Stomatal response to VPD is not triggered by changes in soil–leaf hydraulic conductance in Arabidopsis or Callitris
New Phytologist · 2024-04 · 242 (2) · 444-452
DOI: 10.1111/nph.19607 ↗Kurz gefasst
Fachartikel in der Zeitschrift New Phytologist, online erschienen am 23.02.2024. Verfasst von Ibrahim Bourbia und 1 weiteren Autor:innen. Beteiligte Einrichtung: School of Natural Sciences, University of Tasmania, Private Bag 55, Hobart, Tas., 7001, Australia. Hauptthemen laut MEDLINE: Arabidopsis. Die Arbeit wurde bisher 31-mal zitiert (Crossref) und nennt 42 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0). Gefördert von: Australian Research Council Centre of Excellence for Plant Success in Nature and Agriculture.
Abstract (Originalsprache)
Stomatal closure under high VPD L (leaf to air vapour pressure deficit) is a primary means by which plants prevent large excursions in transpiration rate and leaf water potential (Ψ leaf ) that could lead to tissue damage. Yet, the drivers of this response remain controversial. Changes in Ψ leaf appear to drive stomatal VPD L response, but many argue that dynamic changes in soil‐to‐leaf hydraulic conductance ( K s‐l ) make an important contribution to this response pathway, even in well‐hydrated soils. Here, we examined whether the regulation of whole plant stomatal conductance ( g c ) in response to typical changes in daytime VPD L is influenced by dynamic changes in K s‐l . We use well‐watered plants of two species with contrasting ecological and physiological features: the herbaceous Arabidopsis thaliana (ecotype Columbia‐0) and the dry forest conifer Callitris rhomboidea . The dynamics of K s‐l and g c were continuously monitored by combining concurrent in situ measurements of Ψ leaf using an open optical dendrometer and whole plant transpiration using a balance. Large changes in VPD L were imposed to induce stomatal closure and observe the impact on K s‐l . In both species, g c was observed to decline substantially as VPD L increased, while K s‐l remained stable. Our finding suggests that stomatal regulation of transpiration is not contingent on a decrease in K s‐l . Static K s‐l provides a much simpler explanation for transpiration control in hydrated plants and enables simplified modelling and new methods for monitoring plant water use in the field.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- School of Natural Sciences, University of Tasmania, Private Bag 55, Hobart, Tas., 7001, Australia.
ORCID-Profile: Ibrahim Bourbia, Timothy J Brodribb
Förderung
- Australian Research Council Centre of Excellence for Plant Success in Nature and Agriculture
Zitieren
APA
Bourbia, I., & Brodribb, T. J. (2024). Stomatal response to VPD is not triggered by changes in soil–leaf hydraulic conductance in Arabidopsis or Callitris. New Phytologist, 242(2), 444-452. https://doi.org/10.1111/nph.19607
Vancouver
Bourbia I, Brodribb TJ. Stomatal response to VPD is not triggered by changes in soil–leaf hydraulic conductance in Arabidopsis or Callitris. New Phytologist. 2024;242(2):444-452. doi:10.1111/nph.19607
BibTeX
@article{Bourbia2024,
author = {Bourbia, Ibrahim and Brodribb, Timothy J},
title = {Stomatal response to VPD is not triggered by changes in soil–leaf hydraulic conductance in Arabidopsis or Callitris},
journal = {New Phytologist},
year = {2024},
volume = {242},
number = {2},
pages = {444--452},
doi = {10.1111/nph.19607}
}
EUVIMED