Digital Occlusal Contact Area Indicates Masticatory Performance for Normal Occlusion, but Not for Malocclusion
Journal of Oral Rehabilitation · 2025
DOI: 10.1111/joor.14002 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Oral Rehabilitation, 2025. Verfasst von Paulina Vortkamp und 10 weiteren Autor:innen. Beteiligte Einrichtung: Department of Prosthodontics, University of Heidelberg, Heidelberg, Germany. Hauptthemen laut MEDLINE: Mastication, Malocclusion, Dental Occlusion, Dentofacial Deformities. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 20 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Objectives
Since 1949, occlusal contact area (OCA) has been recognised as an indicator of masticatory performance (MP), but it required individual and laborious analog measurement. Today, a digital workflow could provide automatic quantification.
Objective
To find optimal parameters for a digital evaluation in terms of maximising correlation between OCA and MP.
Methods
MP was measured clinically by comminution of standardised test food by 41 participants (mean age = 29, n female = 28), including 18 patients with dentofacial deformities and 23 healthy subjects with normal occlusion. OCA was measured in the laboratory. After impression taking, gypsum casts were digitised (D2000, 3shape) and aligned in maximum intercuspidation (Geomagic Design X2022, 3D Systems). The maxilla was enlarged with surface offsets of 100, 150, 200, 250, 300, 350, 400, 800 and 2000 μm to simulate different interocclusal distances. OCA was identified at the mandible surface by intersection with the respective enlarged maxilla scan (3D surface area). OCA projection onto the occlusal plane (2D area) was also computed, resulting in a total of 18 different OCA evaluations per patient.
Results
MP was lower in patients with malocclusion than in individuals with normal occlusion (X50 mean 5.35 vs. 4.62). The 18 mean OCAs ranged from 11 to 852 mm 2 . In subjects with normal occlusion, strong correlations were shown for interocclusal distances between 150 and 300 μm combined with 3D projection ( r < −0.7). For patients with malocclusion, no significant correlations were identified.
Conclusions
OCA appears a suitable indicator of MP in individuals with normal occlusion, but not in patients with malocclusion, where other factors seem more determinant.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Prosthodontics, University of Heidelberg, Heidelberg, Germany.
- Department of Oral and Maxillofacial Surgery, University of Heidelberg, Heidelberg, Germany.
- Department of Prosthetic Dentistry, Medical University Innsbruck, Innsbruck, Austria.
- Department of Orthodontics, University of Heidelberg, Heidelberg, Germany.
ORCID-Profile: Christopher Herpel
Zitieren
APA
Vortkamp, P., Rues, S., Räther, S., Eberhard, L., Rößler, A., Bouffleur, F., Kühle, R., Schwindling, F. S., Rammelsberg, P., Roser, C. J., & Herpel, C. (2025). Digital Occlusal Contact Area Indicates Masticatory Performance for Normal Occlusion, but Not for Malocclusion. Journal of Oral Rehabilitation. https://doi.org/10.1111/joor.14002
Vancouver
Vortkamp P, Rues S, Räther S, Eberhard L, Rößler A, Bouffleur F, et al. Digital Occlusal Contact Area Indicates Masticatory Performance for Normal Occlusion, but Not for Malocclusion. Journal of Oral Rehabilitation. 2025. doi:10.1111/joor.14002
BibTeX
@article{Vortkamp2025,
author = {Vortkamp, Paulina and Rues, Stefan and Räther, Sven and Eberhard, Lydia and Rößler, Alexander and Bouffleur, Frederic and Kühle, Reinald and Schwindling, Franz Sebastian and Rammelsberg, Peter and Roser, Christoph J and Herpel, Christopher},
title = {Digital Occlusal Contact Area Indicates Masticatory Performance for Normal Occlusion, but Not for Malocclusion},
journal = {Journal of Oral Rehabilitation},
year = {2025},
doi = {10.1111/joor.14002}
}
EUVIMED