Optimal flow volume measurements in forearm versus arm arteriovenous fistulas

Erwin Yii iD, Limi Lee, Kevan Polkinghorne, Stephen Thwaites, Alan Saunder, Ming Kon Yii

Nephrology · 2023

DOI: 10.1111/nep.14142 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Nephrology, 2023. Verfasst von Erwin Yii und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Surgery, School of Clinical Sciences at Monash Health, Monash University, Clayton, Victoria, Australia. Hauptthemen laut MEDLINE: Arteriovenous Shunt, Surgical, Thrombosis, Arteriovenous Fistula. Die Arbeit wurde bisher 7-mal zitiert (Crossref) und nennt 22 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objectives

Successful haemodialysis is dependent on optimal arteriovenous (AV) access flow. Although 600 ml/min is frequently quoted as the critical level for functional flow volume (Qa) according to the National Kidney Foundation guideline, this may not be applicable for the different configurations of AV fistulas (AVF) or AV grafts (AVG). This study evaluates ultrasound derived Qa measurement in the inflow brachial artery to autologous AVF in the forearm radiocephalic and arm brachiocephalic/basilic configurations in relation to significant flow related AV dysfunction.

Methods

Five hundred and eleven duplex ultrasound (DUS) scans were analysed in 193 patients. The end points were therapeutic intervention and/or thrombosis of AVF versus no complication within 3 months of the scan. Receiver operating characteristic (ROC) curves were used to determine the optimal threshold Qa of the brachial artery supplying the AVF.

Results

Of the 511 scans, 155 scans were assigned to the intervention group, that is, AVF requiring intervention or thrombosing within 3 months of the DUS. Using ROC curve analysis, the area under the curve (AUC) for all AVF is 0.90 (CI: 0.88–0.93) with an optimal threshold Qa of 686 ml/min. In forearm AVF, the threshold Qa is 589 ml/min while in arm AVF the threshold Qa is 877 ml/min. Forearm Qa is statistically different from arm Qa.

Conclusion

Forearm AVF Qa threshold at 589 ml/min is distinct from arm AVF Qa at 877 ml/min and these are predictive of the need for impending intervention or thrombosis due to flow‐limiting stenosis.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Arteriovenous Shunt, SurgicalThrombosisArteriovenous FistulaHumansForearmArmVascular PatencyBlood Flow VelocityRenal Dialysis

Stichwörter der Autor:innen

arteriovenous fistulablood flow measurementbrachial diameterdialysis vascular accesstime averaged mean velocity ultrasonography

Autor:innen und Institutionen

  • Department of Surgery, School of Clinical Sciences at Monash Health, Monash University, Clayton, Victoria, Australia.
  • Vascular Surgery Unit at Eastern Health, Box Hill Hospital, Box Hill, Victoria, Australia.
  • Vascular and Transplant Surgery Unit at Monash Health, Monash Medical Centre, Clayton, Victoria, Australia.
  • Department of Nephrology at Monash Health, Monash Medical Centre, Clayton, Victoria, Australia.

ORCID-Profile: Erwin Yii

Zitieren

APA

Yii, E., Lee, L., Polkinghorne, K., Thwaites, S., Saunder, A., & Yii, M. K. (2023). Optimal flow volume measurements in forearm versus arm arteriovenous fistulas. Nephrology. https://doi.org/10.1111/nep.14142

Vancouver

Yii E, Lee L, Polkinghorne K, Thwaites S, Saunder A, Yii MK. Optimal flow volume measurements in forearm versus arm arteriovenous fistulas. Nephrology. 2023. doi:10.1111/nep.14142

BibTeX
@article{Yii2023,
  author = {Yii, Erwin and Lee, Limi and Polkinghorne, Kevan and Thwaites, Stephen and Saunder, Alan and Yii, Ming Kon},
  title = {Optimal flow volume measurements in forearm versus arm arteriovenous fistulas},
  journal = {Nephrology},
  year = {2023},
  doi = {10.1111/nep.14142}
}
Kostenlos starten →