Efficiency of multi‐strand steel, superelastic Ni‐Ti and ion‐implanted Ni‐Ti archwires for initial alignment
Clinical Orthodontics and Research · 1998-08 · 1 (1) · 12-19
DOI: 10.1111/ocr.1998.1.1.12 ↗Kurz gefasst
Klinische Studie in der Zeitschrift Clinical Orthodontics and Research, online erschienen am 09.02.2018. Verfasst von N W Cobb und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Orthodontics, University of North Carolina, School of Dentistry, Chapel Hill 27599-7450, USA. Hauptthemen laut MEDLINE: Dental Alloys, Nickel, Orthodontic Appliance Design, Orthodontic Wires. Die Arbeit wurde bisher 47-mal zitiert (Crossref).
Abstract (Originalsprache)
In a clinical trial involving 155 dental arches with irregularity > 5 mm, the rate of alignment was used to compare the alignment efficiency of 16 mil superelastic Ni‐Ti versus 17.5 mil triple‐stranded steel archwires, and to determine whether ion implantation of the Ni‐Ti wire improved its performance. Subjects were randomly assigned to archwire types; both 18 and 22 slot edgewise appliances were employed. Pre‐treatment equivalence of the experimental groups was verified. Anterior irregularity was determined monthly (using Little's irregularity index) until it decreased below 2 mm, and the elastomeric ligatures were replaced at each appointment. Effective tooth movement occurred with each of the archwire types. There were no significant differences among wires, but the rate of alignment was significantly faster in the lower arch for subjects with the 22 slot appliance.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Substanzen
Autor:innen und Institutionen
- Department of Orthodontics, University of North Carolina, School of Dentistry, Chapel Hill 27599-7450, USA.
Zitieren
APA
Cobb, N. W., Kula, K. S., Phillips, C., & Proffit, W. R. (1998). Efficiency of multi‐strand steel, superelastic Ni‐Ti and ion‐implanted Ni‐Ti archwires for initial alignment. Clinical Orthodontics and Research, 1(1), 12-19. https://doi.org/10.1111/ocr.1998.1.1.12
Vancouver
Cobb NW, Kula KS, Phillips C, Proffit WR. Efficiency of multi‐strand steel, superelastic Ni‐Ti and ion‐implanted Ni‐Ti archwires for initial alignment. Clinical Orthodontics and Research. 1998;1(1):12-19. doi:10.1111/ocr.1998.1.1.12
BibTeX
@article{Cobb1998,
author = {Cobb, N W and Kula, K S and Phillips, C and Proffit, W R},
title = {Efficiency of multi‐strand steel, superelastic Ni‐Ti and ion‐implanted Ni‐Ti archwires for initial alignment},
journal = {Clinical Orthodontics and Research},
year = {1998},
volume = {1},
number = {1},
pages = {12--19},
doi = {10.1111/ocr.1998.1.1.12}
}