Dual‐focus contact lenses for myopia control modify central retinal electrophysiology in humans
Ophthalmic and Physiological Optics · 2023-09 · 43 (5) · 1100-1109
DOI: 10.1111/opo.13163 ↗Kurz gefasst
Fachartikel in der Zeitschrift Ophthalmic and Physiological Optics, online erschienen am 15.05.2023. Verfasst von Philip R K Turnbull und 2 weiteren Autor:innen. Beteiligte Einrichtung: Myopia Laboratory, School of Optometry and Vision Science, The University of Auckland, Auckland, New Zealand. Hauptthemen laut MEDLINE: Myopia, Contact Lenses, Contact Lenses, Hydrophilic. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 45 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).
Abstract (Originalsprache)
Introduction
Dual‐focus contact lenses create two focal planes, one providing a clear retinal image while the other imposes myopic defocus on the retina to slow myopia progression. This study used global‐flash multifocal electroretinogram (gmfERG) response amplitudes to compare central versus peripheral retinal responses under dual‐focus conditions and to assess the optimal degree of myopic defocus compared with a single‐vision control lens.
Methods
Twenty participants each underwent three gmfERG trials, wearing a spectacle correction over dual‐focus contact lenses with plano central power and peripheral secondary focal powers of either +2.00D, +4.00D or a plano single‐vision lens. We compared amplitudes and latencies of the gmfERG direct and induced components (DC and IC) within participants, between the three different contact lens powers and at different retinal eccentricities (gmfERG ring).
Results
We observed significant differences in the gmfERG responses between the single‐vision and dual‐focus contact lenses. Overall, DC amplitudes peaked between zero and +2.00D secondary power, while IC amplitudes were maximal between +2.00D and +4.00D. Compared with the single‐vision control, the greatest increase in DC and IC amplitudes while wearing dual‐focus lenses occurred within the central 10° of the retina. There was no interaction effect between gmfERG ring (eccentricity) and secondary power, and no difference in the latency of the gmfERG responses between different powers.
Conclusion
We found that dual‐focus contact lenses with a +2.00D secondary power are close to that expected to induce the greatest increase in gmfERG responses relative to a single‐vision lens. Dual‐focus lenses produced the highest DC and IC response amplitudes relative to a single‐vision lens in the central 10° of the retina. This suggests that dual‐focus contact lenses slow myopia progression by modifying central rather than peripheral retinal activity.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Myopia Laboratory, School of Optometry and Vision Science, The University of Auckland, Auckland, New Zealand.
- Department of Optometry, Asia University, Taichung, Taiwan.
ORCID-Profile: Philip R K Turnbull, Lucy K Goodman, John R Phillips
Zitieren
APA
Turnbull, P. R. K., Goodman, L. K., & Phillips, J. R. (2023). Dual‐focus contact lenses for myopia control modify central retinal electrophysiology in humans. Ophthalmic and Physiological Optics, 43(5), 1100-1109. https://doi.org/10.1111/opo.13163
Vancouver
Turnbull PRK, Goodman LK, Phillips JR. Dual‐focus contact lenses for myopia control modify central retinal electrophysiology in humans. Ophthalmic and Physiological Optics. 2023;43(5):1100-1109. doi:10.1111/opo.13163
BibTeX
@article{Turnbull2023,
author = {Turnbull, Philip R K and Goodman, Lucy K and Phillips, John R},
title = {Dual‐focus contact lenses for myopia control modify central retinal electrophysiology in humans},
journal = {Ophthalmic and Physiological Optics},
year = {2023},
volume = {43},
number = {5},
pages = {1100--1109},
doi = {10.1111/opo.13163}
}
EUVIMED