EUVIMEDEUVIMED entdecken
Crossref

Assessing low vision care and the utilisation of optical low vision aids among patients with visual impairment in Taiwan

Ching-Ying Cheng, Min-Muh Sheu, Po-Sen Chen, Yi-Ting Chuang, Hong-Ming Cheng, Hsi-Pao Hsieh iD

Ophthalmic and Physiological Optics · 2023

DOI: 10.1111/opo.13205 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Ophthalmic and Physiological Optics, 2023. Verfasst von Ching-Ying Cheng und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Optometry, Chung Shan Medical University, Taichung, Taiwan. Hauptthemen laut MEDLINE: Visual Acuity, Vision, Low, Eyeglasses, Persons with Visual Disabilities. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 28 Literaturangaben. Gefördert von: Chung Shan Medical University.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

The aim of this study was to examine the quality of assessment and the utilisation of optical low vision aids (OLVAs) among people with visual impairment (VI) in Taiwan.

Methods

The study included 577 participants between 4 and 100 years of age (314 males and 263 females). All participants had been certified by the Ministry of the Interior of Taiwan, indicating that they had undergone a thorough and comprehensive low vision assessment, including evaluation of visual acuity (VA), contrast sensitivity, colour vision, visual fields and glare disability. Furthermore, all participants who consented to refraction had received prescriptions for OLVAs.

Result

All participants were prescribed one or more OLVAs such as eyeglasses, tinted lenses, magnifiers, closed‐circuit television magnifiers, telescopes, or screen magnifiers. Among the 577 individuals, 515 received correction for refractive errors, providing the best‐corrected VA (BCVA). The improvement in VA was significant at both distance and near, improving from 1.29 ± 0.55 to 1.01 ± 0.52 logMAR ( p < 0.001) and from 1.29 ± 0.56 to 1.01 ± 0.52 logMAR ( p < 0.001), respectively. Eyeglasses were the primary OLVAs chosen by 333 participants (64.7%), while 53.3%–80.3% of participants combined eyeglasses with other OLVAs to enhance their visual performance.

Conclusions

The most commonly used and effective OLVA was eyeglasses. Skilfully utilising appropriate refractive and VA measurements is crucial for determining the most suitable and beneficial OLVA for individuals with VI.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Visual AcuityVision, LowEyeglassesPersons with Visual DisabilitiesHumansMaleTaiwanFemaleMiddle AgedAdultChildAgedAdolescentYoung AdultChild, PreschoolAged, 80 and overContrast SensitivityVisual Fields

Stichwörter der Autor:innen

best-corrected visual acuityoptical low vision aidsrefractive correctionvisual impairments

Autor:innen und Institutionen

  • Department of Optometry, Chung Shan Medical University, Taichung, Taiwan.
  • Department of Ophthalmology, Chung Shan Medical University Hospital, Taichung, Taiwan.
  • Department of Ophthalmology, Mennonite Christian Hospital, Hualien, Taiwan.
  • Eye Health Promotion Centre of Eastern Taiwan, Hualien, Taiwan.
  • Department of Optometry, Asia University, Taichung, Taiwan.
  • Department of Special Education, National Taiwan Normal University, Taipei, Taiwan.

ORCID-Profile: Hsi-Pao Hsieh

Förderung

  • Chung Shan Medical University

Zitieren

APA

Cheng, C. Y., Sheu, M. M., Chen, P. S., Chuang, Y. T., Cheng, H. M., & Hsieh, H. P. (2023). Assessing low vision care and the utilisation of optical low vision aids among patients with visual impairment in Taiwan. Ophthalmic and Physiological Optics. https://doi.org/10.1111/opo.13205

Vancouver

Cheng CY, Sheu MM, Chen PS, Chuang YT, Cheng HM, Hsieh HP. Assessing low vision care and the utilisation of optical low vision aids among patients with visual impairment in Taiwan. Ophthalmic and Physiological Optics. 2023. doi:10.1111/opo.13205

BibTeX
@article{Cheng2023,
  author = {Cheng, Ching-Ying and Sheu, Min-Muh and Chen, Po-Sen and Chuang, Yi-Ting and Cheng, Hong-Ming and Hsieh, Hsi-Pao},
  title = {Assessing low vision care and the utilisation of optical low vision aids among patients with visual impairment in Taiwan},
  journal = {Ophthalmic and Physiological Optics},
  year = {2023},
  doi = {10.1111/opo.13205}
}
Kostenlos starten →