EUVIMEDEUVIMED entdecken
Crossref

Incidence, characteristics and risk factors of endotracheal tube‐related pressure injuries in intensive care units

Inzidenz, Merkmale und Risikofaktoren von druckbedingten Verletzungen durch Endotrachealtuben auf Intensivstationen

Cansu Cambaz iD, Zeliha Ozdemir Koken iD, Mehmet Murat Sayin iD

Nursing in Critical Care · 2024-11 · 29 (6) · 1610-1618

DOI: 10.1111/nicc.13164 ↗

Auf einen Blick

In einer prospektiven Studie mit 146 intubierten Patient:innen entwickelten 80,14 % eine ETT-assoziierte Druckverletzung. Hoher Body-Mass-Index war damit assoziiert.

Fragestellung

Welche Inzidenz, Merkmale und Risikofaktoren haben endotrachealtubusbedingte Druckverletzungen bei ICU-Patient:innen?

Methode

Prospektive deskriptive Studie bei 146 endotracheal intubierten Patient:innen; Erhebung mit Informationsbogen, ETT-Assessment, Braden- und Ernährungs-Tool.

Ergebnisse

80,14 % der Patient:innen entwickelten ETT-assoziierte Druckverletzungen. 56,41 % traten an Tag 3 oder 4 auf. Hoher BMI war assoziiert: OR 1,15 (95 %-KI 1,05–1,26; p = .003).

Schlussfolgerung der Autor:innen

Die Inzidenz von ETT-assoziierten Druckverletzungen war in den internistischen, chirurgischen und anästhesiologischen ICU hoch. Hoher BMI war damit assoziiert.

Kernaussagen

  • 80,14 % der Patient:innen entwickelten eine ETT-assoziierte Druckverletzung
  • 56,41 % traten an Tag 3 oder 4 auf
  • Hoher BMI war assoziiert: OR 1,15 (95 %-KI 1,05–1,26)

Deutsche Zusammenfassung: KI-gestützt aus dem Original-Abstract erstellt; alle Zahlen wurden automatisch mit dem Original abgeglichen. Maßgeblich ist der Original-Abstract.

Kurz gefasst

Fachartikel in der Zeitschrift Nursing in Critical Care, online erschienen am 29.09.2024. Verfasst von Cansu Cambaz und 2 weiteren Autor:innen. Beteiligte Einrichtung: Surgical Nursing Department, Faculty of Nursing, Hacettepe University, Ankara, Turkey. Hauptthemen laut MEDLINE: Intubation, Intratracheal, Pressure Ulcer, Intensive Care Units. Die Arbeit wurde bisher 14-mal zitiert (Crossref) und nennt 31 Literaturangaben.

Auf einen BlickAbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Medical devices commonly used for the treatment and care of critically ill patients can cause pressure injuries in intensive care units (ICUs). The endotracheal tube (ETT) is one of the most common medical devices to cause pressure injuries.

Aim

This study investigated the incidence of, characteristics of and risk factors for ETT‐related pressure injuries for ICU patients. Study Design This study adopted a prospective descriptive research design. The sample consisted of 146 endotracheally intubated patients. Data were collected using a patient information form, an Endotracheal Tube‐Related Pressure Injuries Assessment Form, the Braden Risk Assessment Tool and the Nutritional Assessment Test.

Results

The study revealed that 80.14% of the patients developed ETT‐related pressure injuries. Over half of the ETT‐related pressure injuries appeared on Day 3 or 4 (56.41%). High body mass index was found to be associated with the development of ETT‐related pressure injuries (OR: 1.15, 95% CI: 1.05–1.26, p = .003). None of the other variables were statistically significant in the development of pressure injuries.

Conclusions

The incidence of ETT‐related pressure injuries was quite high in the internal, surgical and anaesthesia ICUs. High body mass index was associated with the development of ETT‐related pressure injuries. Intensive care nurses should implement interventions to prevent ETT‐related pressure injuries in critically ill patients receiving mechanical ventilation support. Relevance to Clinical Practice ETT‐related pressure injuries are common in ICU patients. High body mass index was associated with the development of ETT‐related pressure injuries in critically ill patients. The skin and mucosa should be assessed for the development of ETT‐related pressure injuries during the daily assessment of the patients receiving mechanical ventilation support. The ETT should be repositioned regularly, and the most suitable ETT fixation method should be used.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Intubation, IntratrachealPressure UlcerIntensive Care UnitsHumansMaleFemaleProspective StudiesIncidenceRisk FactorsMiddle AgedRisk AssessmentAdultBody Mass IndexAgedCritical Illness

Stichwörter der Autor:innen

endotracheal tubeintensive caremedical devicenursepressure injury

Autor:innen und Institutionen

  • Surgical Nursing Department, Faculty of Nursing, Hacettepe University, Ankara, Turkey.
  • Anesthesiology and Reanimation Department, University of Health Sciences, Etlik City Hospital, Ankara, Turkey.

ORCID-Profile: Cansu Cambaz, Zeliha Ozdemir Koken, Mehmet Murat Sayin

Zitieren

APA

Cambaz, C., Ozdemir Koken, Z., & Sayin, M. M. (2024). Incidence, characteristics and risk factors of endotracheal tube‐related pressure injuries in intensive care units. Nursing in Critical Care, 29(6), 1610-1618. https://doi.org/10.1111/nicc.13164

Vancouver

Cambaz C, Ozdemir Koken Z, Sayin MM. Incidence, characteristics and risk factors of endotracheal tube‐related pressure injuries in intensive care units. Nursing in Critical Care. 2024;29(6):1610-1618. doi:10.1111/nicc.13164

BibTeX
@article{Cambaz2024,
  author = {Cambaz, Cansu and Ozdemir Koken, Zeliha and Sayin, Mehmet Murat},
  title = {Incidence, characteristics and risk factors of endotracheal tube‐related pressure injuries in intensive care units},
  journal = {Nursing in Critical Care},
  year = {2024},
  volume = {29},
  number = {6},
  pages = {1610--1618},
  doi = {10.1111/nicc.13164}
}
Kostenlos starten →