EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC-ND 4.0

Subjective and objective measurements of the amplitude of accommodation: Revisiting the existing methods and clinical evaluation of newer techniques

Raquel Salvador-Roger iD, José J Esteve-Taboada iD, Abinaya Priya Venkataraman, Alberto Domínguez-Vicent

Ophthalmic and Physiological Optics · 2025

DOI: 10.1111/opo.13482 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Ophthalmic and Physiological Optics, 2025. Verfasst von Raquel Salvador-Roger und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Optics and Optometry and Vision Sciences, University of Valencia, Burjassot, Spain. Hauptthemen laut MEDLINE: Accommodation, Ocular, Presbyopia, Refraction, Ocular. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 37 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0). Gefördert von: Ministerio de Universidades.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

To evaluate the repeatability and agreement of established and newer methods for measuring the amplitude of accommodation in non‐presbyopic and early presbyopic individuals.

Methods

The amplitude of accommodation of 81 participants was measured using five different methods (two push‐up techniques, two minus lens techniques and one objective technique) with different measurement principles. Among these, two new techniques were introduced: an electronic push‐up and a minus lens technique with a tunable lens. Three repeated measurements were performed with each method. The repeatability limit and non‐parametric Bland–Altman analysis were used to describe the repeatability and agreement of each method.

Results

The repeatability limit was between ±0.7 D and ±1.4 D for the minus lens techniques, around ±1.8 D for the push‐up methods and ±1.4 D for the objective procedure. The largest differences in median values were found between the push‐up and objective methods.

Conclusions

Push‐up methods are most likely to overestimate accommodation, while the objective method gives the lowest results. New techniques show good repeatability for measuring the amplitude of accommodation. Among the subjective methods, the minus lens technique with the tunable lens gives the best repeatability, is one of the fastest and gives results most similar to the objective method.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Accommodation, OcularPresbyopiaRefraction, OcularHumansFemaleMaleReproducibility of ResultsMiddle AgedAdultAged

Stichwörter der Autor:innen

amplitude of accommodationautorefractometerminus lens methodpush‐up methodrepeatabilitytunable lens

Autor:innen und Institutionen

  • Department of Optics and Optometry and Vision Sciences, University of Valencia, Burjassot, Spain.
  • Unit of Optometry, Division of Eye and Vision, Department of Clinical Neuroscience, Karolinska Institute, Stockholm, Sweden.

ORCID-Profile: Raquel Salvador-Roger, José J Esteve-Taboada

Förderung

  • Ministerio de Universidades

Zitieren

APA

Salvador-Roger, R., Esteve-Taboada, J. J., Venkataraman, A. P., & Domínguez-Vicent, A. (2025). Subjective and objective measurements of the amplitude of accommodation: Revisiting the existing methods and clinical evaluation of newer techniques. Ophthalmic and Physiological Optics. https://doi.org/10.1111/opo.13482

Vancouver

Salvador-Roger R, Esteve-Taboada JJ, Venkataraman AP, Domínguez-Vicent A. Subjective and objective measurements of the amplitude of accommodation: Revisiting the existing methods and clinical evaluation of newer techniques. Ophthalmic and Physiological Optics. 2025. doi:10.1111/opo.13482

BibTeX
@article{SalvadorRoger2025,
  author = {Salvador-Roger, Raquel and Esteve-Taboada, José J and Venkataraman, Abinaya Priya and Domínguez-Vicent, Alberto},
  title = {Subjective and objective measurements of the amplitude of accommodation: Revisiting the existing methods and clinical evaluation of newer techniques},
  journal = {Ophthalmic and Physiological Optics},
  year = {2025},
  doi = {10.1111/opo.13482}
}
Kostenlos starten →