EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC-ND 4.0

Comparison of efficacy and usability of custom mandibular advancement devices fabricated with the conventional method and digital workflow: A pilot clinical study

Bulent Piskin iD, Tuba Yılmaz Savaş iD, Sila Caglayan Topal, Kuddusi Akbulut iD, Bahadir Ezmek iD, Alper Uyar, Nesrin Sahin, Omer Karakoc

Journal of Prosthodontics · 2024-02 · 33 (2) · 123-131

DOI: 10.1111/jopr.13720 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Prosthodontics, online erschienen am 06.07.2023. Verfasst von Bulent Piskin und 7 weiteren Autor:innen. Beteiligte Einrichtung: Department of Prosthodontics, Faculty of Dentistry, Cappadocia University, Nevşehir, Turkey. Hauptthemen laut MEDLINE: Sleep Apnea, Obstructive, Mandibular Advancement. Die Arbeit wurde bisher 11-mal zitiert (Crossref) und nennt 43 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

To compare the effects of fabricating methods of custom monoblock mandibular advancement devices (MADs) on usability and efficacy in patients with mild and moderate obstructive sleep apnea (OSA). Materials and Methods Digitally fabricated custom MADs (dMADs) were produced for 11 OSA participants who had previously used conventionally fabricated custom MADs (cMADs). The participants answered a modified usability questionnaire for both MADs, and the average scores that were given to the questionnaire were evaluated by age, sex, and body mass index (BMI), and the scores of cMADs and dMADs were compared. After 6 months of usage of each MAD, the apnea‐hypopnea index (AHI), mean and lowest oxygen saturations, and total sleep time were measured for efficacy assessment. Data were analyzed with Cronbach's alpha, Mann‐Whitney U, Kruskal‐Wallis, Wilcoxon signed‐rank, one‐way repeated measures analyses of variance, and Bonferroni tests ( α = 0.05).

Results

Cronbach's alpha was found at 0.834 and 0.722 for the conventional and digital questionnaires, respectively. The usability scores of the dMADs were significantly higher than those of cMADs ( p = 0.013). There was no difference in usability scores in terms of sex or BMI ( p > 0.05). No statistically significant difference was found for cMAD ( p = 0.113) among age groups; however, there was a significant difference for dMAD ( p = 0.046). The AHI, mean, and lowest oxygen saturation values were significantly affected by MAD usage ( p < 0.001). However, total sleep time values did not differ after the MAD treatments ( p > 0.05). Significantly lower AHI and significantly higher lowest oxygen saturation values were observed with dMAD, while both appliances led to similar results for mean oxygen saturation and total sleep time values ( p > 0.05).

Conclusions

Participant usability scores were higher for digitally manufactured MADs than conventionally manufactured MADs. However, both conventional and digital MADs were found effective in decreasing the AHI levels and increasing the mean and lowest oxygen saturation values of the participants.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Sleep Apnea, ObstructiveMandibular AdvancementHumansTreatment OutcomeOcclusal SplintsWorkflow

Stichwörter der Autor:innen

CAD-CAMadditive manufacturingconventional manufacturingmandibular advancement deviceobstructive sleep apneausability

Autor:innen und Institutionen

  • Department of Prosthodontics, Faculty of Dentistry, Cappadocia University, Nevşehir, Turkey.
  • Department of Prosthodontics, Faculty of Dentistry, Selçuk University, Konya, Turkey.
  • Department of Orthodontics, Bayındır Hospital, Ankara, Turkey.
  • Department of Prosthodontics, Gülhane Faculty of Dentistry, Health Sciences University, Ankara, Turkey.
  • Center of Dental Technologies, Cappadocia Vocational College, Cappadocia University, Nevşehir, Turkey.
  • Department of Otolaryngology, Head and Neck Surgery, Gülhane Faculty of Medicine, Health Sciences University, Ankara, Turkey.

ORCID-Profile: Bulent Piskin, Tuba Yılmaz Savaş, Kuddusi Akbulut, Bahadir Ezmek

Zitieren

APA

Piskin, B., Yılmaz Savaş, T., Topal, S. C., Akbulut, K., Ezmek, B., Uyar, A., Sahin, N., & Karakoc, O. (2024). Comparison of efficacy and usability of custom mandibular advancement devices fabricated with the conventional method and digital workflow: A pilot clinical study. Journal of Prosthodontics, 33(2), 123-131. https://doi.org/10.1111/jopr.13720

Vancouver

Piskin B, Yılmaz Savaş T, Topal SC, Akbulut K, Ezmek B, Uyar A, et al. Comparison of efficacy and usability of custom mandibular advancement devices fabricated with the conventional method and digital workflow: A pilot clinical study. Journal of Prosthodontics. 2024;33(2):123-131. doi:10.1111/jopr.13720

BibTeX
@article{Piskin2024,
  author = {Piskin, Bulent and Yılmaz Savaş, Tuba and Topal, Sila Caglayan and Akbulut, Kuddusi and Ezmek, Bahadir and Uyar, Alper and Sahin, Nesrin and Karakoc, Omer},
  title = {Comparison of efficacy and usability of custom mandibular advancement devices fabricated with the conventional method and digital workflow: A pilot clinical study},
  journal = {Journal of Prosthodontics},
  year = {2024},
  volume = {33},
  number = {2},
  pages = {123--131},
  doi = {10.1111/jopr.13720}
}
Kostenlos starten →