One‐year results for myopia control with aspheric base curve orthokeratology lenses: A prospective randomised clinical trial
Ophthalmic and Physiological Optics · 2023-11 · 43 (6) · 1469-1477
DOI: 10.1111/opo.13213 ↗Kurz gefasst
Randomisierte kontrollierte Studie in der Zeitschrift Ophthalmic and Physiological Optics, online erschienen am 16.08.2023. Verfasst von Tong Liu und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Optometry and Vision Science, West China School of Medicine, Sichuan University, Chengdu, China. Hauptthemen laut MEDLINE: Myopia, Orthokeratologic Procedures, Refraction, Ocular, Contact Lenses. Die Arbeit wurde bisher 17-mal zitiert (Crossref) und nennt 56 Literaturangaben. Gefördert von: National Natural Science Foundation of China, Post-Doctoral Research Project, West China Hospital, Sichuan University, Collaborative Research Agreement between West China Hospital, Sichuan University and Eyebright Corporation (Beijing).
Abstract (Originalsprache)
Purpose
To compare the effect of orthokeratology (ortho‐k) using aspheric or spherical base curve (BCA vs. BCS) contact lenses on axial elongation and the relative peripheral refraction change (RPRC) in Chinese children.
Methods
Children aged 8–12 years with myopia between −0.75 and −4.00 D and astigmatism ≤1.00 D were randomly assigned to the BCA or BCS group. Peripheral refraction was assessed at 10°, 20° and 30° along the temporal and nasal retina at baseline and at the 12‐month visit. Axial length (AL) was measured under cycloplegia at baseline and at the 6‐ and 12‐month visits. Only right eye data were analysed. Repeated‐measures analysis of covariance was performed to examine the differences in axial elongation and the RPRC between the BCA and BCS groups.
Results
The 1‐year results from 31 BCA and 32 BCS subjects were analysed. No significant between‐group differences were found at baseline ( p ≥ 0.28). At the 12‐month visit, the BCA lens produced a greater absolute RPRC along the horizontal meridian than the BCS lens ( p < 0.001). Axial elongation was slower in the BCA group (0.19 ± 0.20 mm) than in the BCS group (0.29 ± 0.14 mm; p = 0.03). Axial elongation was correlated with the RPRC at 10° ( r = 0.43, p = 0.02) and 20° ( r = 0.39, p = 0.03) along the temporal retina in the BCA group; however, these correlations were not observed in the BCS group.
Conclusion
The BCA ortho‐k lens could improve the efficacy of slowing axial elongation in children. The improved myopia control observed in the BCA group may be the result of a larger myopic shift in relative peripheral refraction within 20° along the temporal retina.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Optometry and Vision Science, West China School of Medicine, Sichuan University, Chengdu, China.
- Department of Ophthalmology, West China Hospital, Sichuan University, Chengdu, China.
- Laboratory of Optometry and Vision Sciences, West China Hospital, Sichuan University, Chengdu, China.
ORCID-Profile: Tong Liu, Longqian Liu
Förderung
- National Natural Science Foundation of China
- Post-Doctoral Research Project, West China Hospital, Sichuan University
- Collaborative Research Agreement between West China Hospital, Sichuan University and Eyebright Corporation (Beijing)
Zitieren
APA
Liu, T., Chen, C., Ma, W., Yang, B., Wang, X., & Liu, L. (2023). One‐year results for myopia control with aspheric base curve orthokeratology lenses: A prospective randomised clinical trial. Ophthalmic and Physiological Optics, 43(6), 1469-1477. https://doi.org/10.1111/opo.13213
Vancouver
Liu T, Chen C, Ma W, Yang B, Wang X, Liu L. One‐year results for myopia control with aspheric base curve orthokeratology lenses: A prospective randomised clinical trial. Ophthalmic and Physiological Optics. 2023;43(6):1469-1477. doi:10.1111/opo.13213
BibTeX
@article{Liu2023,
author = {Liu, Tong and Chen, Changxu and Ma, Wei and Yang, Bi and Wang, Xi and Liu, Longqian},
title = {One‐year results for myopia control with aspheric base curve orthokeratology lenses: A prospective randomised clinical trial},
journal = {Ophthalmic and Physiological Optics},
year = {2023},
volume = {43},
number = {6},
pages = {1469--1477},
doi = {10.1111/opo.13213}
}
EUVIMED