Fachartikel in der Zeitschrift Ophthalmic and Physiological Optics, 2024. Verfasst von Anh Bui und 6 weiteren Autor:innen. Beteiligte Einrichtung: The Ohio State University College of Optometry, Columbus, Ohio, USA. Hauptthemen laut MEDLINE: Hyperopia, Astigmatism, Anisometropia, Refractive Errors. Die Arbeit wurde bisher 8-mal zitiert (Crossref) und nennt 41 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0). Gefördert von: Ohio Lions Eye Research Foundation.
Themen: Kinderkrankenpflege
Abstract (Originalsprache)
Purpose
This study evaluated the ability of QuickSee to detect children at risk for significant vision conditions (significant refractive error [RE], amblyopia and strabismus).
Methods
Non‐cycloplegic refraction (using QuickSee without and with +2 dioptre (D) fogging lenses) and unaided binocular near visual acuity (VA) were measured in 4‐ to 12‐year‐old children. Eye examination findings (VA, cover testing and cycloplegic retinoscopy) were used to determine the presence of vision conditions. QuickSee performance was summarised by area under the receiver operating characteristic curve (AUC), sensitivity and specificity for various levels of RE. QuickSee referral criteria for each vision condition were chosen to maximise sensitivity at a specificity of approximately 85%–90%. Sensitivity and specificity to detect vision conditions were calculated using multiple criteria. Logistic regression was used to evaluate the benefit of adding near VA (6/12 or worse) for detecting hyperopia. A paired t ‐test compared QuickSee without and with fogging lenses.
Results
The mean age was 8.2 (±2.5) years ( n = 174). RE ranged up to 9.25 D myopia, 8 D hyperopia, 5.25 D astigmatism and 3.5 D anisometropia. The testability of the QuickSee was 94.3%. AUC was ≥0.92 (excellent) for each level of RE. For the detection of any RE, sensitivity and specificity were 84.2% and 87.3%, respectively, using modified Orinda criteria and 94.5% and 78.2%, respectively, using the American Academy for Pediatric Ophthalmology and Strabismus (AAPOS) guidelines. For the detection of any significant vision condition, the sensitivity and specificity of QuickSee were 81.1% and 87.9%, respectively, using modified Orinda criteria and 93% and 78.6%, respectively, using AAPOS criteria. There was no significant benefit of adding near VA to QuickSee for the detection of hyperopia ≥+2.00 ( p = 0.34). There was no significant difference between QuickSee measurements of hyperopic refractive error with and without fogging lenses (difference = −0.09 D; p = 0.51).
Conclusions
QuickSee had high discriminatory power for detecting children with hyperopia, myopia, astigmatism, anisometropia, any significant refractive error or any significant vision condition.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- The Ohio State University College of Optometry, Columbus, Ohio, USA.
ORCID-Profile: Anh Bui, G Lynn Mitchell, Ann Morrison, Andrew Toole, Marjean T Kulp
Förderung
- Ohio Lions Eye Research Foundation
Zitieren
APA
Bui, A., Mitchell, G. L., McDaniel, C., Morrison, A., Toole, A., Buckland, M., & Kulp, M. T. (2024). Detection of significant vision conditions in children using QuickSee wavefront autorefractor. Ophthalmic and Physiological Optics. https://doi.org/10.1111/opo.13301
Vancouver
Bui A, Mitchell GL, McDaniel C, Morrison A, Toole A, Buckland M, et al. Detection of significant vision conditions in children using QuickSee wavefront autorefractor. Ophthalmic and Physiological Optics. 2024. doi:10.1111/opo.13301
BibTeX
@article{Bui2024,
author = {Bui, Anh and Mitchell, G Lynn and McDaniel, Catherine and Morrison, Ann and Toole, Andrew and Buckland, Michelle and Kulp, Marjean T},
title = {Detection of significant vision conditions in children using QuickSee wavefront autorefractor},
journal = {Ophthalmic and Physiological Optics},
year = {2024},
doi = {10.1111/opo.13301}
}
EUVIMED