Fachartikel in der Zeitschrift Journal of Prosthodontics, 2024. Verfasst von Jung-Min Yoon und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Prosthodontics, Peking University School and Hospital of Stomatology & National Center of Stomatology & National Clinical Research Cent…. Hauptthemen laut MEDLINE: Denture, Partial, Removable, Benzophenones, Ketones, Polymers. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 44 Literaturangaben. Gefördert von: Key Research and Development Program of Shandong Province, Capital's Funds for Health Improvement and Research, National Natural Science Foundation of China.
Abstract (Originalsprache)
Purpose
To explore the clinical application of one‐piece polyetheretherketone (PEEK) removable partial dentures (RPDs) fabricated using a novel digital workflow and to evaluate their weights and fits in vivo and patient satisfaction. Materials and Methods Fifteen cases with posterior partially edentulous situations were selected, and each patient received two types of RPDs, including a novel digital workflow (test group) and a conventional workflow (control group). For the test group, one‐piece RPDs were designed through three‐dimensional (3D) methods by scanning stone casts and fabricated by milling PEEK discs. Each RPD was weighed. The gaps between the oral tissue and RPDs in each group were duplicated using a polyvinylsiloxane (PVS) replica and measured by 3D analysis. A visual analog scale (VAS) was used to evaluate the patient's satisfaction. Paired t ‐tests were used to compare the differences in the weight, the gaps of each RPD, and VAS values between the two groups. One‐way analysis of variance tests was used to compare the differences in the gap among different components in each group.
Results
The RPD in the test group weighed less than that in the control group ( p < 0.01). No statistically significant differences in the gaps of denture bases and rests ( p > 0.05) were found between the two groups, but the gaps of major connectors in the test group were significantly smaller than in the control group ( p < 0.05). The VAS scores for comfortableness and masticatory efficiency were not significantly different between the two groups ( p > 0.05) but the scores for the aesthetic appearance of the clasps in the test group were significantly higher than that in the control group ( p < 0.05).
Conclusions
One‐piece PEEK RPDs manufactured using a novel digital workflow weighed less than conventional RPDs and exhibited a clinically acceptable internal fit. Although the aesthetic appearance of the PEEK clasps was superior to the control, there is still room for improvement.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Prosthodontics, Peking University School and Hospital of Stomatology & National Center of Stomatology & National Clinical Research Center for Oral Diseases & National Engineering Research Center of Oral Bi…
- Center of Digital Dentistry, Peking University School and Hospital of Stomatology & National Center of Stomatology & National Clinical Research Center for Oral Diseases & National Engineering Research Center of Oral Bio…
ORCID-Profile: Yunsong Liu, Yuchun Sun, Hongqiang Ye, Yongsheng Zhou
Förderung
- Key Research and Development Program of Shandong Province
- Capital's Funds for Health Improvement and Research
- National Natural Science Foundation of China
- Key Technology Research and Development Program of Shandong Province
Zitieren
APA
Yoon, J. M., Liu, Y., Sun, Y., Ye, H., & Zhou, Y. (2024). Clinical evaluation of a one‐piece polyetheretherketone removable partial denture fabricated using a novel digital workflow: A self‐controlled clinical trial. Journal of Prosthodontics. https://doi.org/10.1111/jopr.13907
Vancouver
Yoon JM, Liu Y, Sun Y, Ye H, Zhou Y. Clinical evaluation of a one‐piece polyetheretherketone removable partial denture fabricated using a novel digital workflow: A self‐controlled clinical trial. Journal of Prosthodontics. 2024. doi:10.1111/jopr.13907
BibTeX
@article{Yoon2024,
author = {Yoon, Jung-Min and Liu, Yunsong and Sun, Yuchun and Ye, Hongqiang and Zhou, Yongsheng},
title = {Clinical evaluation of a one‐piece polyetheretherketone removable partial denture fabricated using a novel digital workflow: A self‐controlled clinical trial},
journal = {Journal of Prosthodontics},
year = {2024},
doi = {10.1111/jopr.13907}
}
EUVIMED