EUVIMEDEUVIMED entdecken
Crossref

Biomechanical effects of different materials for an occlusal device on implant‐supported rehabilitation in a tooth clenching situation: A 3D finite element analysis

Carla Souza Andrade, Luy de Abreu Costa, Luana Gonçalves Menechelli, Cleidiel A A Lemos iD, Roberta Okamoto, Fellippo R Verri iD, Victor Eduardo de Souza Batista iD

Journal of Prosthodontics · 2024

DOI: 10.1111/jopr.13763 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Prosthodontics, 2024. Verfasst von Carla Souza Andrade und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Prosthodontics, Presidente Prudente Dental School, University of Western São Paulo - UNOESTE, Presidente Prudente, Brazil. Hauptthemen laut MEDLINE: Finite Element Analysis, Dental Prosthesis, Implant-Supported. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 58 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

The purpose of this 3D finite element analysis was to evaluate the biomechanical effects of different materials used to fabricate occlusal devices to achieve stress distribution in simulated abutment screws, dental implants, and peri‐implant bone tissue in individuals who clench their teeth. Materials and Methods Eight 3D models simulated a posterior maxillary bone block with three external hexagon implants (Ø4.0 × 7.0 mm) supporting a 3‐unit screw‐retained metal‐ceramic prosthesis with different crown connection (splinting), and the use of an occlusal device (OD). The OD was modeled to be 2‐mm thick. ANSYS 19.2 software was used to generate the finite‐element models in the pre‐and post‐processing phases. Simulated abutment screws and dental implants were evaluated by von Mises stress maps, and simulated bone was evaluated by maximum principal stress and microstrain maps by using a finite element software program.

Results

The highest stress values in the dental implants and screws were observed in single crowns without OD (M1). Furthermore, the highest stress values and bone tissue strain were found in single crowns without OD (M1). The simulated material for the OD did not cause many discrepancies in terms of the stress magnitude in the simulated dental implant and abutment screw for both single and splinted crowns; however, more rigid materials exhibited lower stress values.

Conclusion

The use of OD was effective in reducing stress in the simulated implants and abutment screws and stress and strain in the simulated bone tissue. The material used to simulate the OD influenced the biomechanical behavior of implant‐supported fixed prostheses, whereas splints with rigid materials such as PEEK and PMMA exhibited better biomechanical behavior.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Finite Element AnalysisDental Prosthesis, Implant-SupportedHumansBiomechanical PhenomenaDental Stress AnalysisDental MaterialsImaging, Three-DimensionalCrownsDental AbutmentsDental Implants

Stichwörter der Autor:innen

biomechanical phenomenadental implantsfinite element analysis

Substanzen

Dental MaterialsDental Implants

Autor:innen und Institutionen

  • Department of Prosthodontics, Presidente Prudente Dental School, University of Western São Paulo - UNOESTE, Presidente Prudente, Brazil.
  • Department of Diagnosis and Surgery, Araçatuba Dental School, São Paulo State University Júlio de Mesquita Filho-UNESP, Araçatuba, Brazil.
  • Department of Dentistry (Division of Prosthodontics), Federal University of Juiz de Fora, Campus Avançado Governador Valadares (UFJF/GV), Governador Valadares, Minas Gerais, Brazil.
  • Department of Basic Sciences, Universidade Estadual Paulista Júlio de Mesquita Filho, School of Dentistry at Araçatuba, Araçatuba, Brazil.
  • Department of Dental Materials and Prosthodontics, Araçatuba Dental School, São Paulo State University Júlio de Mesquita Filho-UNESP, Araçatuba, Brazil.
  • Postgraduate Program in Dentistry - Implantology concentration area, Araçatuba Dental School, São Paulo State University Júlio de Mesquita Filho-UNESP, Araçatuba, Brazil.

ORCID-Profile: Cleidiel A A Lemos, Fellippo R Verri, Victor Eduardo de Souza Batista

Zitieren

APA

Andrade, C. S., de Abreu Costa, L., Menechelli, L. G., Lemos, C. A. A., Okamoto, R., Verri, F. R., & de Souza Batista, V. E. (2024). Biomechanical effects of different materials for an occlusal device on implant‐supported rehabilitation in a tooth clenching situation: A 3D finite element analysis. Journal of Prosthodontics. https://doi.org/10.1111/jopr.13763

Vancouver

Andrade CS, de Abreu Costa L, Menechelli LG, Lemos CAA, Okamoto R, Verri FR, et al. Biomechanical effects of different materials for an occlusal device on implant‐supported rehabilitation in a tooth clenching situation: A 3D finite element analysis. Journal of Prosthodontics. 2024. doi:10.1111/jopr.13763

BibTeX
@article{Andrade2024,
  author = {Andrade, Carla Souza and de Abreu Costa, Luy and Menechelli, Luana Gonçalves and Lemos, Cleidiel A A and Okamoto, Roberta and Verri, Fellippo R and de Souza Batista, Victor Eduardo},
  title = {Biomechanical effects of different materials for an occlusal device on implant‐supported rehabilitation in a tooth clenching situation: A 3D finite element analysis},
  journal = {Journal of Prosthodontics},
  year = {2024},
  doi = {10.1111/jopr.13763}
}
Kostenlos starten →