The value of ultrasound parameters in predicting the efficacy of transabdominal ultrasound‐guided suction curettage alone in the treatment of cesarean scar pregnancy
Journal of Obstetrics and Gynaecology Research · 2024
DOI: 10.1111/jog.15927 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Obstetrics and Gynaecology Research, 2024. Verfasst von Chunqiao Zhou und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Ultrasonography, Maternity and Child Health Care of Guangxi Zhuang Autonomous Region, Nanning, China. Hauptthemen laut MEDLINE: Cicatrix, Cesarean Section, Pregnancy, Ectopic, Vacuum Curettage. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 26 Literaturangaben. Gefördert von: Guangxi Key Research and Development Program.
Abstract (Originalsprache)
Objective
To investigate the value of ultrasound parameters in assessing the efficacy of transabdominal ultrasound (TAUS)‐guided suction curettage alone for cesarean scar pregnancy (CSP).
Methods
Secondary retrospective analysis of a prospective study consisted of 137 women diagnosed with CSP who were performed TAUS‐guided suction curettage alone for the first time at Maternity and Child Health Care of Guangxi Zhuang Autonomous Region in China. Prior to surgery, an ultrasound examination was conducted. Based on the need for secondary intervention, the patients were categorized into failure group and success group, and the predictive factors for failure of TAUS‐guided suction curettage alone were analyzed.
Results
Multivariate logistic regression showed that maximum diameter of the gestational sac>29 mm (odds ratio [OR] = 4.043, 95% CI: 1.100–14.862), residual myometrium thickness ≤1.8 mm (OR = 3.719, 95% CI: 1.148–12.048) and chorionic villi thickness at the scar >4.7 mm (OR = 15.327, 95% CI: 4.617–50.881) were independent predictors of failure in TAUS‐guided suction curettage alone for CSP. Furthermore, the logistic regression model that was jointly constructed by these three predictors demonstrated an area under the curve, sensitivity, specificity, and Youden index of 0.913, 0.912, 0.864, and 0.776, respectively.
Conclusion
The maximum diameter of the gestational sac, residual myometrium thickness, and chorionic villi thickness at the scar has certain predictive efficacy of TAUS‐guided suction curettage alone for CSP. Nevertheless, it is more valuable to apply the model of this study, composed of the three ultrasound parameters, for this prediction purpose.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Ultrasonography, Maternity and Child Health Care of Guangxi Zhuang Autonomous Region, Nanning, China.
ORCID-Profile: Chunqiao Zhou
Förderung
- Guangxi Key Research and Development Program
Zitieren
APA
Zhou, C., Li, X., Mo, Y., & Wei, F. (2024). The value of ultrasound parameters in predicting the efficacy of transabdominal ultrasound‐guided suction curettage alone in the treatment of cesarean scar pregnancy. Journal of Obstetrics and Gynaecology Research. https://doi.org/10.1111/jog.15927
Vancouver
Zhou C, Li X, Mo Y, Wei F. The value of ultrasound parameters in predicting the efficacy of transabdominal ultrasound‐guided suction curettage alone in the treatment of cesarean scar pregnancy. Journal of Obstetrics and Gynaecology Research. 2024. doi:10.1111/jog.15927
BibTeX
@article{Zhou2024,
author = {Zhou, Chunqiao and Li, Xinyan and Mo, Yu'ning and Wei, Fangtao},
title = {The value of ultrasound parameters in predicting the efficacy of transabdominal ultrasound‐guided suction curettage alone in the treatment of cesarean scar pregnancy},
journal = {Journal of Obstetrics and Gynaecology Research},
year = {2024},
doi = {10.1111/jog.15927}
}
EUVIMED