EUVIMEDEUVIMED entdecken
ÜbersichtsarbeitSystematische Übersicht

Artificial intelligence in radiographic quantification and severity assessment of peri‐implant marginal bone loss: A systematic review

Künstliche Intelligenz in der radiografischen Quantifizierung und Schweregradbeurteilung von periimplantärem marginalem Knochenverlust: eine systematische Übersicht

Hooman Khanzadeh iD, Sanaz Azizigermi, Aida Mokhlesi iD, Rasoul Gheisari iD, Gülce Çakmak iD, Pedro Molinero-Mourelle iD, Andrea Roccuzzo iD, Seyed Ali Mosaddad iD

Journal of Prosthodontics · 22.09.2026

DOI: 10.1111/jopr.70245 ↗

Auf einen Blick

17 Studien untersuchten KI-Modelle zur radiografischen Beurteilung von periimplantärem marginalem Knochenverlust. Die Leistung war aufgabenspezifisch; für die Routineversorgung wird die klinische Nutzung derzeit nicht empfohlen.

Fragestellung

Wie gut eignen sich KI-basierte radiografische Modelle zur Messung, Lokalisation/Detektion, Segmentierung/Keypoints, Klassifikation sowie Schweregrad- oder Morphologiebeurteilung von periimplantärem marginalem Knochenverlust?

Methode

Systematische Übersicht; Suche in PubMed/MEDLINE, Scopus, Web of Science, Embase, Cochrane Library, Google Scholar und Referenzlisten bis 11. August 2026; Bewertung mit QUADAS-3 und PROBAST.

Ergebnisse

17 Studien eingeschlossen. Detektion: Precision 0,977, Recall 0,992, F1 0,984, mIoU 0,916. Segmentierung: Dice 0,986, IoU 0,974. Klassifikation: Precision 0,777. Sensitivität etwa 66 % bis 96 %.

Einschränkungen

Kein Studienbericht zur vollständigen vorab definierten absoluten MBL-Messübereinstimmung; keine klar nachvollziehbare unabhängige multizentrische externe Validierung.

Schlussfolgerung der Autor:innen

Die Leistung war aufgabenspezifisch und beruhte häufig auf retrospektiv ausgewählten, angereicherten, intern aufgeteilten oder augmentierten Datensätzen. Für die Routine ist die klinische Anwendung derzeit nicht zu empfehlen.

Kernaussagen

  • Detektion von Implantat-/Gewebegrenzen mit hoher Präzision und Trefferquote
  • Segmentierungsergebnisse ebenfalls hoch, Klassifikationsleistung geringer
  • Keine vollständige absolute MBL-Messübereinstimmung berichtet

Deutsche Zusammenfassung: KI-gestützt aus dem Original-Abstract erstellt; alle Zahlen wurden automatisch mit dem Original abgeglichen. Maßgeblich ist der Original-Abstract.

Kurz gefasst

Übersichtsarbeit in der Zeitschrift Journal of Prosthodontics, online erschienen am 22.09.2026. Verfasst von Hooman Khanzadeh und 7 weiteren Autor:innen. Beteiligte Einrichtung: Research Institute for Dental Sciences, Shahid Beheshti University of Medical Sciences, Tehran, Iran. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 65 Literaturangaben.

Auf einen BlickAbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

To critically assess artificial intelligence (AI)‐based radiographic models for quantitative measurement, localization/detection, segmentation/keypoints, diagnostic classification, and severity or morphology assessment of peri‐implant marginal bone loss (MBL) and peri‐implantitis‐related bone defects.

Methods

PubMed/MEDLINE, Scopus, Web of Science, Embase, the Cochrane Library, Google Scholar, and reference lists were searched from inception through August 11, 2026. Eligible original studies evaluated AI‐based radiographic assessment of existing dental implants. Quality Assessment of Diagnostic Accuracy Studies‐3 (QUADAS‐3) was applied at the prespecified estimate level for diagnostic/image‐analysis studies and PROBAST for the prediction‐model study.

Results

A total of 1485 records were identified, and 17 studies were included. Fourteen reported localization/detection outcomes, six segmentation/keypoint outcomes, 10 severity/morphology outcomes, 12 diagnostic/classification outcomes, and six direct AI–clinician comparisons; categories overlapped. Implant/peri‐implant tissue detection reached precision of 0.977, recall of 0.992, F1 score of 0.984, and mean intersection over union (IoU) of 0.916. Implant segmentation achieved a Dice of 0.986 and IoU of 0.974, whereas downstream peri‐implantitis classification precision was 0.777. Sensitivity across diagnostic/prediction tasks ranged from approximately 66% to 96%. No study reported the complete prespecified absolute MBL measurement‐agreement outcome set. Six studies used explicitly independent multi‐rater reference standards with consensus and/or reported reliability, and none underwent clearly traceable independent multicenter external validation.

Conclusions

Reported performance is task‐specific and is frequently derived from retrospectively selected, enriched, internally split, or augmented datasets. Current models may support research and carefully supervised radiographic image‐analysis tasks, but none can be recommended for routine clinical use until independent multicenter external validation and prospective studies demonstrate clinically acceptable absolute measurement error and patient‐relevant benefit.

Schlagwörter

Stichwörter der Autor:innen

alveolar bone lossartificial intelligencecomputer‐assistedcone‐beam computed tomographydeep learningdentaldental implantsdiagnostic imagingimage interpretationmachine learningperi‐implantitisradiographysystematic reviews as topic

Autor:innen und Institutionen

  • Research Institute for Dental Sciences, Shahid Beheshti University of Medical Sciences, Tehran, Iran.
  • Faculty of Dentistry, Department of Prosthodontics, University of Toronto, Toronto, Ontario, Canada.
  • Research Committee, Qazvin University of Medical Sciences, Qazvin, Iran.
  • Oral and Maxillofacial Surgeon, Private Practice, Shiraz, Iran.
  • Department of Prosthodontics, Geriatric Dentistry and Craniomandibular Disorders, Charité-Universitätsmedizin, Berlin, Germany.
  • Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, Bern, Switzerland.

ORCID-Profile: Hooman Khanzadeh, Aida Mokhlesi, Rasoul Gheisari, Gülce Çakmak, Pedro Molinero-Mourelle, Andrea Roccuzzo, Seyed Ali Mosaddad

Zitieren

APA

Khanzadeh, H., Azizigermi, S., Mokhlesi, A., Gheisari, R., Çakmak, G., Molinero-Mourelle, P., Roccuzzo, A., & Mosaddad, S. A. (2026). Artificial intelligence in radiographic quantification and severity assessment of peri‐implant marginal bone loss: A systematic review. Journal of Prosthodontics. https://doi.org/10.1111/jopr.70245

Vancouver

Khanzadeh H, Azizigermi S, Mokhlesi A, Gheisari R, Çakmak G, Molinero-Mourelle P, et al. Artificial intelligence in radiographic quantification and severity assessment of peri‐implant marginal bone loss: A systematic review. Journal of Prosthodontics. 2026. doi:10.1111/jopr.70245

BibTeX
@article{Khanzadeh2026,
  author = {Khanzadeh, Hooman and Azizigermi, Sanaz and Mokhlesi, Aida and Gheisari, Rasoul and Çakmak, Gülce and Molinero-Mourelle, Pedro and Roccuzzo, Andrea and Mosaddad, Seyed Ali},
  title = {Artificial intelligence in radiographic quantification and severity assessment of peri‐implant marginal bone loss: A systematic review},
  journal = {Journal of Prosthodontics},
  year = {2026},
  doi = {10.1111/jopr.70245}
}
Kostenlos starten →