Acrylic resin versus metal palatal base in complete dentures: A randomized crossover clinical trial of patient‐reported outcomes
Journal of Prosthodontics · 2025
DOI: 10.1111/jopr.70001 ↗Kurz gefasst
Randomisierte kontrollierte Studie in der Zeitschrift Journal of Prosthodontics, 2025. Verfasst von Motasum Abu-Awwad und 5 weiteren Autor:innen. Beteiligte Einrichtung: Prosthodontics Department, University of Jordan School of Dentistry, Amman, Jordan. Hauptthemen laut MEDLINE: Patient Reported Outcome Measures, Denture, Complete, Acrylic Resins, Denture Bases. Die Arbeit nennt 31 Literaturangaben. Gefördert von: Deanship of Academic Research at the University of Jordan, Amman, Jordan.
Abstract (Originalsprache)
Purpose
To compare the effects of acrylic resin and metal palatal bases in complete dentures on patient satisfaction and quality of life. Materials and Methods This randomized, two‐period crossover clinical trial involved 30 edentulous participants. Each received complete dentures with either an acrylic resin or a metal palatal base, followed by the alternative after 2 months. Participant satisfaction was assessed using a visual analog scale, and quality of life was evaluated via the Oral Health Impact Profile for Edentulous Patients (OHIP‐EDENT). The Wilcoxon signed‐rank test and effect size (ES) analyze satisfaction ratings and OHIP‐EDENT scores. Regression analysis was conducted to identify predictors of general satisfaction and OHIP‐EDENT scores. Fisher's exact test assessed the association between denture wearing experience and material preference.
Results
Of the 30 participants, 25 completed the study (48% first‐time wearers, 52% experienced wearers). No statistically significant differences were found for general satisfaction ( p = 0.386), eating ( p = 0.292), taste ( p = 0.775), speech ( p = 0.497), phonetics ( p = 0.570), cleaning ( p = 0.905), palate design ( p = 0.773), or OHIP‐EDENT score ( p = 0.381). Phonetics demonstrated a moderate ES ( r = 0.38) in favor of metal bases. Other domains had small ES ( r = 0.02–0.21). Metal bases were associated with increased embarrassment ( p = 0.034, r = 0.42). Regression analyses revealed no significant predictors of general satisfaction ( p = 0.397) or OHIP‐EDENT scores ( p = 0.685). First‐time wearers tended to prefer acrylic resin bases; experienced wearers were evenly divided ( p = 0.097).
Conclusion
Both acrylic resin and metal palatal bases yielded comparable satisfaction and quality of life outcomes. However, metal bases caused more embarrassment. Material preference appeared to vary based on prior denture‐wearing experience.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Prosthodontics Department, University of Jordan School of Dentistry, Amman, Jordan.
Förderung
- Deanship of Academic Research at the University of Jordan, Amman, Jordan
Zitieren
APA
Abu-Awwad, M., Hailkal, L., Bustani, M., Ereifej, N., Baker, D. A., & Al-Omiri, M. K. (2025). Acrylic resin versus metal palatal base in complete dentures: A randomized crossover clinical trial of patient‐reported outcomes. Journal of Prosthodontics. https://doi.org/10.1111/jopr.70001
Vancouver
Abu-Awwad M, Hailkal L, Bustani M, Ereifej N, Baker DA, Al-Omiri MK. Acrylic resin versus metal palatal base in complete dentures: A randomized crossover clinical trial of patient‐reported outcomes. Journal of Prosthodontics. 2025. doi:10.1111/jopr.70001
BibTeX
@article{AbuAwwad2025,
author = {Abu-Awwad, Motasum and Hailkal, Laila and Bustani, Mohammad and Ereifej, Nadia and Baker, Dima Abu and Al-Omiri, Mahmoud K},
title = {Acrylic resin versus metal palatal base in complete dentures: A randomized crossover clinical trial of patient‐reported outcomes},
journal = {Journal of Prosthodontics},
year = {2025},
doi = {10.1111/jopr.70001}
}
EUVIMED