Effectiveness of an articulating laparoscopic needle holder for cesarean scar defect repair
Journal of Obstetrics and Gynaecology Research · 2024
DOI: 10.1111/jog.15938 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Obstetrics and Gynaecology Research, 2024. Verfasst von Yuri Nobuta und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Obstetrics and Gynecology, Shiga University of Medical Science, Otsu, Japan. Hauptthemen laut MEDLINE: Cicatrix, Laparoscopy, Cesarean Section. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 20 Literaturangaben.
Abstract (Originalsprache)
Aim
To evaluate the efficacy of an articulating laparoscopic needle holder in laparoscopic surgery for cesarean scar defect.
Methods
We performed a retrospective case–control study at the Shiga University of Medical Science. Patients who underwent laparoscopic uterine scar repair were divided into an articulating laparoscopic needle holder (ArtiSential®) group and a rigid needle holder (conventional) group to compare the suture and total operative times. Uterine myometrial suturing involves a double‐layer interrupted suture, including a modified Gambee suture for the first layer. We measured the residual myometrial thickness using magnetic resonance imaging preoperatively and at 3 months postoperatively.
Results
Both groups comprised 10 patients each. The time per stitch for the first and second layers was significantly shorter in the ArtiSential group than in the conventional group (median 208 s vs. 403 s, p < 0.0001 and median 17 s vs. 29 s; p < 0.0001, respectively). The total operating time was significantly shorter in the ArtiSential group (mean 188 min vs. 240 min, p = 0.0015). The postoperative residual myometrial thickness (mean 9.1 mm in the ArtiSential group and 9.6 mm in the conventional group) was significantly higher than the preoperative residual myometrial thickness (mean 1.6 mm in the ArtiSential group and 1.6 mm in the conventional group) ( p < 0.0001 in both groups).
Conclusions
An articulating needle holder is useful in laparoscopic surgery for cesarean scar defect, especially when a modified Gambee suture is required.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Obstetrics and Gynecology, Shiga University of Medical Science, Otsu, Japan.
ORCID-Profile: Yuri Nobuta, Shunichiro Tsuji, Tsukuru Amano
Zitieren
APA
Nobuta, Y., Tsuji, S., Nakamura, A., Yoneoka, Y., Ogawa, C., Amano, T., & Murakami, T. (2024). Effectiveness of an articulating laparoscopic needle holder for cesarean scar defect repair. Journal of Obstetrics and Gynaecology Research. https://doi.org/10.1111/jog.15938
Vancouver
Nobuta Y, Tsuji S, Nakamura A, Yoneoka Y, Ogawa C, Amano T, et al. Effectiveness of an articulating laparoscopic needle holder for cesarean scar defect repair. Journal of Obstetrics and Gynaecology Research. 2024. doi:10.1111/jog.15938
BibTeX
@article{Nobuta2024,
author = {Nobuta, Yuri and Tsuji, Shunichiro and Nakamura, Akiko and Yoneoka, Yutaka and Ogawa, Chiemi and Amano, Tsukuru and Murakami, Takashi},
title = {Effectiveness of an articulating laparoscopic needle holder for cesarean scar defect repair},
journal = {Journal of Obstetrics and Gynaecology Research},
year = {2024},
doi = {10.1111/jog.15938}
}
EUVIMED