Arthroscopic Linear Chain Fixation for the Treatment of Medial Meniscus Posterior Root Tear: A Case Study

Jing-Qing Chen iD, Hai-Yun Niu, Ming Li, Zhen-Yue Dong, Ju-Yuan Gu, Wei-Xia Bai, Bai-Cheng Chen

Orthopaedic Surgery · 2024

DOI: 10.1111/os.13975 ↗

Kurz gefasst

Fallbericht in der Zeitschrift Orthopaedic Surgery, 2024. Verfasst von Jing-Qing Chen und 6 weiteren Autor:innen. Beteiligte Einrichtung: Orthopedics Department of Joint Surgury, the Third Hospital of Hebei Medical University, Shijiazhuang, China. Hauptthemen laut MEDLINE: Menisci, Tibial, Tibial Meniscus Injuries. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 22 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Hebei Province key research and development plan project.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

The repair and reconstruction of medial meniscus posterior root tears (MMPRTs) is an important issue in the field of orthopedic sports medicine. This study reports the first application of arthroscopic linear chain fixation for the treatment of MMPRTs. Case presentation A 78‐year‐old female patient presented with a 1.5‐month history of right knee pain accompanied by a locked facet joint. The patient underwent surgery with the new linear chain fixation method. In this method, the suture and the loop part of the buckle‐strap titanium plate were combined into a linear chain mechanical complex, and the tension of the posterior root stump was gradually increased by pulling on the two attachment lines at the external mouth of the tibial tunnel. The postoperative Lysholm score was 89, and the visual analogue scale score was 0.9, indicating a significant improvement in knee joint function. At the 7‐month and 1‐year post‐surgery follow‐up, physical and MRI examinations confirmed satisfactory healing of the MMPRTs.

Conclusion

This surgical approach offers several benefits, including a simplified instrumentation setup, preservation of natural anatomical structures, and reliable residual stump fixation. It has the potential for clinical implementation.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Menisci, TibialTibial Meniscus InjuriesFemaleHumansAgedArthroscopyKnee JointTibiaRupture

Stichwörter der Autor:innen

ArthroscopyMedial meniscusMeniscus posterior root tearRepair surgery

Autor:innen und Institutionen

  • Orthopedics Department of Joint Surgury, the Third Hospital of Hebei Medical University, Shijiazhuang, China.

ORCID-Profile: Jing-Qing Chen

Förderung

  • Hebei Province key research and development plan project

Zitieren

APA

Chen, J. Q., Niu, H. Y., Li, M., Dong, Z. Y., Gu, J. Y., Bai, W. X., & Chen, B. C. (2024). Arthroscopic Linear Chain Fixation for the Treatment of Medial Meniscus Posterior Root Tear: A Case Study. Orthopaedic Surgery. https://doi.org/10.1111/os.13975

Vancouver

Chen JQ, Niu HY, Li M, Dong ZY, Gu JY, Bai WX, et al. Arthroscopic Linear Chain Fixation for the Treatment of Medial Meniscus Posterior Root Tear: A Case Study. Orthopaedic Surgery. 2024. doi:10.1111/os.13975

BibTeX
@article{Chen2024,
  author = {Chen, Jing-Qing and Niu, Hai-Yun and Li, Ming and Dong, Zhen-Yue and Gu, Ju-Yuan and Bai, Wei-Xia and Chen, Bai-Cheng},
  title = {Arthroscopic Linear Chain Fixation for the Treatment of Medial Meniscus Posterior Root Tear: A Case Study},
  journal = {Orthopaedic Surgery},
  year = {2024},
  doi = {10.1111/os.13975}
}
Kostenlos starten →