EUVIMEDEUVIMED entdecken
StudienprotokollOpen Access · CC BY 4.0

Effects of scanner type and prosthesis design–luting protocol combinations on the passive fit of interim implant‐supported complete‐arch fixed dental prostheses

Daizo Ishiguro iD, Mohamed Sherif Omar iD, Wei-Shao Lin iD, Toshiki Nagai iD

Journal of Prosthodontics · 21.08.2026

DOI: 10.1111/jopr.70218 ↗

Kurz gefasst

Studienprotokoll in der Zeitschrift Journal of Prosthodontics, online erschienen am 21.08.2026. Verfasst von Daizo Ishiguro und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Prosthodontics, Indiana University School of Dentistry, Indianapolis, Indiana, USA. Die Arbeit nennt 45 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

To evaluate the effects of scanner type and prosthesis design–luting protocol combinations on the passive fit of interim implant‐supported complete‐arch fixed dental prostheses (ISCFDPs) fabricated using a non‐calibrated splinting grammetry system (OptiSplint). The null hypothesis was that scanner type and prosthesis design–luting protocol combinations would not affect the passive fit of interim ISCFDPs. Materials and Methods This in vitro 2 × 3 factorial study utilized a maxillary edentulous FP‐3 master cast with 4 multiunit abutment (MUA) analogs. Extraoral scans of the OptiSplint assembly were obtained using either an intraoral scanner (IOS‐OptiSplint) or a laboratory scanner (Lab‐OptiSplint). Each scanning method was combined with each of the three prosthesis design–luting protocol combinations: (1) Ti‐base with freehand cementation, (2) Ti‐base cementation on a verification cast, and (3) Direct‐to‐MUA design, resulting in six experimental groups ( n = 10 per group; N = 60). All prostheses were milled from pre‐polymerized polymethylmethacrylate (PMMA) pucks using a five‐axis milling unit. All PMMA ISCFDPs were evaluated for passive fit on the master cast using the screw‐resistance test by two calibrated examiners, with discrepancies resolved by a third. Misfit was determined when incomplete seating or abnormal resistance was detected during sequential screw tightening. Inter‐examiner reliability was assessed using Cohen's kappa, and misfit rates were compared via Fisher's exact tests ( α = 0.05).

Results

Inter‐examiner agreement was excellent (98%; κ = 0.95). Laboratory scanning achieved complete passive fit across all three prosthesis design–luting protocol combinations. With the IOS workflow, Ti‐base on Cast demonstrated 0% misfit, Ti‐base Freehand exhibited 30% misfit, and Direct‐to‐MUA demonstrated 100% misfit. Group 3 exhibited a significantly higher misfit frequency than all other groups ( p < 0.001), whereas no other pairwise comparisons were significant.

Conclusion

Laboratory scanning of a non‐calibrated splinting grammetry system was associated with consistently complete passive fit across all groups. It may provide a predictable approach for achieving passive fit in complete‐arch interim prostheses. Extraoral scanning with an intraoral scanner yielded variable results, underscoring the value of verification‐cast cementation when using Ti‐bases. Within the limitations of this study, the results suggest that Direct‐to‐MUA workflows may require laboratory‐based scanning when using the evaluated systems.

Schlagwörter

Stichwörter der Autor:innen

CAD–CAMdigital impressionfull‐archscrew‐retained prosthesisverification jig

Autor:innen und Institutionen

  • Department of Prosthodontics, Indiana University School of Dentistry, Indianapolis, Indiana, USA.

ORCID-Profile: Daizo Ishiguro, Mohamed Sherif Omar, Wei-Shao Lin, Toshiki Nagai

Zitieren

APA

Ishiguro, D., Omar, M. S., Lin, W. S., & Nagai, T. (2026). Effects of scanner type and prosthesis design–luting protocol combinations on the passive fit of interim implant‐supported complete‐arch fixed dental prostheses. Journal of Prosthodontics. https://doi.org/10.1111/jopr.70218

Vancouver

Ishiguro D, Omar MS, Lin WS, Nagai T. Effects of scanner type and prosthesis design–luting protocol combinations on the passive fit of interim implant‐supported complete‐arch fixed dental prostheses. Journal of Prosthodontics. 2026. doi:10.1111/jopr.70218

BibTeX
@article{Ishiguro2026,
  author = {Ishiguro, Daizo and Omar, Mohamed Sherif and Lin, Wei-Shao and Nagai, Toshiki},
  title = {Effects of scanner type and prosthesis design–luting protocol combinations on the passive fit of interim implant‐supported complete‐arch fixed dental prostheses},
  journal = {Journal of Prosthodontics},
  year = {2026},
  doi = {10.1111/jopr.70218}
}
Kostenlos starten →