EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC-ND 4.0

Tilt Table Testing in Paediatric Orthostatic Intolerance: Is 10 Min Long Enough?

Wonshik Choi iD, Sin Weon Yun iD

Journal of Paediatrics and Child Health · 2026-11 · 62 (11) · 2208-2216

DOI: 10.1111/jpc.70560 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Paediatrics and Child Health, online erschienen am 09.09.2026. Verfasst von Wonshik Choi und 1 weiteren Autor:innen. Beteiligte Einrichtung: Department of Pediatrics, Chung-Ang University Hospital, Seoul, Korea. Hauptthemen laut MEDLINE: Tilt-Table Test, Orthostatic Intolerance. Die Arbeit nennt 20 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Aim

Recent cardiovascular literature suggests that orthostatic testing protocols should be tailored according to diagnostic purpose, distinguishing syncope evaluation from assessment of autonomic dysfunction in chronic orthostatic intolerance (COI). In adults, autonomic testing is commonly interpreted within a 10‐min observation period, such as the active stand test. However, no specific time‐based protocol has been clearly established for paediatric groups. This study examined whether a 10‐min head‐up tilt table test (HUTT) provides sufficient diagnostic yield in paediatric COI.

Methods

We retrospectively screened 410 paediatric patients who underwent a 30‐min, non‐pharmacological HUTT between 2008 and 2024, of whom 97 were included in the final cohort after excluding syncope‐only presentations and other underlying diseases. Positive responses were classified as orthostatic hypotension, postural orthostatic tachycardia syndrome or vasovagal syncope. Cumulative positivity rates were compared across 10‐, 20‐ and 30‐min intervals, and time to first positive response was analysed by COI subtype.

Results

Cumulative positivity increased with longer testing, from 25.8% at 10 min to 44.3% at 20 min and 55.6% at 30 min. Median time to positivity was 14 min overall, occurring later in orthostatic hypotension and vasovagal syncope than in postural orthostatic tachycardia syndrome. A substantial proportion of positive responses occurred beyond the first 10 min.

Conclusion

In paediatric COI, a 10‐min HUTT may be insufficient to detect diagnostically relevant haemodynamic responses. These findings suggest that future studies of paediatric COI may need to consider orthostatic testing protocols with a minimum duration of 20 min to optimise diagnostic yield.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Tilt-Table TestOrthostatic IntoleranceHumansRetrospective StudiesFemaleMaleChildTime FactorsPostural Orthostatic Tachycardia SyndromeChild, PreschoolAdolescentHypotension, OrthostaticSyncope, Vasovagal

Stichwörter der Autor:innen

autonomic disorderorthostatic hypotensionorthostatic intolerancepostural orthostatic tachycardia syndrometilt table test

Autor:innen und Institutionen

  • Department of Pediatrics, Chung-Ang University Hospital, Seoul, Korea.

ORCID-Profile: Wonshik Choi, Sin Weon Yun

Zitieren

APA

Choi, W., & Yun, S. W. (2026). Tilt Table Testing in Paediatric Orthostatic Intolerance: Is 10 Min Long Enough?. Journal of Paediatrics and Child Health, 62(11), 2208-2216. https://doi.org/10.1111/jpc.70560

Vancouver

Choi W, Yun SW. Tilt Table Testing in Paediatric Orthostatic Intolerance: Is 10 Min Long Enough?. Journal of Paediatrics and Child Health. 2026;62(11):2208-2216. doi:10.1111/jpc.70560

BibTeX
@article{Choi2026,
  author = {Choi, Wonshik and Yun, Sin Weon},
  title = {Tilt Table Testing in Paediatric Orthostatic Intolerance: Is 10 Min Long Enough?},
  journal = {Journal of Paediatrics and Child Health},
  year = {2026},
  volume = {62},
  number = {11},
  pages = {2208--2216},
  doi = {10.1111/jpc.70560}
}