EUVIMEDEUVIMED entdecken
Crossref

The accuracies of three intraoral scanners with regard to shade determination: An in vitro study

Mingming Huang iD, Yong Wang iD, Yuchun Sun iD, Yongsheng Zhou iD, Yunsong Liu iD, Hongqiang Ye iD

Journal of Prosthodontics · 2023-06 · 32 (5)

DOI: 10.1111/jopr.13571 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Prosthodontics, online erschienen am 10.08.2022. Verfasst von Mingming Huang und 5 weiteren Autor:innen. Beteiligte Einrichtung: Center of Digital Dentistry, Faculty of Prosthodontics, Peking University School and Hospital of Stomatology, National Center of Stomatology, Nationa…. Hauptthemen laut MEDLINE: Prosthesis Coloring, Research Design. Die Arbeit wurde bisher 8-mal zitiert (Crossref) und nennt 58 Literaturangaben. Gefördert von: National Key R&D Program of China, Capital Science and Technology Leading Talent Project, Program for New Clinical Techniques and Therapies of Peking University School and Hospital of Stomatology.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

To compare the accuracies of three intraoral scanners for shade determination function in vitro, and to preliminarily investigate the shade‐matching characteristics of the three intraoral scanners. Materials and Methods The shade of the middle third region of each shade tab on the Vita Classical A1‐D4 shade guide (VC) was measured with a spectrophotometer (Vita Easyshade V, VE) and three intraoral scanners, including CEREC Omnicam (OM), 3Shape TRIOS 3 (T3), and TRIOS 4 (T4). A conversion table between VC values and CIELAB values was established from the database of VE to analyze the trueness. The reproducibility of the instruments was then compared by repeating the measurements five times.

Results

The mean color difference for each instrument was highest in the OM, followed by the T4, and lowest in the T3 and VE, respectively. The L * and a * value for OM, and the b * value for T4, were significantly different from those for VE ( p

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Prosthesis ColoringResearch DesignReproducibility of ResultsSpectrophotometryColor

Stichwörter der Autor:innen

intraoral scannershade guideshade matchingspectrophotometer

Autor:innen und Institutionen

  • Center of Digital Dentistry, Faculty of Prosthodontics, Peking University School and Hospital of Stomatology, National Center of Stomatology, National Clinical Research Center for Oral Disease, National Engineering Rese…
  • Department of Prosthodontics, Peking University School and Hospital of Stomatology, National Center of Stomatology, National Clinical Research Center for Oral Disease, National Engineering Research Center of Oral Biomat…

ORCID-Profile: Mingming Huang, Yong Wang, Yuchun Sun, Yongsheng Zhou, Yunsong Liu, Hongqiang Ye

Förderung

  • National Key R&D Program of China
  • Capital Science and Technology Leading Talent Project
  • Program for New Clinical Techniques and Therapies of Peking University School and Hospital of Stomatology

Zitieren

APA

Huang, M., Wang, Y., Sun, Y., Zhou, Y., Liu, Y., & Ye, H. (2023). The accuracies of three intraoral scanners with regard to shade determination: An in vitro study. Journal of Prosthodontics, 32(5). https://doi.org/10.1111/jopr.13571

Vancouver

Huang M, Wang Y, Sun Y, Zhou Y, Liu Y, Ye H. The accuracies of three intraoral scanners with regard to shade determination: An in vitro study. Journal of Prosthodontics. 2023;32(5). doi:10.1111/jopr.13571

BibTeX
@article{Huang2023,
  author = {Huang, Mingming and Wang, Yong and Sun, Yuchun and Zhou, Yongsheng and Liu, Yunsong and Ye, Hongqiang},
  title = {The accuracies of three intraoral scanners with regard to shade determination: An in vitro study},
  journal = {Journal of Prosthodontics},
  year = {2023},
  volume = {32},
  number = {5},
  doi = {10.1111/jopr.13571}
}
Kostenlos starten →