Neural binocular summation and the effect of defocus on the pattern electroretinogram and visual evoked potentials for different pupil sizes
Ophthalmic and Physiological Optics · 2023
DOI: 10.1111/opo.13204 ↗Kurz gefasst
Fachartikel in der Zeitschrift Ophthalmic and Physiological Optics, 2023. Verfasst von Francesco Martino und 4 weiteren Autor:innen. Beteiligte Einrichtung: Laboratory of Vision Sciences and Applications (LabVisGra), Department of Optics, University of Granada, Granada, Spain. Hauptthemen laut MEDLINE: Evoked Potentials, Visual, Electroretinography, Pupil, Vision, Binocular. Die Arbeit nennt 55 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0). Gefördert von: Consejería de Transformación Económica, Industria, Conocimiento y Universidades, Fundação para a Ciência e a Tecnologia.
Abstract (Originalsprache)
Purpose
To evaluate the influence of defocus and pupil size on subjective (visual acuity [VA]) and objective (electrophysiology) descriptors of human vision and their effect on binocular visual performance by means of neural binocular summation (BS).
Methods
Fifteen healthy young subjects were recruited in this crossover study. Pattern electroretinogram (PERG) and visual evoked potentials (VEP) were measured under two levels of positive (+1.5 and +3.0 D) spherical and astigmatic defocus (axis 90°). Pupil size was controlled to reduce the inter‐individual variability factor.
Results
Low‐ and high‐contrast VA showed poorer visual performance in the monocular versus the binocular condition. Positive BS (for VA) was higher with greater pupil size and higher levels of defocus. In the visual electrophysiology tests (i.e., VEP and PERG), peak time and amplitude were affected by pupil size and defocus. The increase in peak time was larger and the reduction in amplitude was more significant with greater levels of defocus and smaller pupil sizes. For the VEP, positive BS was found in all conditions, being stronger with larger amounts of defocus and pupil size (for the P100 amplitude). Significant negative correlations were observed between the P100 amplitude and VA BSs.
Conclusion
Smaller pupil size and levels of defocus produced greater changes in cortical activity as evidenced by both the PERG and VEP. Considering these changes and the obtained positive BS, the mechanism could be initiated as early as the retinal processing stage, then being modulated and enhanced along the visual pathway and within the visual cortex.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Laboratory of Vision Sciences and Applications (LabVisGra), Department of Optics, University of Granada, Granada, Spain.
- Clinical and Experimental Optometry Research Laboratory (CEORLab), Optometry and Vision Science, Department and Centre of Physics, University of Minho, Braga, Portugal.
ORCID-Profile: Francesco Martino, Ana Amorim-de-Sousa, Paulo Fernandes, José Juan Castro-Torres, José Manuel González-Méijome
Förderung
- Consejería de Transformación Económica, Industria, Conocimiento y Universidades
- Fundação para a Ciência e a Tecnologia
Zitieren
APA
Martino, F., Amorim-de-Sousa, A., Fernandes, P., Castro-Torres, J. J., & González-Méijome, J. M. (2023). Neural binocular summation and the effect of defocus on the pattern electroretinogram and visual evoked potentials for different pupil sizes. Ophthalmic and Physiological Optics. https://doi.org/10.1111/opo.13204
Vancouver
Martino F, Amorim-de-Sousa A, Fernandes P, Castro-Torres JJ, González-Méijome JM. Neural binocular summation and the effect of defocus on the pattern electroretinogram and visual evoked potentials for different pupil sizes. Ophthalmic and Physiological Optics. 2023. doi:10.1111/opo.13204
BibTeX
@article{Martino2023,
author = {Martino, Francesco and Amorim-de-Sousa, Ana and Fernandes, Paulo and Castro-Torres, José Juan and González-Méijome, José Manuel},
title = {Neural binocular summation and the effect of defocus on the pattern electroretinogram and visual evoked potentials for different pupil sizes},
journal = {Ophthalmic and Physiological Optics},
year = {2023},
doi = {10.1111/opo.13204}
}
EUVIMED