Residual Oil‐Based Contrast Medium Mimicking a Metallic Foreign Body After Cesarean Section: Diagnostic Value of AI ‐Assisted 3D CT Analysis and Prenatal MRI
Journal of Obstetrics and Gynaecology Research · 2026
DOI: 10.1111/jog.70203 ↗Kurz gefasst
Fallbericht in der Zeitschrift Journal of Obstetrics and Gynaecology Research, 2026. Verfasst von Mizuho Fukuda und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Obstetrics and Gynecology, Graduate School of Medical Sciences, Kanazawa University, Kanazawa, Ishikawa, Japan. Hauptthemen laut MEDLINE: Contrast Media, Magnetic Resonance Imaging, Tomography, X-Ray Computed, Cesarean Section. Die Arbeit nennt 14 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0).
Abstract (Originalsprache)
A 36‐year‐old woman underwent an elective cesarean section at 37 weeks of gestation. A postoperative abdominal X‐ray unexpectedly revealed a 20 mm hyperattenuating pelvic lesion. Computed tomography (CT) demonstrated a dense structure exceeding 3000 Hounsfield units with metallic‐like artifacts, suggesting a retained metallic object. Intraoperative video review and instrument count confirmed no missing items. Three‐dimensional CT reconstruction and open‐source artificial intelligence (AI)–based shape analysis found no similarity to metallic instruments. Review of the patient's history revealed prior hysterosalpingography with oil‐based iodinated contrast medium. Retrospective assessment of prenatal magnetic resonance imaging (MRI) showed a cystic lesion with high signal intensity on T 1 ‐ and T 2 ‐weighted images, with signal suppression on fat‐suppressed T 1 ‐weighted imaging, consistent with fatty components. The lesion was diagnosed as a pseudocyst due to residual contrast medium. This case demonstrates that oil‐based contrast can mimic metallic density, and that AI‐assisted three‐dimensional CT and MRI review can prevent unnecessary reoperation.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Obstetrics and Gynecology, Graduate School of Medical Sciences, Kanazawa University, Kanazawa, Ishikawa, Japan.
- Department of Radiology, Kanazawa University Graduate School of Medical Sciences, Kanazawa University, Kanazawa, Ishikawa, Japan.
ORCID-Profile: Takashi Iizuka
Zitieren
APA
Fukuda, M., Kagami, K., Yasoshima, I., Iizuka, T., Igarashi, S., & Abiko, K. (2026). Residual Oil‐Based Contrast Medium Mimicking a Metallic Foreign Body After Cesarean Section: Diagnostic Value of AI ‐Assisted 3D CT Analysis and Prenatal MRI. Journal of Obstetrics and Gynaecology Research. https://doi.org/10.1111/jog.70203
Vancouver
Fukuda M, Kagami K, Yasoshima I, Iizuka T, Igarashi S, Abiko K. Residual Oil‐Based Contrast Medium Mimicking a Metallic Foreign Body After Cesarean Section: Diagnostic Value of AI ‐Assisted 3D CT Analysis and Prenatal MRI. Journal of Obstetrics and Gynaecology Research. 2026. doi:10.1111/jog.70203