EUVIMEDEUVIMED entdecken
Crossref

Accuracy of an innovative extraction socket–supported guide for immediate anterior implantation: An in vitro study

Jianye Song, Zuge Yang, Wenhao Yang iD, Zhonghua Cao, Zhenxin Huang, Fangke Jiang, Weiwei Guo, Kun Wang iD

Journal of Prosthodontics · 04.11.2026

DOI: 10.1111/jopr.70271 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Prosthodontics, online erschienen am 04.11.2026. Verfasst von Jianye Song und 7 weiteren Autor:innen. Beteiligte Einrichtung: Department of Stomatology, Xinqiao Hospital, Army Medical University, Chongqing, P. R. China. Die Arbeit nennt 29 Literaturangaben. Gefördert von: The Open Project of Chongqing Engineering Research Center of Organ Intelligent Bio-Manufacturing.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

This study aimed to evaluate the accuracy of a root‐shaped extraction socket–supported guide (ESSG) for anterior single‐tooth immediate implant placement. Materials and Methods After the central incisors were digitally removed from cone beam computed tomography (CBCT) images obtained from patients, 3D‐printed models were created to simulate labial (Type I), central (Type II), and palatal root‐position deviation (Type III) in the sagittal plane. Resin models of each type were divided into high‐elastic‐modulus (HE) and normal‐elastic‐modulus (NE) subgroups. In total, 120 implants were immediately placed using ESSGs (test group) or tooth‐supported surgical guides (TSSGs; control group). The angular and positional deviations were assessed by comparing post‐placement CBCT scans with the corresponding virtual implant plans.

Results

In Type I and III resin models, angular deviations were significantly smaller in the test group ( p < 0.05) than in the control group, with values of 1.34° ± 0.75° versus 4.28° ± 0.71° (Type I, HE), 0.83° ± 0.76° versus 2.74° ± 1.05° (Type I, NE), 1.18° ± 0.82° versus 3.57° ± 1.40° (Type III, HE), and 1.17° ± 0.79° versus 3.41° ± 1.16° (Type III, NE), respectively. Positional deviations in most Type I and III resin models were likewise significantly lower in the test group than in the control group. Notably, ESSGs maintained high accuracy in HE resin models of Types I and III.

Conclusions

ESSGs demonstrated greater precision than TSSGs in resin models simulating labial and palatal deviations of socket morphology. Nevertheless, clinical studies are still needed to evaluate their applicability in patients.

Schlagwörter

Stichwörter der Autor:innen

extraction socket–supported guideimmediate implant placementprecisionstatic guidetooth‐supported

Autor:innen und Institutionen

  • Department of Stomatology, Xinqiao Hospital, Army Medical University, Chongqing, P. R. China.
  • Department of Stomatology, Southern Theater Air Force Hospital, Guangzhou, Guangdong, P. R. China.
  • State Key Laboratory of Oral & Maxillofacial Reconstruction and Regeneration, National Clinical Research Center for Oral Diseases, Shaanxi Clinical Research Center for Oral Diseases, Department of Oral and Maxillofacial…

ORCID-Profile: Wenhao Yang, Kun Wang

Förderung

  • The Open Project of Chongqing Engineering Research Center of Organ Intelligent Bio-Manufacturing

Zitieren

APA

Song, J., Yang, Z., Yang, W., Cao, Z., Huang, Z., Jiang, F., Guo, W., & Wang, K. (2026). Accuracy of an innovative extraction socket–supported guide for immediate anterior implantation: An in vitro study. Journal of Prosthodontics. https://doi.org/10.1111/jopr.70271

Vancouver

Song J, Yang Z, Yang W, Cao Z, Huang Z, Jiang F, et al. Accuracy of an innovative extraction socket–supported guide for immediate anterior implantation: An in vitro study. Journal of Prosthodontics. 2026. doi:10.1111/jopr.70271

BibTeX
@article{Song2026,
  author = {Song, Jianye and Yang, Zuge and Yang, Wenhao and Cao, Zhonghua and Huang, Zhenxin and Jiang, Fangke and Guo, Weiwei and Wang, Kun},
  title = {Accuracy of an innovative extraction socket–supported guide for immediate anterior implantation: An in vitro study},
  journal = {Journal of Prosthodontics},
  year = {2026},
  doi = {10.1111/jopr.70271}
}
Kostenlos starten →