Optimising non‐cycloplegic screening strategies for early detection of pre‐myopia and myopia in young children
Ophthalmic and Physiological Optics · 2025
DOI: 10.1111/opo.13525 ↗Kurz gefasst
Fachartikel in der Zeitschrift Ophthalmic and Physiological Optics, 2025. Verfasst von Síofra Harrington und 4 weiteren Autor:innen. Beteiligte Einrichtung: School of Physics, Clinical & Optometric Sciences, Technological University Dublin, Dublin, Ireland. Hauptthemen laut MEDLINE: Myopia, Refraction, Ocular, Vision Screening, Visual Acuity. Die Arbeit wurde bisher 10-mal zitiert (Crossref) und nennt 55 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: TU Dublin Fiosraigh Award, Optometry Ireland.
Themen: Kinderkrankenpflege
Abstract (Originalsprache)
Purpose
Early detection of myopia is essential to delay its onset and progression. Pre‐myopia, defined by an inadequate hyperopic reserve, increases myopia risk in childhood. However, effective screening methods remain limited. This study aimed to develop practical non‐cycloplegic screening methods for pre‐myopia and myopia in 6‐ to 7‐year‐olds to support earlier interventions.
Methods
This cross‐sectional study of 621 Irish schoolchildren (mean age: 7.12 ± 0.45 years; 51.8% boys) assessed uncorrected distance visual acuity (UDVA). Cycloplegic spherical equivalent refraction (SER) classified refractive status (myopia: SER ≤ −0.50D; pre‐myopia: SER > −0.50 ≤ 0.75D). Pre‐ and post‐cycloplegic SER were measured using the Welch Allyn Spot Vision Screener and Dong‐Yang Rekto‐ORK 11, respectively. Axial length (AL) and corneal radius (CR) were measured with the Zeiss IOLMaster and parental myopia history via questionnaire. Logistic regression and ROC curves evaluated non‐cycloplegic screening methods.
Results
Pre‐myopia prevalence was 24.3% (95% confidence intervals (CI): 29.3–36.2), and myopia prevalence was 3.3% (CI: 2.5–5.5). UDVA screening had an area under the curve (AUC) (CI) = 0.72 (0.59–0.86) and 0.42 (0.36–0.47) for detecting myopia and pre‐myopia, respectively. For pre‐myopia discrimination, non‐cycloplegic SER, AL, AL/CR and parental myopia had AUCs of 0.67 (0.62–0.72), 0.67 (0.62–0.72), 0.69 (0.64–0.74) and 0.59 (0.53–0.64), respectively. The best method combined non‐cycloplegic SER and AL/CR (AUC = 0.72 (0.67–0.76)). Including UDVA or parental myopia did not improve results. For myopia detection, AUCs were non‐cycloplegic SER:0.84 (0.72–0.97), AL:0.88 (0.82–0.95), AL/CR:0.84 (0.75–0.94) and parental myopia:0.62 (0.48–0.75). The best method combined AL and non‐cycloplegic SER 0.94 (0.90–0.99). Adding parental myopia did not improve the AUC = 0.93 (0.87–0.99) but adding UDVA achieved an AUC = 0.95 (0.90–0.99).
Conclusion
While UDVA alone provided acceptable discrimination for myopia, it was insufficient for screening pre‐myopia. Non‐cycloplegic SER alone had relatively poor discrimination for pre‐myopia, but its performance improved when combined with the AL/CR ratio. The best results for myopia discrimination were achieved by combining non‐cycloplegic SER, axial length and UDVA measures.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- School of Physics, Clinical & Optometric Sciences, Technological University Dublin, Dublin, Ireland.
- Centre for Eye Research Ireland, Sustainability & Health Research Centre, Technological University Dublin, City Campus, Dublin, Ireland.
- Department of Ophthalmology, Mater Misericordiae Hospital, Dublin, Ireland.
ORCID-Profile: Síofra Harrington, Michael Moore, James Loughman
Förderung
- TU Dublin Fiosraigh Award
- Optometry Ireland
Zitieren
APA
Harrington, S., Moore, M., Loughman, J., Flitcroft, I., & O'Dwyer, V. (2025). Optimising non‐cycloplegic screening strategies for early detection of pre‐myopia and myopia in young children. Ophthalmic and Physiological Optics. https://doi.org/10.1111/opo.13525
Vancouver
Harrington S, Moore M, Loughman J, Flitcroft I, O'Dwyer V. Optimising non‐cycloplegic screening strategies for early detection of pre‐myopia and myopia in young children. Ophthalmic and Physiological Optics. 2025. doi:10.1111/opo.13525
BibTeX
@article{Harrington2025,
author = {Harrington, Síofra and Moore, Michael and Loughman, James and Flitcroft, Ian and O'Dwyer, Veronica},
title = {Optimising non‐cycloplegic screening strategies for early detection of pre‐myopia and myopia in young children},
journal = {Ophthalmic and Physiological Optics},
year = {2025},
doi = {10.1111/opo.13525}
}
EUVIMED