EUVIMEDEUVIMED entdecken
Validierungsstudie

Development of the Critically Ill Patient Eye Assessment Scale: A study of validity and reliability

Burcu Bayrak Kahraman iD, Aysun Acun, Elif Sözeri Öztürk, Kamile Kirca iD

Nursing in Critical Care · 2025

DOI: 10.1111/nicc.13128 ↗

Kurz gefasst

Validierungsstudie in der Zeitschrift Nursing in Critical Care, 2025. Verfasst von Burcu Bayrak Kahraman und 3 weiteren Autor:innen. Beteiligte Einrichtung: Nursing Department, Health Sciences Faculty, Bilecik Şeyh Edebali University, Bilecik, Türkiye. Hauptthemen laut MEDLINE: Critical Illness, Eye Diseases, Psychometrics. Die Arbeit nennt 33 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Eye care and assessment of the eye are critical for intensive care patients to prevent ocular complications like dry eye and corneal abrasion. However, there is no measurement tool developed for intensive care patients that examines the risks of ocular complications.

Aim

This study aims to develop a valid and reliable tool, the Critically Ill Patient Eye Assessment Scale (CIPEAS), for assessing the risk of ocular complications and determining the frequency of eye care. Study design This study is an instrument development study. This methodological study was conducted with 151 intensive care patients in Turkey between March 2022 and March 2023. Data were collected with the Patient Information Form and the CIPEAS. The data were evaluated using SPSS 23 statistical software. AMOS 21 was used to verify the structure obtained with CFA. Exploration and confirmatory factor analyses were performed to determine the scale's factorial structure.

Results

As a result of exploratory factor analysis, a six‐item scale consisting of a single dimension was obtained, explaining 59.993% of the total variance. The fit indices of the scale were found to be χ 2 /SD = 2.653, GFI = 0.954, RMSEA = 0.075, NFI = 0.949 and CFI = 0.967. Cronbach's alpha of the scale was found to be 0.862.

Conclusion

The CIPEAS was found to be a valid and reliable assessment tool. Relevance to Clinical Practice The Critically Ill Patient Eye Assessment Scale is a valid and reliable tool for Turkish society for assessing the risk of ocular complications. It is recommended for various national and international studies with different patients in intensive care units.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Critical IllnessEye DiseasesPsychometricsHumansMaleFemaleReproducibility of ResultsTurkeyMiddle AgedSurveys and QuestionnairesAdultIntensive Care UnitsAgedFactor Analysis, Statistical

Stichwörter der Autor:innen

eye careintensive care patientsnursing carereliabilityvalidity

Autor:innen und Institutionen

  • Nursing Department, Health Sciences Faculty, Bilecik Şeyh Edebali University, Bilecik, Türkiye.
  • Faculty of Nursing, Gazi University, Ankara, Türkiye.
  • Nursing Department, Health Sciences Faculty, Kırıkkale University, Kırıkkale, Türkiye.

ORCID-Profile: Burcu Bayrak Kahraman, Kamile Kirca

Zitieren

APA

Bayrak Kahraman, B., Acun, A., Sözeri Öztürk, E., & Kirca, K. (2025). Development of the Critically Ill Patient Eye Assessment Scale: A study of validity and reliability. Nursing in Critical Care. https://doi.org/10.1111/nicc.13128

Vancouver

Bayrak Kahraman B, Acun A, Sözeri Öztürk E, Kirca K. Development of the Critically Ill Patient Eye Assessment Scale: A study of validity and reliability. Nursing in Critical Care. 2025. doi:10.1111/nicc.13128

BibTeX
@article{BayrakKahraman2025,
  author = {Bayrak Kahraman, Burcu and Acun, Aysun and Sözeri Öztürk, Elif and Kirca, Kamile},
  title = {Development of the Critically Ill Patient Eye Assessment Scale: A study of validity and reliability},
  journal = {Nursing in Critical Care},
  year = {2025},
  doi = {10.1111/nicc.13128}
}
Infokarte | EUVIMED

Artikeldaten derzeit nicht verfügbar.

Recherche