Impact of proxymetacaine on the dynamics of cyclopentolate in White 6‐ to 7‐year‐olds
Ophthalmic and Physiological Optics · 2025-01 · 45 (1) · 4-13
DOI: 10.1111/opo.13421 ↗Kurz gefasst
Fachartikel in der Zeitschrift Ophthalmic and Physiological Optics, online erschienen am 13.11.2024. Verfasst von Megan Doyle und 2 weiteren Autor:innen. Beteiligte Einrichtung: School of Physics, Clinical & Optometric Sciences, Centre for Eye Research Ireland, Sustainability & Health Research Centre, Technological University…. Hauptthemen laut MEDLINE: Cyclopentolate, Mydriatics, Propoxycaine, Refraction, Ocular. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 38 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0). Gefördert von: Optometry Ireland, Technological University Dublin Fiosraigh Scholarship.
Abstract (Originalsprache)
Purpose
This study compared the efficacy of cyclopentolate hydrochloride at 10‐, 20‐ and 30‐min post‐instillation in White 6‐ to 7‐year‐olds, with and without prior instillation of proxymetacaine hydrochloride. The primary aim was to determine if accurate autorefraction values can be obtained sooner than the current standard of 30‐min post‐cycloplegia. The secondary aim was to investigate whether proxymetacaine hydrochloride enhances the efficiency of cyclopentolate.
Methods
Participants were 112 White 6‐ to 7‐year‐olds from the Child Eye Health Study. The right eye received 0.5% proxymetacaine hydrochloride and 1.0% cyclopentolate hydrochloride, and the left eye received only 1.0% cyclopentolate hydrochloride. Non‐cycloplegic and cycloplegic refractive error (at 0, 10, 20 and 30 min) was measured using a binocular, open‐field autorefractometer. Data were analysed through paired t ‐tests, concordance analysis, linear regression, equivalence testing and Bland–Altman analysis, using the 95% limits of agreement.
Results
Mean spherical equivalent refraction (SER) (SD) in the right eye at 0‐, 10‐, 20‐ and 30‐min post‐instillation was 0.62 (1.45) D, 1.52 (1.80) D, 1.64 (1.81) D and 1.72 (1.80) D, respectively. Mean left eye SER (SD) were 0.68 (1.24) D, 1.42 (1.66) D, 1.56 (1.66) D and 1.68 (1.72) D, respectively. Bland–Altman analysis showed a high level of agreement, and equivalence testing confirmed that there was no clinically significant difference in SER at 20 and 30 min in both eyes (within ±0.50 D), with mean differences of 0.08 (0.23) D in the right eye and 0.13 (0.30) D in the left eye ( p = 0.21). However, SER at 10 and 30 min were equivalent in the right eye only.
Conclusions
Accurate autorefraction values can be obtained 20‐min post‐instillation of 1.0% cyclopentolate in white children aged 6–7 years, potentially reducing clinical testing times. Proxymetacaine pre‐instillation allows for reliable measurements as early as 10‐min post‐instillation of cyclopentolate. Further research is needed to validate these findings in non‐White populations and to determine the safe discharge time post‐proxymetacaine instillation.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- School of Physics, Clinical & Optometric Sciences, Centre for Eye Research Ireland, Sustainability & Health Research Centre, Technological University Dublin, Dublin, Ireland.
ORCID-Profile: Megan Doyle, Veronica O'Dwyer, Síofra Harrington
Förderung
- Optometry Ireland
- Technological University Dublin Fiosraigh Scholarship
Zitieren
APA
Doyle, M., O'Dwyer, V., & Harrington, S. (2025). Impact of proxymetacaine on the dynamics of cyclopentolate in White 6‐ to 7‐year‐olds. Ophthalmic and Physiological Optics, 45(1), 4-13. https://doi.org/10.1111/opo.13421
Vancouver
Doyle M, O'Dwyer V, Harrington S. Impact of proxymetacaine on the dynamics of cyclopentolate in White 6‐ to 7‐year‐olds. Ophthalmic and Physiological Optics. 2025;45(1):4-13. doi:10.1111/opo.13421
BibTeX
@article{Doyle2025,
author = {Doyle, Megan and O'Dwyer, Veronica and Harrington, Síofra},
title = {Impact of proxymetacaine on the dynamics of cyclopentolate in White 6‐ to 7‐year‐olds},
journal = {Ophthalmic and Physiological Optics},
year = {2025},
volume = {45},
number = {1},
pages = {4--13},