EUVIMEDEUVIMED entdecken
BeobachtungsstudieOpen Access · CC BY 4.0

Accuracy and Bias of Pulse Oximetry in the Intensive Care Unit: A Prospective Observational Study

Kaio B Barros iD, Jocassia S Pinheiro, Murilo S Sampaio, Luismar B Cruz Junior iD, Fernando F Ferreira, Anibal Basile-Filho, Rinaldo R J Guirro iD, Luciano Bachmann

Nursing in Critical Care · 2026

DOI: 10.1111/nicc.70433 ↗

Kurz gefasst

Beobachtungsstudie in der Zeitschrift Nursing in Critical Care, 2026. Verfasst von Kaio B Barros und 7 weiteren Autor:innen. Beteiligte Einrichtung: Department of Physics, University of São Paulo, Ribeirão Preto, Brazil. Hauptthemen laut MEDLINE: Oximetry, Intensive Care Units, Oxygen Saturation. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 42 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Coordenação de Aperfeiçoamento de Pessoal de Nível Superio, Fundação de Apoio ao Ensino, Pesquisa e Assistência do Hospital das Clínicas da Faculdade de Medicina de Ribeirão Preto da Universidade de São Paulo, Fundação de Amparo à Pesquisa do Estado de São Paulo.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Non‐invasive oximetry is crucial for the easy and continuous monitoring of blood oxygenation, from routine assessments to critical care in intensive care units (ICU). Studies indicate that pulse oximeter readings may be biased due to the high light absorption of melanin.

Aim

This study aims to analyse the agreement among three different pulse oximeters and their concordance with arterial blood gas measurements in ICU patients and verify how accuracy varies with age and skin pigmentation. Study Design We conducted a prospective cross‐sectional observational study with a population of intensive care patients. Blood oxygen saturation was measured simultaneously by pulse oximetry and arterial blood gas analysis. Skin pigmentation was objectively assessed at two anatomical sites using calibrated colorimeters and quantified by the individual typology angle (ITA°).

Results

Among 100 ICU patients (SaO 2 85%–100%), two of the three oximeters exceeded the 3% accuracy root mean square (ARMS) 2013 FDA threshold, whereas one device remained within limits (2.91%). Agreement with arterial oxygen saturation was weak (CCC = 0.34–0.46) and lower SaO 2 was associated with overestimation increase (0.31%–0.54% for every 1% SaO 2 decrease). Multivariable models showed no evidence of association between ITA° and SpO 2 error ( p > 0.05). In contrast, older age predicted greater overestimation ( β range = 0.05%–0.06% per year; 95% CI range = 0.02–0.09; all p ≤ 0.05).

Conclusions

Although estimates suggested small pigmentation effects, analysis indicated these were indistinguishable from random error. In contrast, physiological factors such as lower SaO 2 and older age were consistently associated with greater oximeter error. Substantial clinical variability limits detection of small biases, underscoring the need for improved calibration and validation using objective skin‐tone assessment. Relevance to Clinical Practice In intensive care, where continuous monitoring is essential, pulse oximeter error was more strongly related to physiological factors, such as arterial oxygen saturation and age, than to skin tone. These findings support cautious interpretation of SpO 2 values and appropriate device selection to ensure accurate assessment across diverse populations.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

OximetryIntensive Care UnitsOxygen SaturationHumansProspective StudiesCross-Sectional StudiesFemaleMaleMiddle AgedAgedSkin PigmentationBlood Gas AnalysisOxygenReproducibility of ResultsBiasCritical CareAdult

Stichwörter der Autor:innen

oxygen saturationpulse oximetryracial biasskin colorimetry

Substanzen

Oxygen

Autor:innen und Institutionen

  • Department of Physics, University of São Paulo, Ribeirão Preto, Brazil.
  • Department of Health Science, University of São Paulo, Ribeirão Preto, Brazil.
  • Sao Carlos Institute of Physics, University of São Paulo, São Carlos, Brazil.
  • Department of Surgery and Anatomy, University of São Paulo, Ribeirão Preto, Brazil.

ORCID-Profile: Kaio B Barros, Luismar B Cruz Junior, Rinaldo R J Guirro

Förderung

  • Coordenação de Aperfeiçoamento de Pessoal de Nível Superio
  • Fundação de Apoio ao Ensino, Pesquisa e Assistência do Hospital das Clínicas da Faculdade de Medicina de Ribeirão Preto da Universidade de São Paulo
  • Fundação de Amparo à Pesquisa do Estado de São Paulo
  • Coordenação de Aperfeiçoamento de Pessoal de Nível Superior
  • Fundação de Apoio ao Ensino, Pesquisa e Assistência

Zitieren

APA

Barros, K. B., Pinheiro, J. S., Sampaio, M. S., Junior, L. B. C., Ferreira, F. F., Basile-Filho, A., Guirro, R. R. J., & Bachmann, L. (2026). Accuracy and Bias of Pulse Oximetry in the Intensive Care Unit: A Prospective Observational Study. Nursing in Critical Care. https://doi.org/10.1111/nicc.70433

Vancouver

Barros KB, Pinheiro JS, Sampaio MS, Junior LBC, Ferreira FF, Basile-Filho A, et al. Accuracy and Bias of Pulse Oximetry in the Intensive Care Unit: A Prospective Observational Study. Nursing in Critical Care. 2026. doi:10.1111/nicc.70433

BibTeX
@article{Barros2026,
  author = {Barros, Kaio B and Pinheiro, Jocassia S and Sampaio, Murilo S and Junior, Luismar B Cruz and Ferreira, Fernando F and Basile-Filho, Anibal and Guirro, Rinaldo R J and Bachmann, Luciano},
  title = {Accuracy and Bias of Pulse Oximetry in the Intensive Care Unit: A Prospective Observational Study},
  journal = {Nursing in Critical Care},
  year = {2026},
  doi = {10.1111/nicc.70433}
}
Kostenlos starten →