Reverse scan body: A complete digital workflow for prosthesis prototype fabrication
Journal of Prosthodontics · 2023
DOI: 10.1111/jopr.13664 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Prosthodontics, 2023. Verfasst von Panos Papaspyridakos und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Prosthodontics, Tufts University School of Dental Medicine, Boston, Massachusetts, USA. Hauptthemen laut MEDLINE: Dental Prosthesis, Implant-Supported, Dental Implants. Die Arbeit wurde bisher 30-mal zitiert (Crossref) und nennt 24 Literaturangaben.
Abstract (Originalsprache)
Purpose
To assess the accuracy of fit of prosthesis prototypes fabricated via a complete digital workflow protocol with a reverse scan body skipping intraoral scanning for implant data acquisition. Materials and methods A maxillary stone cast with four multiunit abutment implant analogs (Screw‐Retained Abutments, Institut Straumann AG, Basel, Switzerland) with adequate anteroposterior spread simulated a common clinical patient situation. This stone cast served as the master cast and an interim screw‐retained prosthesis was fabricated on it. Novel reverse scan bodies were connected to the interim prosthesis, and extraoral scanning was performed with a white light intraoral scanner. The produced standard tessellation language (STL) files were then imported to computer‐assisted design software and after the digital design, the STL file was exported to a computer‐assisted machining milling machine and a three‐dimensional (3D) printer to produce a total of 50 milled and 50 printed fixed complete denture prototypes, respectively. Two clinicians assessed the accuracy of fit of each digitally fabricated prosthesis prototype on the master cast, utilizing the screw‐resistance test and radiographic evaluation. Out of the 100 prototypes, 94% (94/100) were fitting accurately. Fisher's exact test was used to test the difference among the groups. The test revealed statistically significant results ( p = 0.027).
Results
Out of the 50 digitally fabricated milled prosthesis prototypes, 50 (100%) presented with accurate fit under in vitro assessment. Out of the 50 digitally fabricated 3D printed prototypes, 44 (88%) presented with accurate fit under in vitro assessment.
Conclusions
Accurately fitting digitally fabricated prosthesis prototypes can be milled after extraoral scanning with reverse scan bodies without intraoral implant data acquisition.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Substanzen
Autor:innen und Institutionen
- Department of Prosthodontics, Tufts University School of Dental Medicine, Boston, Massachusetts, USA.
- Department of Prosthodontics, Eastman Institute for Oral Health, University of Rochester, Rochester, New York, USA.
- Department of Prosthodontics, University of Washington, Seattle, Washington, USA.
- Department of Dental Public Health, Faculty of Dentistry, King Abdulaziz University, Jeddah, Saudi Arabia.
ORCID-Profile: Panos Papaspyridakos, Armand Bedrossian, Panagiotis Ntovas, Konstantinos Chochlidakis
Zitieren
APA
Papaspyridakos, P., Bedrossian, A., Kudara, Y., Ntovas, P., Bokhary, A., & Chochlidakis, K. (2023). Reverse scan body: A complete digital workflow for prosthesis prototype fabrication. Journal of Prosthodontics. https://doi.org/10.1111/jopr.13664
Vancouver
Papaspyridakos P, Bedrossian A, Kudara Y, Ntovas P, Bokhary A, Chochlidakis K. Reverse scan body: A complete digital workflow for prosthesis prototype fabrication. Journal of Prosthodontics. 2023. doi:10.1111/jopr.13664
BibTeX
@article{Papaspyridakos2023,
author = {Papaspyridakos, Panos and Bedrossian, Armand and Kudara, Yukio and Ntovas, Panagiotis and Bokhary, Abdullah and Chochlidakis, Konstantinos},
title = {Reverse scan body: A complete digital workflow for prosthesis prototype fabrication},
journal = {Journal of Prosthodontics},
year = {2023},
doi = {10.1111/jopr.13664}
}
EUVIMED