

Förderung

  • National Key Research and Development Program of China

Zitieren

APA

Shi, B., Zhang, Z., Ji, G., Cai, C., Shu, H., & Ma, X. (2024). Bone Transport for Large Segmental Tibial Defects Using Taylor Spatial Frame versus the Ilizarov Circular Fixator. Orthopaedic Surgery. https://doi.org/10.1111/os.14192

Vancouver

Shi B, Zhang Z, Ji G, Cai C, Shu H, Ma X. Bone Transport for Large Segmental Tibial Defects Using Taylor Spatial Frame versus the Ilizarov Circular Fixator. Orthopaedic Surgery. 2024. doi:10.1111/os.14192

BibTeX
@article{Shi2024,
  author = {Shi, Bowen and Zhang, Zhongli and Ji, Guoqi and Cai, Chengkuo and Shu, Hengsheng and Ma, Xinlong},
  title = {Bone Transport for Large Segmental Tibial Defects Using Taylor Spatial Frame versus the Ilizarov Circular Fixator},
  journal = {Orthopaedic Surgery},
  year = {2024},
  doi = {10.1111/os.14192}
}
Kostenlos starten →