Fachartikel in der Zeitschrift Journal of Prosthodontics, 2025. Verfasst von Chih-Wei Tseng und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Dentistry, Wan-Fang Hospital, Taipei Medical University, Taipei, Taiwan. Hauptthemen laut MEDLINE: Printing, Three-Dimensional, Models, Dental, Dental Prosthesis Design, Liquid Crystals. Die Arbeit wurde bisher 11-mal zitiert (Crossref) und nennt 46 Literaturangaben. Gefördert von: Taipei Medical University College of Oral Medicine, Taiwan.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

To evaluate the effects of two base types and three restoration designs on the resin consumption and trueness of the 3D‐printed dental casts. Additionally, the study explored the dimensional stability of these 3D‐printed dental casts after 1 year of storage. Materials and Methods Various types of reference dental casts were specifically designed to represent three types of dental restoration fabrications, including full‐arch (FA), long‐span (LS), and single‐unit (SU) prostheses. The reference casts were digitized with a dental laboratory scanner and used to create flat and hollow base designs ( N = 18) for the 3D‐printed study casts. The 3D‐printed study casts were digitized and evaluated against their corresponding references immediately after 3D printing and again after 1 year of storage, with the trueness quantified using the root mean square error (RMSE) at both time points. Volumes of resin used were recorded to measure resin consumption, and the weights of the 3D‐printed study casts were also measured. The data were analyzed using two‐way ANOVA and a Tukey post hoc test, α = 0.05.

Results

Volumetric analysis showed the flat‐base design had significantly higher resin consumption with weights for the FA group at 42.51 ± 0.16 g, the LS group at 31.64 ± 0.07 g, and the SU group at 27.67 ± 0.31 g, as opposed to 26.22 ± 1.01 g, 22.86 ± 0.93 g, and 20.10 ± 0.19 g for the hollow designs respectively ( p < 0.001). Trueness, assessed through two‐way ANOVA, revealed that the flat‐base design had lower RMSE values indicating better trueness in the LS (54 ± 6 µm) and SU (59 ± 7 µm) groups compared to the hollow‐base design (LS: 73 ± 5, SU: 99 ± 11 µm, both p < 0.001), with no significant difference in the FA group (flat‐base: 50 ± 3, hollow: 47 ± 5 µm, p = 0.398). After 1 year, the flat‐base design demonstrated superior dimensional stability in the LS (flat base: 56 ± 6 µm, hollow base: 149 ±45 µm, p < 0.001) and SU groups (flat base: 95 ± 8 µm, hollow base: 183 ±27 µm, p < 0.001), with the FA group showing no significant difference in the base design (flat base: 47 ± 9, hollow base: 62 ± 12 µm, p = 0.428).

Conclusions

The hollow‐base design group showed lower resin consumption than the flat‐base design group. However, the flat‐base designs exhibited superior trueness and less distortion after 1 year of storage. These findings indicate that despite the higher material usage, flat‐base designs provide better initial accuracy and maintain their dimensional stability over time for most groups.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Printing, Three-DimensionalModels, DentalDental Prosthesis DesignLiquid CrystalsDental MaterialsResins, SyntheticDental Restoration, PermanentHumansComputer-Aided DesignDental Casting Technique

Stichwörter der Autor:innen

3D printingdental resinsprosthesis typesprosthodonticstrueness

Substanzen

Dental MaterialsResins, Synthetic

Autor:innen und Institutionen

  • Department of Dentistry, Wan-Fang Hospital, Taipei Medical University, Taipei, Taiwan.
  • Department of Prosthodontics, Indiana University School of Dentistry, Indianapolis, Indiana, USA.
  • School of Dentistry, College of Oral Medicine, Taipei Medical University, Taipei, Taiwan.
  • School of Dental Technology, College of Oral Medicine, Taipei Medical University, Taipei, Taiwan.
  • Center for Tooth Bank and Dental Stem Cell Technology, Taipei Medical University, Taipei, Taiwan.

ORCID-Profile: Wei-Shao Lin, Wei-Chun Lin

Förderung

  • Taipei Medical University College of Oral Medicine, Taiwan

Zitieren

APA

Tseng, C. W., Lin, W. S., Sahrir, C. D., & Lin, W. C. (2025). The impact of base design and restoration type on the resin consumption, trueness, and dimensional stability of dental casts additively manufactured from liquid crystal display 3D printers. Journal of Prosthodontics. https://doi.org/10.1111/jopr.13864

Vancouver

Tseng CW, Lin WS, Sahrir CD, Lin WC. The impact of base design and restoration type on the resin consumption, trueness, and dimensional stability of dental casts additively manufactured from liquid crystal display 3D printers. Journal of Prosthodontics. 2025. doi:10.1111/jopr.13864

BibTeX
@article{Tseng2025,
  author = {Tseng, Chih-Wei and Lin, Wei-Shao and Sahrir, Citra Dewi and Lin, Wei-Chun},
  title = {The impact of base design and restoration type on the resin consumption, trueness, and dimensional stability of dental casts additively manufactured from liquid crystal display 3D printers},
  journal = {Journal of Prosthodontics},
  year = {2025},
  doi = {10.1111/jopr.13864}
}
Kostenlos starten →