EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC-ND 4.0

Correlation between semiautomated magnetic resonance imaging volumetry of the cingulate gyrus and interictal epileptiform discharge lateralization in dogs with idiopathic epilepsy

Aleksandra Banasik iD, Marcin Wrzosek iD, Paulina Drobot iD, Karolina Owsińska-Schmidt iD, Laura Brewińska iD, Anna Zimny, Przemysław Podgórski

Journal of Veterinary Internal Medicine · 2024

DOI: 10.1111/jvim.17178 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Veterinary Internal Medicine, 2024. Verfasst von Aleksandra Banasik und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Internal Medicine and Clinic of Diseases of Horses, Dogs and Cats, Wrocław University of Environmental and Life Sciences, Wrocław, Pola…. Hauptthemen laut MEDLINE: Dog Diseases, Magnetic Resonance Imaging, Gyrus Cinguli, Epilepsy. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 59 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0). Gefördert von: Wrocław University of Environmental and Life Sciences (Poland), The APC/BPC is financed by Wrocław University of Environmental and Life Sciences.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Brain imaging suggests the involvement of the limbic system, particularly the cingulate gyrus (GC), in dogs with idiopathic epilepsy (IE). Hypothesis A correlation exists between the side of interictal epileptiform discharges (IEDs) and the volume of the ipsilateral GC (GCe) in dogs with IE. Animals Dogs admitted to the neurological consultation (32 with epileptic seizures and 13 control) were included.

Methods

This retrospective, blinded study followed the International Veterinary Epilepsy Task Force recommendations for diagnosing IE at the Tier III confidence level. The IE group included 18 and 14 dogs with IEDs in the left and right hemispheres, respectively (median age: 36 months, median weight: 19.5 kg), whereas the control group included 13 dogs (median age: 32 months, median weight: 20 kg). Whole-brain and GC-volumetric assessments were performed by a semiautomated method.

Results

In the control group, the volume of the GC was: left, from 743.63 to 1001.61 mm3, right, from 789.35 to 1015.86 mm3. In the study group, the volume of the GC was: left, from 720.88 to 1054.9 mm3 and right, from 566.29 to 987.77 mm3. In dogs with IE, GCe volume was significantly lower than the mean volume of the GC in the control group relative to total intracranial volume (TIV; P = .00044). Conclusions and Clinical Importance Alterations in the volume of the GC provide insights into structural changes during IE. The use of semiautomatic volumetry provides an advantage by reducing the potential for human error.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Dog DiseasesMagnetic Resonance ImagingGyrus CinguliEpilepsyAnimalsDogsRetrospective StudiesMaleFemaleCase-Control Studies

Stichwörter der Autor:innen

brain imaginglimbic systemretrospective clinical studyveterinary medicine

Autor:innen und Institutionen

  • Department of Internal Medicine and Clinic of Diseases of Horses, Dogs and Cats, Wrocław University of Environmental and Life Sciences, Wrocław, Poland.
  • NeuroTeam Specialist Veterinary Clinic, Wrocław, Poland.
  • Department of General and Interventional Radiology and Neuroradiology, Wrocław Medical University, Wrocław, Poland.

ORCID-Profile: Aleksandra Banasik, Marcin Wrzosek, Paulina Drobot, Karolina Owsińska-Schmidt, Laura Brewińska

Förderung

  • Wrocław University of Environmental and Life Sciences (Poland)
  • The APC/BPC is financed by Wrocław University of Environmental and Life Sciences

Zitieren

APA

Banasik, A., Wrzosek, M., Drobot, P., Owsińska-Schmidt, K., Brewińska, L., Zimny, A., & Podgórski, P. (2024). Correlation between semiautomated magnetic resonance imaging volumetry of the cingulate gyrus and interictal epileptiform discharge lateralization in dogs with idiopathic epilepsy. Journal of Veterinary Internal Medicine. https://doi.org/10.1111/jvim.17178

Vancouver

Banasik A, Wrzosek M, Drobot P, Owsińska-Schmidt K, Brewińska L, Zimny A, et al. Correlation between semiautomated magnetic resonance imaging volumetry of the cingulate gyrus and interictal epileptiform discharge lateralization in dogs with idiopathic epilepsy. Journal of Veterinary Internal Medicine. 2024. doi:10.1111/jvim.17178

BibTeX
@article{Banasik2024,
  author = {Banasik, Aleksandra and Wrzosek, Marcin and Drobot, Paulina and Owsińska-Schmidt, Karolina and Brewińska, Laura and Zimny, Anna and Podgórski, Przemysław},
  title = {Correlation between semiautomated magnetic resonance imaging volumetry of the cingulate gyrus and interictal epileptiform discharge lateralization in dogs with idiopathic epilepsy},
  journal = {Journal of Veterinary Internal Medicine},
  year = {2024},
  doi = {10.1111/jvim.17178}
}
Kostenlos starten →