Timed Up‐and‐Go Test and Sit‐to‐Stand Test in Community‐Dwelling Older Person: Inter and Intraobserver Reliability Among Turkish Nurses
International Journal of Older People Nursing · 2024
DOI: 10.1111/opn.12649 ↗Kurz gefasst
Fachartikel in der Zeitschrift International Journal of Older People Nursing, 2024. Verfasst von Behire Sancar und 2 weiteren Autor:innen. Beteiligte Einrichtung: Department of Nursing, Faculty of Health Science, Toros University, Mersin, Turkey. Hauptthemen laut MEDLINE: Independent Living, Geriatric Assessment, Postural Balance. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 32 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).
Abstract (Originalsprache)
Background
A decrease in dynamic balance and muscle strength related to ageing is associated with a decreased quality of life, reduced life expectancy and increased risk of falls. Timed stand‐up test (TUG) is one of the most used clinical tests for the evaluation of dynamic balance and sit‐to‐stand test (STS). Although these tests are reported to be reliable in pathological conditions in different populations and different countries, there is a gap in the evaluation of the reliability of the tests by nurses in the older persons living in Turkish society.
Objective
The present study aimed to investigate the inter‐ and intra‐observer reliability of the timed up‐and‐go test (TUG) and sit‐to‐stand test (STS) performed by nurses in Turkish community‐dwelling older persons.
Methods
A total of 97 community‐dwelling older persons participated in this study. To determine the interobserver reliability of the TUG and STS tests, all tests were performed at an interval of 30 min by two nurses. To determine the intra‐observer reliability of the tests, each measurement was repeated 1 week after the first measurement by another nurse.
Results
Excellent intra‐observer reliability was found for the TUG (intraclass correlation coefficient [ICC] = 0.962) and STS tests (ICC = 0.996), with a total range of 0.943–0.997. Excellent interobserver reliability was found for the TUG (ICC = 0.995) and STS (ICC = 0.996) tests. The coefficient of variant values for the tests was < 15%.
Conclusion
Our results demonstrated that the TUG and STS tests can be reliably used by nurses in community‐dwelling older persons.
Implications for Practice
This study is important in terms of determining the risk of falling among older persons aged 60 and over in Turkey, preventing hospitalisations due to falls and developing nursing policies that promote the safety of older persons individuals.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Nursing, Faculty of Health Science, Toros University, Mersin, Turkey.
- Department of Physical Therapy and Rehabilitation, Faculty of Health Science, Toros University, Mersin, Turkey.
ORCID-Profile: Behire Sancar, Aysel Doğan, Serkan Taş
Zitieren
APA
Sancar, B., Doğan, A., & Taş, S. (2024). Timed Up‐and‐Go Test and Sit‐to‐Stand Test in Community‐Dwelling Older Person: Inter and Intraobserver Reliability Among Turkish Nurses. International Journal of Older People Nursing. https://doi.org/10.1111/opn.12649
Vancouver
Sancar B, Doğan A, Taş S. Timed Up‐and‐Go Test and Sit‐to‐Stand Test in Community‐Dwelling Older Person: Inter and Intraobserver Reliability Among Turkish Nurses. International Journal of Older People Nursing. 2024. doi:10.1111/opn.12649
BibTeX
@article{Sancar2024,
author = {Sancar, Behire and Doğan, Aysel and Taş, Serkan},
title = {Timed Up‐and‐Go Test and Sit‐to‐Stand Test in Community‐Dwelling Older Person: Inter and Intraobserver Reliability Among Turkish Nurses},
journal = {International Journal of Older People Nursing},
year = {2024},
doi = {10.1111/opn.12649}
}
EUVIMED