Fachartikel in der Zeitschrift Journal of Prosthodontics, 2024. Verfasst von Masumeh Taghva und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Prosthodontics, School of Dentistry, Shiraz University of Medical Sciences, Shiraz, Iran. Hauptthemen laut MEDLINE: Dental Impression Technique, Dental Implants. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 61 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

The purpose of this in vitro investigation was to assess how implant depth could affect the three‐dimensional positional accuracy of digital impressions made from angulated implants. Materials and Methods Four modified maxillary models were printed and divided into four study groups. In each model, two angulated implant analogs were placed at the sites of the first premolar and first molar at four different depths of 1 (G1), 2 (G2), 3 (G3), and 4 (G4) mm from the models' edentate area. Scan bodies were connected to the analogs, and one operator made 10 full‐arch scans for each master model using an intraoral scanner. Afterward, the marginal gingival part of all models was removed, and digital scans were performed for each model using a laboratory scanner to achieve a reference STL file as the control group. One‐way ANOVA and Leven's tests were used to measure and compare the 3D distance deviations across research groups after the superimposing test and control scans.

Results

A significant difference between research groups was revealed by trueness and precision analysis ( p < 0.001). The trueness and precision results obtained for G1 and G4 were significantly better than those for G2 and G3 ( p < 0.05).

Conclusion

This study demonstrated that implant depth could affect the digital implant impressions' 3D positional accuracy.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Dental Impression TechniqueDental ImplantsHumansIn Vitro TechniquesComputer-Aided DesignModels, DentalImaging, Three-DimensionalDental Prosthesis DesignMaxilla

Stichwörter der Autor:innen

analog‐digital conversiondental implantationdental implantsdental impression techniquedental prosthesisdigital technologyimplant‐supported dental prosthesis

Substanzen

Dental Implants

Autor:innen und Institutionen

  • Department of Prosthodontics, School of Dentistry, Shiraz University of Medical Sciences, Shiraz, Iran.
  • Student Research Committee, School of Dentistry, Shiraz University of Medical Sciences, Shiraz, Iran.
  • Nanomedicine and Nanobiology Research Center, Department of Prosthodontics, School of Dentistry, Shiraz University of Medical Sciences, Shiraz, Iran.
  • School of Dentistry, Shiraz University of Medical Sciences, Shiraz, Iran.

ORCID-Profile: Masumeh Taghva, Seyed Ali Mosaddad

Zitieren

APA

Taghva, M., Mosaddad, S. A., Ansarifard, E., & Sadeghi, M. (2024). Could various angulated implant depths affect the positional accuracy of digital impressions? An in vitro study. Journal of Prosthodontics. https://doi.org/10.1111/jopr.13764

Vancouver

Taghva M, Mosaddad SA, Ansarifard E, Sadeghi M. Could various angulated implant depths affect the positional accuracy of digital impressions? An in vitro study. Journal of Prosthodontics. 2024. doi:10.1111/jopr.13764

BibTeX
@article{Taghva2024,
  author = {Taghva, Masumeh and Mosaddad, Seyed Ali and Ansarifard, Elham and Sadeghi, Mohsen},
  title = {Could various angulated implant depths affect the positional accuracy of digital impressions? An in vitro study},
  journal = {Journal of Prosthodontics},
  year = {2024},
  doi = {10.1111/jopr.13764}
}
Kostenlos starten →