EUVIMEDEUVIMED entdecken
FallberichtOpen Access · CC BY-NC 4.0

Residual Oil‐Based Contrast Medium Mimicking a Metallic Foreign Body After Cesarean Section: Diagnostic Value of AI ‐Assisted 3D CT Analysis and Prenatal MRI

Mizuho Fukuda, Kyosuke Kagami, Iwao Yasoshima, Takashi Iizuka iD, Saya Igarashi, Kaoru Abiko

Journal of Obstetrics and Gynaecology Research · 2026

DOI: 10.1111/jog.70203 ↗

Kurz gefasst

Fallbericht in der Zeitschrift Journal of Obstetrics and Gynaecology Research, 2026. Verfasst von Mizuho Fukuda und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Obstetrics and Gynecology, Graduate School of Medical Sciences, Kanazawa University, Kanazawa, Ishikawa, Japan. Hauptthemen laut MEDLINE: Contrast Media, Magnetic Resonance Imaging, Tomography, X-Ray Computed, Cesarean Section. Die Arbeit nennt 14 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

A 36‐year‐old woman underwent an elective cesarean section at 37 weeks of gestation. A postoperative abdominal X‐ray unexpectedly revealed a 20 mm hyperattenuating pelvic lesion. Computed tomography (CT) demonstrated a dense structure exceeding 3000 Hounsfield units with metallic‐like artifacts, suggesting a retained metallic object. Intraoperative video review and instrument count confirmed no missing items. Three‐dimensional CT reconstruction and open‐source artificial intelligence (AI)–based shape analysis found no similarity to metallic instruments. Review of the patient's history revealed prior hysterosalpingography with oil‐based iodinated contrast medium. Retrospective assessment of prenatal magnetic resonance imaging (MRI) showed a cystic lesion with high signal intensity on T 1 ‐ and T 2 ‐weighted images, with signal suppression on fat‐suppressed T 1 ‐weighted imaging, consistent with fatty components. The lesion was diagnosed as a pseudocyst due to residual contrast medium. This case demonstrates that oil‐based contrast can mimic metallic density, and that AI‐assisted three‐dimensional CT and MRI review can prevent unnecessary reoperation.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Contrast MediaMagnetic Resonance ImagingTomography, X-Ray ComputedCesarean SectionForeign BodiesHumansFemaleAdultPregnancyArtificial IntelligenceImaging, Three-DimensionalPrenatal Diagnosis

Stichwörter der Autor:innen

artificial intelligencecesarean sectioncomputed tomographycontrast mediamagnetic resonance imaging

Substanzen

Contrast Media

Autor:innen und Institutionen

  • Department of Obstetrics and Gynecology, Graduate School of Medical Sciences, Kanazawa University, Kanazawa, Ishikawa, Japan.
  • Department of Radiology, Kanazawa University Graduate School of Medical Sciences, Kanazawa University, Kanazawa, Ishikawa, Japan.

ORCID-Profile: Takashi Iizuka

Zitieren

APA

Fukuda, M., Kagami, K., Yasoshima, I., Iizuka, T., Igarashi, S., & Abiko, K. (2026). Residual Oil‐Based Contrast Medium Mimicking a Metallic Foreign Body After Cesarean Section: Diagnostic Value of AI ‐Assisted 3D CT Analysis and Prenatal MRI. Journal of Obstetrics and Gynaecology Research. https://doi.org/10.1111/jog.70203

Vancouver

Fukuda M, Kagami K, Yasoshima I, Iizuka T, Igarashi S, Abiko K. Residual Oil‐Based Contrast Medium Mimicking a Metallic Foreign Body After Cesarean Section: Diagnostic Value of AI ‐Assisted 3D CT Analysis and Prenatal MRI. Journal of Obstetrics and Gynaecology Research. 2026. doi:10.1111/jog.70203

BibTeX
@article{Fukuda2026,
  author = {Fukuda, Mizuho and Kagami, Kyosuke and Yasoshima, Iwao and Iizuka, Takashi and Igarashi, Saya and Abiko, Kaoru},
  title = {Residual Oil‐Based Contrast Medium Mimicking a Metallic Foreign Body After Cesarean Section: Diagnostic Value of AI ‐Assisted 3D CT Analysis and Prenatal MRI},
  journal = {Journal of Obstetrics and Gynaecology Research},
  year = {2026},
  doi = {10.1111/jog.70203}
}
Kostenlos starten →