EUVIMEDEUVIMED entdecken
ValidierungsstudieOpen Access · CC BY-NC-ND 4.0

Development of the compliance with mechanical ventilator scale in: A validity and reliability study

Berrin Pazar iD, Hafize Savas iD, Sadık Turgut, Hayriye Cankar Dal

Nursing in Critical Care · 2025

DOI: 10.1111/nicc.13191 ↗

Kurz gefasst

Validierungsstudie in der Zeitschrift Nursing in Critical Care, 2025. Verfasst von Berrin Pazar und 3 weiteren Autor:innen. Beteiligte Einrichtung: Surgical Diseases Nursing, Faculty of Health Sciences, Lokman Hekim University, Ankara, Turkey. Hauptthemen laut MEDLINE: Respiration, Artificial, Psychometrics, Guideline Adherence. Die Arbeit nennt 44 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Mechanical ventilation is a widely used treatment modality in cardiac surgery intensive care units (ICUs), especially for patients requiring respiratory support during postoperative management.

Aim

The aim of this study was to define the process of developing a scale to assess adherence to mechanical ventilation in cardiac surgery patients and to assess the validity and reliability of the scale. Study design This is a scale development and scale validation study. The study was conducted with 222 patients between April and September 2023. In the first stage, face‐to‐face interviews were conducted with seven nurses. Based on the literature review and content analysis of the interviews, the researchers created an item pool. In the second stage, the validity and reliability of the Mechanical Ventilator Compliance Scale in cardiac surgery patients were assessed. The scale was developed to be used by nurses working in cardiac surgery ICUs.

Results

The first 36‐item scale was subjected to content validity assessment by 14 experts. It was revised according to the experts' feedback and a content validity criterion of 0.83 was obtained. Confirmatory factor analysis showed good fit values for the scale ( χ 2 /SD = 3.09, GFI = 0.90, AGFI = 0.90, CFI = 0.91, RMSEA = 0.06, and RMR = 0.07). Test‐retest analysis to assess the reliability of the scale showed good agreement between responses over time (ICC: 0.932; p < .001). Cronbach's alpha values for the scale and its subscales, behavioural and physical responses were 0.956, 0.949 and 0.912, respectively.

Conclusions

The study findings indicate that the scale is a reliable and valid tool for assessing mechanical ventilator compliance in cardiac surgery patients. Relevance for Clinical Practice This study provides nurses in cardiac surgery intensive care units with a measurement tool to objectively assess patients' compliance with mechanical ventilation therapy. The scale provides more reliable results by preventing subjective judgement and estimation in patient assessment.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Respiration, ArtificialPsychometricsGuideline AdherenceHumansReproducibility of ResultsFemaleMaleMiddle AgedIntensive Care UnitsSurveys and QuestionnairesCardiac Surgical ProceduresAdultAged

Stichwörter der Autor:innen

cardiac surgeryintensive caremechanical ventilationreliability and validityscale development

Autor:innen und Institutionen

  • Surgical Diseases Nursing, Faculty of Health Sciences, Lokman Hekim University, Ankara, Turkey.
  • Department of Nursing, Yüsek İhtisas Cardiovascular Hospital, University of Health Sciences, Ankara Bilkent City Hospital, Ankara, Türkiye.
  • Department of Intensive Care Unit, University of Health Sciences, Ankara Bilkent City Hospital, Ankara, Türkiye.

ORCID-Profile: Berrin Pazar, Hafize Savas

Zitieren

APA

Pazar, B., Savas, H., Turgut, S., & Dal, H. C. (2025). Development of the compliance with mechanical ventilator scale in: A validity and reliability study. Nursing in Critical Care. https://doi.org/10.1111/nicc.13191

Vancouver

Pazar B, Savas H, Turgut S, Dal HC. Development of the compliance with mechanical ventilator scale in: A validity and reliability study. Nursing in Critical Care. 2025. doi:10.1111/nicc.13191

BibTeX
@article{Pazar2025,
  author = {Pazar, Berrin and Savas, Hafize and Turgut, Sadık and Dal, Hayriye Cankar},
  title = {Development of the compliance with mechanical ventilator scale in: A validity and reliability study},
  journal = {Nursing in Critical Care},
  year = {2025},
  doi = {10.1111/nicc.13191}
}
Kostenlos starten →