Reduction of sleep bruxism events according to contingent electrical stimulus intensity
Journal of Oral Rehabilitation · 2024
DOI: 10.1111/joor.13763 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Oral Rehabilitation, 2024. Verfasst von Shigehito Kawahara und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Geriatric Dentistry, Osaka Dental University, Osaka, Japan. Hauptthemen laut MEDLINE: Sleep Bruxism, Electromyography, Electric Stimulation Therapy. Die Arbeit nennt 32 Literaturangaben.
Abstract (Originalsprache)
Background
Although biofeedback with contingent electrical stimulation (CES) has demonstrated the reduction effect on sleep bruxism (SB), the relationship between the actual applied CES intensity and efficacy remains uncertain.
Objective
This study aimed to investigate whether the reduction of bruxism events and jaw muscle symptoms could vary according to the intensity of CES and in probable sleep bruxers.
Methods
Twenty probable sleep bruxers were initially screened for bruxer confirmation based on a 2‐week recording of SB events with a portable electromyography recorder (BUTLER®GrindCare®, GC4). A 3‐week recording was conducted without CES using a GC4, followed by another 3‐week recording with CES. At baseline and before and after the CES (+) session, clinical muscle symptoms were assessed using a 0–10 numerical rating scale (NRS). The relationships between the actual applied CES intensity and the number of SB events/hour, as well as the NRS of clinical muscle symptoms, were analysed.
Results
The actual applied CES intensity was positively correlated with the reduction rate of the number of SB events/hour ( R = .643, p = .002), as well as with the reduction rate of NRS for pain, unpleasantness, fatigue, tension and stiffness ( R > .500, p < .011).
Conclusion
Higher CES elicited a more robust reduction in SB events and clinical muscle symptoms, in probable bruxers. Prior to selecting CES biofeedback as a management option for SB, it would be beneficial to assess the tolerance threshold of CES in each bruxer in order to predict the effectiveness of CES in probable sleep bruxers.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Geriatric Dentistry, Osaka Dental University, Osaka, Japan.
- Department of Oral Health Sciences, Faculty of Health Sciences, Osaka Dental University, Osaka, Japan.
ORCID-Profile: Akiko Shimada
Zitieren
APA
Kawahara, S., Kusunoki, T., Arikawa, K., Inoue, T., Kawamoto, A., Takahashi, K., & Shimada, A. (2024). Reduction of sleep bruxism events according to contingent electrical stimulus intensity. Journal of Oral Rehabilitation. https://doi.org/10.1111/joor.13763
Vancouver
Kawahara S, Kusunoki T, Arikawa K, Inoue T, Kawamoto A, Takahashi K, et al. Reduction of sleep bruxism events according to contingent electrical stimulus intensity. Journal of Oral Rehabilitation. 2024. doi:10.1111/joor.13763
BibTeX
@article{Kawahara2024,
author = {Kawahara, Shigehito and Kusunoki, Takayuki and Arikawa, Kaori and Inoue, Taro and Kawamoto, Akiyo and Takahashi, Kazuya and Shimada, Akiko},
title = {Reduction of sleep bruxism events according to contingent electrical stimulus intensity},
journal = {Journal of Oral Rehabilitation},
year = {2024},
doi = {10.1111/joor.13763}
}
EUVIMED