Mandibular molar protraction: A comparison between fixed functional appliances and temporary anchorage devices
Orthodontics & Craniofacial Research · 2024
DOI: 10.1111/ocr.12790 ↗Kurz gefasst
Vergleichsstudie in der Zeitschrift Orthodontics & Craniofacial Research, 2024. Verfasst von Abdulrahman Alshehri und 5 weiteren Autor:innen. Beteiligte Einrichtung: Division of Orthodontics, Department of Preventive Dental Sciences, College of Dentistry, Jazan University, Jazan, Saudi Arabia. Hauptthemen laut MEDLINE: Orthodontic Anchorage Procedures, Molar, Tooth Movement Techniques, Mandible. Die Arbeit wurde bisher 7-mal zitiert (Crossref) und nennt 39 Literaturangaben.
Abstract (Originalsprache)
Introduction
This study aimed to compare the efficiency of temporary anchorage devices (TADs) and fixed functional appliances (FFAs) for mandibular molar protraction.
Methods
Orthodontic records of 1050 consecutively treated patients with molar protraction were screened. Thirty‐six records (22 females and 14 males; mean age, 17.4 years) were divided into two groups: TAD (21 subjects with 25 edentulous spaces) and FFA (15 subjects with 24 edentulous spaces). The primary outcome measure was the efficiency of protraction [magnitude and time required for protraction (rate) and anchor loss (AL)]. The secondary outcomes involved measuring the type of tooth movement (TOTM), external apical root resorption (EARR), alveolar bone height change (ABHC), alveolar bone width change (ABWC) and appliance failure.
Results
The rate of tooth movement was significantly higher for FFAs (0.83 ± 0.35 mm/month) versus TADs (0.49 ± 0.2 mm/month) ( P = .005). Total treatment duration was less for FFAs (34.78 ± 8.1 months) versus TADs (47.72 ± 13.94 months) ( P = .002). TOTM was similar for both ( P = .909). EARR was 1.42 ± 1.38 mm for TAD and 1.25 ± 0.88 mm for FFA ( P = .81). ABHC increased in the FFA group (1.01 ± 3.62 mm) and decreased for the TAD group (0.68 ± 1.66 mm). ABWC increased for both TAD (1.81 ± 1.73 mm) and FFA (1.75 ± 1.35 mm). The failure rate was 50% for FFAs and 33% for TADs.
Conclusions
Both systems provided translation of lower molars with comparable anchorage control. However, FFAs were more efficient than TADs for lower molar protraction.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Division of Orthodontics, Department of Preventive Dental Sciences, College of Dentistry, Jazan University, Jazan, Saudi Arabia.
- Department of Orthodontics, University of Florida, Gainesville, Florida, USA.
- Private Practice, Fort Wayne, Indiana, USA.
- Private Practice, Norwalk, Ohio, USA.
- Department of Growth and Development, UNMC, College of Dentistry, Omaha, Nebraska, USA.
- Division of Orthodontics UConn Health, Farmington, Connecticut, USA.
ORCID-Profile: Abdulrahman Alshehri, Sarah Abu Arqub, Sumit Yadav, Madhur Upadhyay
Zitieren
APA
Alshehri, A., Abu Arqub, S., Betlej, A., Chhibber, A., Yadav, S., & Upadhyay, M. (2024). Mandibular molar protraction: A comparison between fixed functional appliances and temporary anchorage devices. Orthodontics & Craniofacial Research. https://doi.org/10.1111/ocr.12790
Vancouver
Alshehri A, Abu Arqub S, Betlej A, Chhibber A, Yadav S, Upadhyay M. Mandibular molar protraction: A comparison between fixed functional appliances and temporary anchorage devices. Orthodontics & Craniofacial Research. 2024. doi:10.1111/ocr.12790