EUVIMEDEUVIMED entdecken
ValidierungsstudieOpen Access · CC BY 4.0

Diagnostic Accuracy of High‐Resolution Manometry for Assessing Fundoplication Integrity: Validation of the Padova Classification

Arianna Vittori iD, Giovanni Capovilla, Matteo Santangelo, Rena Yadlapati iD, C Prakash Gyawali iD, Edoardo Vincenzo Savarino iD, Luca Provenzano iD, Francesca Forattini iD, Matteo Pittacolo, Irene Sole Zuin iD, Giulia Nezi, Loredana Nicoletti iD und 2 weitere

Neurogastroenterology & Motility · 2026-10 · 38 (10)

DOI: 10.1111/nmo.70457 ↗

Kurz gefasst

Validierungsstudie in der Zeitschrift Neurogastroenterology & Motility, online erschienen am 02.10.2026. Verfasst von Arianna Vittori und 13 weiteren Autor:innen. Beteiligte Einrichtung: Department of Surgery, Oncology and Gastroenterology, 1st General Surgery Unit, University of Padua, School of Medicine, Padua, Italy. Hauptthemen laut MEDLINE: Manometry, Fundoplication, Gastroesophageal Reflux, Postoperative Complications. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 43 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Recurrent symptoms after laparoscopic fundoplication (LF) are not fully understood, with ongoing research focusing on their mechanisms. This study aimed to validate the Padova Classification, a postoperative high‐resolution manometry (HRM) framework to distinguish functioning from defective fundoplications.

Methods

Prospectively collected data from consecutive patients who underwent post‐LF HRM (2010–2025) were analyzed and categorized as functioning and effective LF (FELF), post‐fundoplication outflow obstruction (PFOO), and ineffective neo‐barrier (INB). Primary analysis involved between‐group comparisons. Padova Classification diagnostic accuracy was evaluated against a composite reference standard (clinical, radiological, endoscopic, and pH‐monitoring criteria) by calculating sensitivity, specificity, positive predictive value, and negative predictive value for each diagnostic category. Diagnostic performance of postoperative integrated relaxation pressure (IRP) for identifying PFOO was evaluated using receiver operating characteristic curve analysis. Key Results Among 373 patients (42.4% female; median age 54 years, median BMI 25.9 kg/m 2 ; 55.2% Nissen, 44.8% Toupet), FELF, INB, and PFOO were observed in 58.7%, 21.4%, and 18.0% of patients, respectively, with PFOO most frequently seen with Nissen fundoplication ( p = 0.001). The Padova Classification showed sensitivity/specificity 94.7%/97.1% for FELF, 88.8%/96.9% for INB, and 100%/97.4% for PFOO. Postoperative integrated relaxation pressure accurately discriminated PFOO (AUC 0.959–0.984; cutoff 18.1 mmHg; sensitivity 97.7%–98.0%, specificity 93.2%–96.8%), with no difference between ROC curves derived from Padova Classification and reference standard ( p = 0.12).

Conclusions

This study confirms that the Padova Classification demonstrates strong performance in assessing postoperative LF function.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

ManometryFundoplicationGastroesophageal RefluxPostoperative ComplicationsHumansFemaleMiddle AgedMaleProspective StudiesLaparoscopyAdultAgedSensitivity and Specificity

Stichwörter der Autor:innen

fundoplicationgastroesophageal refluxmanometrysurgery

Autor:innen und Institutionen

  • Department of Surgery, Oncology and Gastroenterology, 1st General Surgery Unit, University of Padua, School of Medicine, Padua, Italy.
  • Department of Gastroenterology and Hepatology, University of California San Diego, San Diego, California, USA.
  • Division of Gastroenterology, Washington University School of Medicine, St Louis, Missouri, USA.

ORCID-Profile: Arianna Vittori, Rena Yadlapati, C Prakash Gyawali, Edoardo Vincenzo Savarino, Luca Provenzano, Francesca Forattini, Irene Sole Zuin, Loredana Nicoletti, Michele Valmasoni, Renato Salvador

Zitieren

APA

Vittori, A., Capovilla, G., Santangelo, M., Yadlapati, R., Gyawali, C. P., Savarino, E. V., Provenzano, L., Forattini, F., Pittacolo, M., Zuin, I. S., Nezi, G., Nicoletti, L., Valmasoni, M., & Salvador, R. (2026). Diagnostic Accuracy of High‐Resolution Manometry for Assessing Fundoplication Integrity: Validation of the Padova Classification. Neurogastroenterology & Motility, 38(10). https://doi.org/10.1111/nmo.70457

Vancouver

Vittori A, Capovilla G, Santangelo M, Yadlapati R, Gyawali CP, Savarino EV, et al. Diagnostic Accuracy of High‐Resolution Manometry for Assessing Fundoplication Integrity: Validation of the Padova Classification. Neurogastroenterology & Motility. 2026;38(10). doi:10.1111/nmo.70457

BibTeX
@article{Vittori2026,
  author = {Vittori, Arianna and Capovilla, Giovanni and Santangelo, Matteo and Yadlapati, Rena and Gyawali, C Prakash and Savarino, Edoardo Vincenzo and Provenzano, Luca and Forattini, Francesca and Pittacolo, Matteo and Zuin, Irene Sole and Nezi, Giulia and Nicoletti, Loredana and Valmasoni, Michele and Salvador, Renato},
  title = {Diagnostic Accuracy of High‐Resolution Manometry for Assessing Fundoplication Integrity: Validation of the Padova Classification},
  journal = {Neurogastroenterology & Motility},
  year = {2026},
  volume = {38},
  number = {10},
  doi = {10.1111/nmo.70457}
}
Kostenlos starten →