Transesophageal Echocardiography-Related Complications During Mitral Valve Repair in Dogs
Journal of Veterinary Internal Medicine · 2025
DOI: 10.1111/jvim.70037 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Veterinary Internal Medicine, 2025. Verfasst von Kentaro Kurogochi und 5 weiteren Autor:innen. Beteiligte Einrichtung: JASMINE Veterinary Cardiovascular Medical Center, Yokohama, Kanagawa, Japan. Hauptthemen laut MEDLINE: Echocardiography, Transesophageal, Dog Diseases, Mitral Valve, Mitral Valve Insufficiency. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 52 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).
Abstract (Originalsprache)
Background
Transesophageal echocardiography (TEE) is an indispensable modality in cardiac surgery; however, the complications associated with its use in veterinary clinical settings remain unclear. Hypothesis/Objectives To investigate the complications associated with TEE probe manipulation during mitral valve repair in dogs and identify the risk factors for new mucosal injuries. Animals This prospective study evaluated 60 client-owned dogs that underwent TEE to support mitral valve repair.
Methods
Esophageal endoscopy was performed twice—once after anesthesia induction and once before extubation—to assess esophageal mucosal injuries during the procedure. The type of injury was classified as ‘complex’ (intramural hematoma and mucosal laceration), ‘minor’ (petechiae and ecchymosis), or ‘minute’ (visible only on narrowband imaging) lesions. During the surgery, TEE was performed three times. Hemodynamics were evaluated before the initial TEE insertion and immediately after it was removed.
Results
Of the 60 dogs, newly detected mucosal lesions were observed in 20 dogs and classified as ‘minor’ in four and ‘minute’ in 16 dogs. These ‘minute’ lesions were not visible with conventional endoscopy, and no ‘complex’ lesions were identified. No significant factors were associated with the presence of mucosal lesions. After TEE insertion, systolic blood pressure decreased from 95 ± 13 mmHg to 92 ± 11 mmHg (p = 0.008), and heart rate decreased from 128 ± 25 bpm to 123 ± 24 bpm (p < 0.001). Conclusions and Clinical Importance Intraoperative TEE results in a low incidence of esophageal mucosal injuries. Hemodynamic changes could occur during TEE manipulation, underscoring the need for close monitoring.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- JASMINE Veterinary Cardiovascular Medical Center, Yokohama, Kanagawa, Japan.
- Department of Clinical Sciences, North Carolina State University, College of Veterinary Medicine, Raleigh, North Carolina, USA.
ORCID-Profile: Kentaro Kurogochi
Zitieren
APA
Kurogochi, K., Takahashi, A., Nii, Y., Suzuki, T., Mizuno, M., & Uechi, M. (2025). Transesophageal Echocardiography-Related Complications During Mitral Valve Repair in Dogs. Journal of Veterinary Internal Medicine. https://doi.org/10.1111/jvim.70037
Vancouver
Kurogochi K, Takahashi A, Nii Y, Suzuki T, Mizuno M, Uechi M. Transesophageal Echocardiography-Related Complications During Mitral Valve Repair in Dogs. Journal of Veterinary Internal Medicine. 2025. doi:10.1111/jvim.70037
BibTeX
@article{Kurogochi2025,
author = {Kurogochi, Kentaro and Takahashi, Arane and Nii, Yasuyuki and Suzuki, Tomoya and Mizuno, Masashi and Uechi, Masami},
title = {Transesophageal Echocardiography-Related Complications During Mitral Valve Repair in Dogs},
journal = {Journal of Veterinary Internal Medicine},
year = {2025},
doi = {10.1111/jvim.70037}
}
EUVIMED