EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC 4.0

Changes in Patellar Height and Tibial Posterior Slope after Biplanar High Tibial Osteotomy with Computer‐Designed Personalized Surgical Guides: A Retrospective Study

Chang Liu, Wei Luo, Jianxiong Ma, Songqing Ye, Bin Zhao, Haohao Bai, Fei Xing, Xuan Jiang, Xinlong Ma iD

Orthopaedic Surgery · 2024

DOI: 10.1111/os.14049 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Orthopaedic Surgery, 2024. Verfasst von Chang Liu und 8 weiteren Autor:innen. Beteiligte Einrichtung: Tianjin Hospital, Tianjin, China. Hauptthemen laut MEDLINE: Osteotomy, Tibia, Patella, Osteoarthritis, Knee. Die Arbeit wurde bisher 7-mal zitiert (Crossref) und nennt 51 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0). Gefördert von: Tianjin Municipal Health Science and Technology Project, top-level project: research on personalized knee preservation for knee osteoarthritis based on osteoto…, Central Guided Local Science and Technology Development Funds, Science and Technology Innovation Base Project, Research on Key Technology and Clinical Applicat….

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objective

Medial opening‐wedge high tibial osteotomy (MOWHTO) is a surgical procedure to treat medial compartment osteoarthritis in the knee with varus deformity. However, factors such as patellar height (PH) and the sagittal plane's posterior tibial slope angle (PTSA) are potentially overlooked. This study investigated the impact of alignment correction angle guided by computer‐designed personalized surgical guide plate (PSGP) in MOWHTO on PH and PTSA, offering insights for enhancing surgical techniques.

Methods

This retrospective study included patients who underwent 3D‐printed PSGP‐assisted MOWHTO at our institution from March to September 2022. The paired t‐tests assessed differences in all preoperative and postoperative measurement parameters. Multivariate linear regression analysis examined correlations between PTSA, CDI (Caton–Deschamps Index), and the alignment correction magnitude. Receiver operating characteristic (ROC) curve analysis determined the threshold of the correction angle, calculating sensitivity, specificity, and area under the curve.

Results

A total of 107 patients were included in our study. The CDI changed from a preoperative mean of 0.97 ± 0.13 (range 0.70–1.34) to a postoperative mean of 0.82 ± 0.13 (range 0.55–1.20). PTSA changed from a preoperative mean of 8.54 ± 2.67 (range 2.19–17.55) to a postoperative mean of 10.54 ± 3.05 (range 4.48–18.05). The t ‐test revealed statistically significant changes in both values ( p < 0.05). A significant alteration in patellar height occurred when the correction angle exceeded 9.39°. Moreover, this paper illustrates a negative correlation between CDI change and the correction angle and preoperative PTSA. Holding other factors constant, each 1‐degree increase in the correction angle led to a 0.017 decrease in postoperative CDI, and each 1‐degree increase in preoperative PTSA resulted in a 0.008 decrease in postoperative CDI. PTSA change was positively correlated only with the correction angle; for each 1‐degree increase in the opening angle, postoperative PTS increased by 0.188, with other factors constant.

Conclusion

This study highlights the effectiveness and precision of PSGP‐assisted MOWHTO, focusing on the impact of alignment correction on PH and PTSA. These findings support the optimization of PSGP technology, which offers simpler, faster, and safer surgeries with less radiation and bleeding than traditional methods. However, PSGP's one‐time use design and the learning curve required for its application are limitations, suggesting areas for further research.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

OsteotomyTibiaPatellaOsteoarthritis, KneeSurgery, Computer-AssistedHumansRetrospective StudiesFemaleMaleMiddle AgedAdultAgedPrinting, Three-Dimensional

Stichwörter der Autor:innen

Knee osteoarthritisMedial opening‐wedge high tibial osteotomyPatellar heightPersonalized surgical guide platePosterior tibial slope angle

Autor:innen und Institutionen

  • Tianjin Hospital, Tianjin, China.

ORCID-Profile: Xinlong Ma

Förderung

  • Tianjin Municipal Health Science and Technology Project, top-level project: research on personalized knee preservation for knee osteoarthritis based on osteoto…
  • Central Guided Local Science and Technology Development Funds, Science and Technology Innovation Base Project, Research on Key Technology and Clinical Applicat…

Zitieren

APA

Liu, C., Luo, W., Ma, J., Ye, S., Zhao, B., Bai, H., Xing, F., Jiang, X., & Ma, X. (2024). Changes in Patellar Height and Tibial Posterior Slope after Biplanar High Tibial Osteotomy with Computer‐Designed Personalized Surgical Guides: A Retrospective Study. Orthopaedic Surgery. https://doi.org/10.1111/os.14049

Vancouver

Liu C, Luo W, Ma J, Ye S, Zhao B, Bai H, et al. Changes in Patellar Height and Tibial Posterior Slope after Biplanar High Tibial Osteotomy with Computer‐Designed Personalized Surgical Guides: A Retrospective Study. Orthopaedic Surgery. 2024. doi:10.1111/os.14049

BibTeX
@article{Liu2024,
  author = {Liu, Chang and Luo, Wei and Ma, Jianxiong and Ye, Songqing and Zhao, Bin and Bai, Haohao and Xing, Fei and Jiang, Xuan and Ma, Xinlong},
  title = {Changes in Patellar Height and Tibial Posterior Slope after Biplanar High Tibial Osteotomy with Computer‐Designed Personalized Surgical Guides: A Retrospective Study},
  journal = {Orthopaedic Surgery},
  year = {2024},
  doi = {10.1111/os.14049}
}
Kostenlos starten →