EUVIMEDEUVIMED entdecken
Randomisierte kontrollierte Studie

Effect of functional appliances on sleep‐disordered breathing in Class II division 1 malocclusion children: Randomized controlled trial

Effect of functional appliances on sleep-disordered breathing in Class II division 1 malocclusion children: randomisierte kontrollierte Studie

E S Radwan iD, A Maher, M A Montasser iD

Orthodontics & Craniofacial Research · 2024-02 · 27 (1) · 126-138

DOI: 10.1111/ocr.12696 ↗

Auf einen Blick

Bei Kindern mit Klasse-II-Malokklusion verbesserte der Twin Block die oropharyngeale Atemwegsweite und nächtliche Atmung. Für die nasopharyngeale Atemwegsweite zeigte sich kein signifikanter Unterschied.

Fragestellung

Untersucht wurde, ob funktionelle Apparaturen die pharyngeale Atemwegsweite und die nächtliche Atmung bei Kindern mit skelettaler Klasse II durch mandibuläre Retrognathie beeinflussen.

Methode

Randomisierte kontrollierte Studie mit 40 Patient:innen; 1:1-Zuteilung zu Twin Block oder fester Apparatur; Dauer 12 Monate; Auswertung teils verblindet.

Ergebnisse

Oropharyngeales Volumen: 2,66 cc vs. 0,056; P=.03. Nasopharyngeales Volumen: 1,3 cc vs. 0,84; P=.053. ODI: median −3,55 (−5,05 bis 0,50); P≤.001. MEP: median 45 (0,0–110); P≤.001.

Schlussfolgerung der Autor:innen

Die Twin-Block-Gruppe zeigte eine signifikante Veränderung des oropharyngealen Atemwegsvolumens und eine Verbesserung der nächtlichen Atmung.

Kernaussagen

  • Twin Block verbesserte das oropharyngeale Volumen
  • ODI sank signifikant in der Twin-Block-Gruppe
  • Keine schweren unerwünschten Ereignisse beobachtet

Deutsche Zusammenfassung: KI-gestützt aus dem Original-Abstract erstellt; alle Zahlen wurden automatisch mit dem Original abgeglichen. Maßgeblich ist der Original-Abstract.

Kurz gefasst

Randomisierte kontrollierte Studie in der Zeitschrift Orthodontics & Craniofacial Research, online erschienen am 31.07.2023. Verfasst von E S Radwan und 2 weiteren Autor:innen. Beteiligte Einrichtung: Department of Orthodontics, Faculty of Dentistry, Mansoura University, Mansoura, Egypt. Hauptthemen laut MEDLINE: Malocclusion, Angle Class II, Overbite, Malocclusion, Sleep Apnea Syndromes. Die Arbeit wurde bisher 7-mal zitiert (Crossref) und nennt 40 Literaturangaben.

Auf einen BlickAbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objectives

A randomized controlled trial was undertaken to investigate the orthopaedic effect of functional appliances on the pharyngeal airway space and nocturnal breathing of children with skeletal class II due to mandibular retrusion. Materials and Methods Forty patients were randomized into a 1:1 ratio study (Twin block) group and a control (fixed appliance) group. Each group included equal numbers of boys and girls. Diagnosis with sleep‐disordered breathing was not an inclusion criterion. The duration of the trial was 12 months (T0 ‐ T12). Eligibility criteria included skeletal Class II division 1 malocclusion with mandibular retrognathism, SNA ≥82, SNB ≤78, ANB ≥4, overjet ≥6 mm, and patients in circumpubertal stage CVM2 and CVM3. The main outcomes were pharyngeal airway volume, oxygen desaturation index (ODI), and maximum expiratory pressure (MEP), while the secondary outcomes were skeletal and dental changes of the maxilla and mandible. Randomization was accomplished with random blocks of 20 patients with allocation concealed in sequentially numbered, opaque, and sealed envelopes. Blinding was only applicable for data analysis of radiographic measurements and data extracted from the pulse oximeter.

Results

The mean age of the patients was 10 ± 1.5 and 10 ± 1.2 at (T0) for the Twin Block and the control groups, respectively. The changes in the oropharyngeal (2.66 cc and 0.056; P = .03) and nasopharyngeal (1.3 cc and 0.84; P = .053) airway volumes for the Twin block and control groups, respectively, were significantly different for the oropharynx. There was a significant decrease in ODI by [median −3.55 (−5.05 to 0.50); P ≤ .001] and a significant increase [median 45 (0.0–110); P ≤ .001] in MEP for the Twin block group. A significant inverse correlation ( r = −.589; P = .006) could be found between the total volume of the oropharynx and ODI. No serious harm was observed.

Conclusions

The Twin block group showed significant change in oropharyngeal airway volume and improvement of nocturnal breathing. Registration This trial was registered at https://www.clinicaltrials.gov , registration number NCT04255511.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Malocclusion, Angle Class IIOverbiteMalocclusionSleep Apnea SyndromesOrthodontic Appliances, FunctionalMaleChildFemaleHumansMandibleMaxillaCephalometry

Stichwörter der Autor:innen

oxygen desaturation indexskeletal class IIsleep-disordered breathingtwin block

Autor:innen und Institutionen

  • Department of Orthodontics, Faculty of Dentistry, Mansoura University, Mansoura, Egypt.

ORCID-Profile: E S Radwan, M A Montasser

Zitieren

APA

Radwan, E. S., Maher, A., & Montasser, M. A. (2024). Effect of functional appliances on sleep‐disordered breathing in Class II division 1 malocclusion children: Randomized controlled trial. Orthodontics & Craniofacial Research, 27(1), 126-138. https://doi.org/10.1111/ocr.12696

Vancouver

Radwan ES, Maher A, Montasser MA. Effect of functional appliances on sleep‐disordered breathing in Class II division 1 malocclusion children: Randomized controlled trial. Orthodontics & Craniofacial Research. 2024;27(1):126-138. doi:10.1111/ocr.12696

BibTeX
@article{Radwan2024,
  author = {Radwan, E S and Maher, A and Montasser, M A},
  title = {Effect of functional appliances on sleep‐disordered breathing in Class II division 1 malocclusion children: Randomized controlled trial},
  journal = {Orthodontics & Craniofacial Research},
  year = {2024},
  volume = {27},
  number = {1},
  pages = {126--138},
  doi = {10.1111/ocr.12696}
}
Kostenlos starten →