Determination of the Minimum Discard Volume in the Extraction of Blood Samples Through Arterial Catheters in Critical Patients
Nursing in Critical Care · 2026
DOI: 10.1111/nicc.70493 ↗Kurz gefasst
Fachartikel in der Zeitschrift Nursing in Critical Care, 2026. Verfasst von Patricia Morales Fernández und 7 weiteren Autor:innen. Beteiligte Einrichtung: Burn Unit, Hospital Universitario de La Paz, Madrid, Spain. Hauptthemen laut MEDLINE: Critical Illness, Blood Specimen Collection, Catheterization, Peripheral. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 31 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Background
The critically ill patient requires multiple extractions through catheters, implying a substantial blood loss. The discard method continues to be a commonly used method in Intensive Care Units. However, there is no homogeneity in practice.
Aim
Determine the minimum blood discard volume to obtain samples through radial arterial catheter. Study Design Quasi‐experimental, prospective, cross‐sectional study employing the STOBE checklist. Four consecutive arterial blood gases were performed considering the flush volume (sample A with 1 dead space discarding 1 mL, sample B with 2 discard space [2 mL], sample C with 3 discard space [3 mL] and control with 4 discard space [4 mL]). The study was approved by the Ethics and Pharmacological Research Committee of the Research Institute of La paz Hospital (Law No. 2023.564). It was conducted in the Burn Intensive Care Unit and the Resuscitation and Critical Care Unit of La Paz Hospital from September 2023 to June 2024.
Results
We found values outside the Clinical Acceptance Interval (CAI) in sample A versus control in pCO 2 (47.42%), HCO 3 − (60.71%), Haemoglobin (67.85%), Na 2+ (7.14%), K + (71.42%) and glycaemia (21.42%). In the case of lactate, no values outside the Clinical Acceptance Interval were found. When comparing sample B versus control, we found significant differences in HCO 3 − ( p = 0.027) and glycaemia ( p = 0.001). However, none of the parameters studied presented values outside the Clinical Acceptance Interval. When the results were related to the Reference Value of Change (RVC), the pCO 2 and Haemoglobin values presented 3.57% of values outside the Clinical Acceptance Interval, respectively, although they did not present statistically significant differences ( p > 0.05). When comparing sample C versus control, no significant differences were found in any parameter, nor values outside the Clinical Acceptance Interval.
Conclusions
The volume of discard required to obtain valid values is twice the volume used to purge the arterial catheterization system (2 mL) for obtaining samples for clinical use. Relevance to Clinical Practice The calculation of the minimum amount of discard in the collection of blood samples through the arterial catheter is an intervention at no extra cost that will reduce iatrogenic anaemia, reducing the need for transfusions, the complications associated with this therapy and the reduction of costs in critically ill patients.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Autor:innen und Institutionen
- Burn Unit, Hospital Universitario de La Paz, Madrid, Spain.
- Faculty of Health Sciences, Universidad Rey Juan Carlos, Alcorcón, Spain.
- Department of Intensive Care Medicine, Hospital Universitario de La Paz, Madrid, Spain.
- Data Science Laboratory, Universidad Rey Juan Carlos, Móstoles, Spain.
- Clinical Analysis Service, Hospital Universitario de La Paz, Madrid, Spain.
ORCID-Profile: Patricia Morales Fernández, Francisco Javier Castro Olmo, Sara González-Martín, Miguel Serrano Hernández, Manuel Quintana Díaz, Víctor Aceña Gil, Estefani Martínez-Chávez, Belén Fernández-Puntero
Zitieren
APA
Fernández, P. M., Olmo, F. J. C., González-Martín, S., Hernández, M. S., Díaz, M. Q., Gil, V. A., Martínez-Chávez, E., & Fernández-Puntero, B. (2026). Determination of the Minimum Discard Volume in the Extraction of Blood Samples Through Arterial Catheters in Critical Patients. Nursing in Critical Care. https://doi.org/10.1111/nicc.70493
Vancouver
Fernández PM, Olmo FJC, González-Martín S, Hernández MS, Díaz MQ, Gil VA, et al. Determination of the Minimum Discard Volume in the Extraction of Blood Samples Through Arterial Catheters in Critical Patients. Nursing in Critical Care. 2026. doi:10.1111/nicc.70493
BibTeX
@article{Fernndez2026,
author = {Fernández, Patricia Morales and Olmo, Francisco Javier Castro and González-Martín, Sara and Hernández, Miguel Serrano and Díaz, Manuel Quintana and Gil, Víctor Aceña and Martínez-Chávez, Estefani and Fernández-Puntero, Belén},
title = {Determination of the Minimum Discard Volume in the Extraction of Blood Samples Through Arterial Catheters in Critical Patients},
journal = {Nursing in Critical Care},
year = {2026},
doi = {10.1111/nicc.70493}
}
EUVIMED