EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC-ND 4.0

Impact of blur on clinical and occupational colour vision test results

Leticia Álvaro iD, Monika A Formankiewicz iD, Sarah J Waugh iD

Ophthalmic and Physiological Optics · 2024

DOI: 10.1111/opo.13350 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Ophthalmic and Physiological Optics, 2024. Verfasst von Leticia Álvaro und 2 weiteren Autor:innen. Beteiligte Einrichtung: Departamento Psicología Experimental, Procesos Cognitivos y Logopedia, Universidad Complutense de Madrid, Pozuelo de Alarcón, Spain. Hauptthemen laut MEDLINE: Color Perception Tests, Visual Acuity, Color Vision Defects, Color Vision. Die Arbeit nennt 65 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0). Gefördert von: University of Huddersfield, HEFCE QR (Quality Related) Funds (Anglia Ruskin University).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

To evaluate whether colour vision normal (CVN) adults pass two Fletcher–Evans (CAM) lantern tests and to investigate the impact of imposed blur on Ishihara, CAM lantern and computerised colour discrimination test (colour assessment and diagnosis test [CAD] and Cambridge colour test [CCT]) results.

Methods

In a pilot experiment, 20 (16 CVN and 4 colour vision deficient [CVD]) participants with normal VA were tested with the CAM lantern. In the main experiment, the impact of imposed dioptric blur (up to +8.00 D) on visual acuity and the Ishihara test, CAM lantern, CAD and CCT was assessed for 15 CVN participants.

Results

CVN participants can fail the CAM lantern, with specificity of 81.25% (aviation mode) and 75% (clinical mode), despite following the test requirements of participants having at least 0.18 logMAR (6/9) in the better eye. With blur, test accuracy was affected. As expected, significant detrimental effects of blur on test results were found for logMAR VA and CAM lantern (aviation) with +1.00 D or higher. Ishihara, CAD and CCT results were not detrimentally affected until +8.00 D. Yellow‐blue discrimination was more affected by blur for the CAD than the CCT, which was not explained by the different colour spaces used or vectors tested.

Conclusion

False‐positive findings on lantern colour vision tests with small apertures are likely to be increased in patients with blur due to uncorrected refractive error or ocular and visual pathway disease. Other colour vision tests with larger stimuli are more robust to blur.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Color Perception TestsVisual AcuityColor Vision DefectsColor VisionHumansAdultMaleFemaleYoung AdultPilot ProjectsColor PerceptionMiddle AgedReproducibility of Results

Stichwörter der Autor:innen

CAD testCCTIshihara testcolour vision testinglantern testsrefractive bluruncorrected refractive error

Autor:innen und Institutionen

  • Departamento Psicología Experimental, Procesos Cognitivos y Logopedia, Universidad Complutense de Madrid, Pozuelo de Alarcón, Spain.
  • Vision and Hearing Sciences Research Centre, School of Psychology and Sports Science, Anglia Ruskin University, Cambridge, UK.
  • Centre for Vision across the Life Span, School of Applied Sciences, University of Huddersfield, Huddersfield, UK.

ORCID-Profile: Leticia Álvaro, Monika A Formankiewicz, Sarah J Waugh

Förderung

  • University of Huddersfield
  • HEFCE QR (Quality Related) Funds (Anglia Ruskin University)

Zitieren

APA

Álvaro, L., Formankiewicz, M. A., & Waugh, S. J. (2024). Impact of blur on clinical and occupational colour vision test results. Ophthalmic and Physiological Optics. https://doi.org/10.1111/opo.13350

Vancouver

Álvaro L, Formankiewicz MA, Waugh SJ. Impact of blur on clinical and occupational colour vision test results. Ophthalmic and Physiological Optics. 2024. doi:10.1111/opo.13350

BibTeX
@article{lvaro2024,
  author = {Álvaro, Leticia and Formankiewicz, Monika A and Waugh, Sarah J},
  title = {Impact of blur on clinical and occupational colour vision test results},
  journal = {Ophthalmic and Physiological Optics},
  year = {2024},
  doi = {10.1111/opo.13350}
}
Kostenlos starten →