EUVIMEDEUVIMED entdecken
Randomisierte kontrollierte StudieVergleichsstudie

Comparative evaluation of different (peripheral defocus based) spectacle designs in preventing myopia progression: A double‐blinded randomised clinical trial

Vinay Gupta iD, Rohit Saxena iD, Rebika Dhiman, Swati Phuljhele, Namrata Sharma iD

Ophthalmic and Physiological Optics · 2025-09 · 45 (6) · 1505-1511

DOI: 10.1111/opo.13548 ↗

Kurz gefasst

Randomisierte kontrollierte Studie in der Zeitschrift Ophthalmic and Physiological Optics, online erschienen am 24.06.2025. Verfasst von Vinay Gupta und 4 weiteren Autor:innen. Beteiligte Einrichtung: Dr. R. P. Centre for Ophthalmic Sciences, AIIMS, New Delhi, India. Hauptthemen laut MEDLINE: Eyeglasses, Refraction, Ocular, Myopia, Visual Acuity. Die Arbeit wurde bisher 17-mal zitiert (Crossref) und nennt 27 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

This study aimed to evaluate and compare the efficacy of different peripheral defocus‐based spectacle designs [Defocus Induced Multiple Segment (DIMS), Highly Aspherical Lenslets (HALT) and Cylindrical Annular Refractive Elements (CARE)] in controlling myopia progression.

Methods

This was a prospective, interventional, double‐blinded, randomised clinical trial. Children aged 5 to 15 years, with myopia ranging from −1 D to −8 D and documented myopia progression of ≥0.5 D/year, were randomly assigned (1:1:1) to wear either DIMS, HALT or CARE spectacles full‐time. Cycloplegic refraction and axial length measurements were taken at baseline and after 1 year. The primary outcome was the change in the rate of myopia progression. All analyses were performed based on the intention‐to‐treat principle.

Results

A total of 120 participants (40 in each group: DIMS, HALT and CARE) with a mean age of 10.1 ± 3.3 years (57% male) were enrolled. At the 1‐year follow‐up, the rate of myopia progression reduced by 0.38 ± 0.13 D/year (56.7%), 0.36 ± 0.12 D/year (58.1%) and 0.31 ± 0.15 D/year (47%) for the DIMS, HALT and CARE groups, respectively. The respective change in axial length was 0.2 ± 0.11 mm, 0.19 ± 0.12 mm and 0.23 ± 0.14 mm. Inter‐group comparisons showed a significant difference in spherical equivalent refractive error changes between HALT and CARE ( p = 0.04) and in the rate of myopia progression between DIMS and CARE ( p = 0.04). No significant differences were found between HALT and DIMS for any parameter.

Conclusions

Spectacle lenses incorporating peripheral defocus (DIMS, HALT and CARE) were all effective in reducing the rate of myopia progression significantly, with no adverse effects being observed. Among the three designs, DIMS and HALT exhibited comparable and significantly better efficacy than CARE spectacles at 1 year follow‐up. However, further long‐term studies are required to validate these findings.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

EyeglassesRefraction, OcularMyopiaVisual AcuityMyopia, DegenerativeHumansMaleDouble-Blind MethodChildFemaleAdolescentDisease ProgressionProspective StudiesChild, PreschoolEquipment DesignFollow-Up Studies

Stichwörter der Autor:innen

CAREDIMSHALTmyopia controlmyopia spectaclesperipheral defocus

Autor:innen und Institutionen

  • Dr. R. P. Centre for Ophthalmic Sciences, AIIMS, New Delhi, India.

ORCID-Profile: Vinay Gupta, Rohit Saxena, Namrata Sharma

Zitieren

APA

Gupta, V., Saxena, R., Dhiman, R., Phuljhele, S., & Sharma, N. (2025). Comparative evaluation of different (peripheral defocus based) spectacle designs in preventing myopia progression: A double‐blinded randomised clinical trial. Ophthalmic and Physiological Optics, 45(6), 1505-1511. https://doi.org/10.1111/opo.13548

Vancouver

Gupta V, Saxena R, Dhiman R, Phuljhele S, Sharma N. Comparative evaluation of different (peripheral defocus based) spectacle designs in preventing myopia progression: A double‐blinded randomised clinical trial. Ophthalmic and Physiological Optics. 2025;45(6):1505-1511. doi:10.1111/opo.13548

BibTeX
@article{Gupta2025,
  author = {Gupta, Vinay and Saxena, Rohit and Dhiman, Rebika and Phuljhele, Swati and Sharma, Namrata},
  title = {Comparative evaluation of different (peripheral defocus based) spectacle designs in preventing myopia progression: A double‐blinded randomised clinical trial},
  journal = {Ophthalmic and Physiological Optics},
  year = {2025},
  volume = {45},
  number = {6},
  pages = {1505--1511},
  doi = {10.1111/opo.13548}
}
Kostenlos starten →