EUVIMEDEUVIMED entdecken
Randomisierte kontrollierte StudieVergleichsstudieOpen Access

Randomized comparative crossover clinical study of mechanical and optical behavior, and oral health–related quality of life of CAD‐CAM milled and 3D‐printed complete‐arch implant‐supported interim restorations

Randomisierte vergleichende Crossover-Studie zum mechanischen und optischen Verhalten sowie zur mundgesundheitsbezogenen Lebensqualität von CAD-CAM-gefrästen und 3D-gedruckten implantatgestützten vollständigen Interimsversorgungen

Solange Vasquez-Ramos iD, Rocío Cascos, Juan Ballesteros-Martínez, Marta Revilla-León iD, Miguel Gómez-Polo iD

Journal of Prosthodontics · 2026-08 · 35 (7) · 1021-1030

DOI: 10.1111/jopr.70186 ↗

Auf einen Blick

Bei 20 zahnlosen Patient:innen waren gefräste PMMA-Interimsversorgungen mechanisch günstiger als 3D-gedruckte. Passung, Optik und patientenberichtete Outcomes wurden ebenfalls verglichen.

Fragestellung

Vergleich von mechanischen Komplikationen, passiver Passung, optischem Verhalten und mundgesundheitsbezogener Lebensqualität zwischen gefrästem PMMA und 3D-gedruckter Hybridkeramik-Interimsversorgung.

Methode

Randomisierte Crossover-Studie; 20 zahnlose Patient:innen erhielten je 1 gefräste PMMA- und 1 3D-gedruckte Versorgung, jeweils 3 Monate; Auswertung mit Wilcoxon- und McNemar-Test.

Ergebnisse

Mechanische Komplikationen waren seltener mit gefrästem PMMA als mit 3D-Druck (10 % vs. 45 %; p = 0,016; Risikodifferenz +35,0 Prozentpunkte; 95 %-KI 9,5–60,5). Passiver Sitz unterschied sich nicht.

Schlussfolgerung der Autor:innen

Gefrästes PMMA zeigte ein günstigeres mechanisches Verhalten. Beide Materialien zeigten passiven Sitz, stabiles optisches Verhalten und Verbesserungen der patientenberichteten Outcomes über 3 Monate.

Kernaussagen

  • Mechanische Komplikationen: 10 % vs. 45 % zugunsten von PMMA
  • Passiver Sitz ohne signifikanten Unterschied
  • OHIP-14 verbesserte sich mit beiden Materialien

Deutsche Zusammenfassung: KI-gestützt aus dem Original-Abstract erstellt; alle Zahlen wurden automatisch mit dem Original abgeglichen. Maßgeblich ist der Original-Abstract.

Kurz gefasst

Randomisierte kontrollierte Studie in der Zeitschrift Journal of Prosthodontics, online erschienen am 06.07.2026. Verfasst von Solange Vasquez-Ramos und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Conservative Dentistry and Prosthodontics, School of Dentistry, Complutense University of Madrid, Madrid, Spain. Hauptthemen laut MEDLINE: Quality of Life, Printing, Three-Dimensional, Computer-Aided Design, Dental Prosthesis, Implant-Supported. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 55 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar. Gefördert von: Alpha Bio Tec Dental Implants Ltd..

Auf einen BlickAbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

Clinical evidence regarding 3D‐printed complete arch interim prostheses remains limited. This randomized crossover trial was designed to compare mechanical complications between milled polymethylmethacrylate (PMMA) and a hybrid ceramic 3D‐printed interim restoration and assess mechanical complications, passive fit, optical behavior, and oral health–related quality of life. Materials and Methods Twenty edentulous patients received two complete arch interim prostheses, one milled PMMA and one hybrid ceramic resin 3D‐printed restoration, each used for 3 months in a randomized crossover sequence. Mechanical complications, passive fit, optical parameters (L*, a*, b *, Δ E 00), and oral health–related quality of life were assessed. Paired nonparametric tests, including the Wilcoxon signed‐rank test and McNemar test, were applied (α = 0.05), and risk differences with 95% confidence intervals were calculated.

Results

Milled PMMA exhibited fewer mechanical complications than 3D‐printed (10% vs. 45%; p = 0.016; risk difference +35.0 percentage points; 95% CI: 9.5–60.5). Passive fit showed no statistically significant differences between materials ( p = 0.500). Mean Δ E 00 did not differ significantly (PMMA 4.68 ± 6.57; 3D‐printed 4.73 ± 4.75; p = 0.243). The 3D‐printed material presented higher L * values at both evaluations ( p < 0.001) and a significant increase in a * over time ( p = 0.008). Both materials improved Oral Health Impact Profile‐14 scores; at 3 months, 3D‐printed prostheses showed slightly lower scores than PMMA ( p = 0.045).

Conclusions

Milled PMMA showed more favorable mechanical performance. Both materials demonstrated passive fit, stable optical behavior, and improvements in patient‐reported outcomes during the 3‐month period. Trial Registration ClinicalTrials.gov identifier: NCT05958043.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Quality of LifePrinting, Three-DimensionalComputer-Aided DesignDental Prosthesis, Implant-SupportedOral HealthHumansCross-Over StudiesPolymethyl MethacrylateFemaleMiddle AgedMaleAgedCeramicsDental Marginal AdaptationDenture Design

Stichwörter der Autor:innen

3D printingCAD‐CAMimplant‐supported dental prosthesispolymethylmethacrylateprovisional restorationquality of life

Substanzen

Polymethyl Methacrylate

Autor:innen und Institutionen

  • Department of Conservative Dentistry and Prosthodontics, School of Dentistry, Complutense University of Madrid, Madrid, Spain.
  • Advanced Implant-Prosthodontics Postgraduate Program, School of Dentistry, Complutense University of Madrid, Madrid, Spain.
  • Department of Restorative Dentistry, School of Dentistry, University of Washington, Seattle, Washington, USA.
  • Research, and Digital Dentistry, Kois Center, Seattle, Washington, USA.
  • Department of, Prosthodontics, School of Dental Medicine, Tufts University, Boston, Massachusetts, USA.

ORCID-Profile: Solange Vasquez-Ramos, Marta Revilla-León, Miguel Gómez-Polo

Förderung

  • Alpha Bio Tec Dental Implants Ltd.

Zitieren

APA

Vasquez-Ramos, S., Cascos, R., Ballesteros-Martínez, J., Revilla-León, M., & Gómez-Polo, M. (2026). Randomized comparative crossover clinical study of mechanical and optical behavior, and oral health–related quality of life of CAD‐CAM milled and 3D‐printed complete‐arch implant‐supported interim restorations. Journal of Prosthodontics, 35(7), 1021-1030. https://doi.org/10.1111/jopr.70186

Vancouver

Vasquez-Ramos S, Cascos R, Ballesteros-Martínez J, Revilla-León M, Gómez-Polo M. Randomized comparative crossover clinical study of mechanical and optical behavior, and oral health–related quality of life of CAD‐CAM milled and 3D‐printed complete‐arch implant‐supported interim restorations. Journal of Prosthodontics. 2026;35(7):1021-1030. doi:10.1111/jopr.70186

BibTeX
@article{VasquezRamos2026,
  author = {Vasquez-Ramos, Solange and Cascos, Rocío and Ballesteros-Martínez, Juan and Revilla-León, Marta and Gómez-Polo, Miguel},
  title = {Randomized comparative crossover clinical study of mechanical and optical behavior, and oral health–related quality of life of CAD‐CAM milled and 3D‐printed complete‐arch implant‐supported interim restorations},
  journal = {Journal of Prosthodontics},
  year = {2026},
  volume = {35},
  number = {7},
  pages = {1021--1030},
  doi = {10.1111/jopr.70186}
}
Kostenlos starten →